Cheng‐Chi Tai

Prof. Cheng‐Chi Tai

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in Energy Conversion and Management
Verified
Journal Article
Closed access
CYCheng-En Ye
Cheng-En Ye
CTCheng‐Chi Tai
Cheng‐Chi Tai
Yu-Pei HuangYu-Pei Huang
Yu-Pei Huang
JCJun-Jia Chen
Jun-Jia Chen

23 March 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LKLung-Chih Kuo
Lung-Chih Kuo
CTCheng‐Chi Tai
Cheng‐Chi Tai
This study proposes an automatic image water-level measurement system using a single camera. The inverse perspective mapping (IPM) technology is used to rectify an image to improve deviations because the optical axis of the camera and staff gauge are not orthogonal, causing a perspective distortion in the real environment. The initial position of the current watermark is first determined from the staff gauge’s image by applying basic digital image-processing technology. The system uses the image histogram of staff gauge’s region of interest to provide a reference region for determining accurate water levels from the preliminary watermark position. Furthermore, the proposed system can correctly and automatically determine the current water-level elevation by establishing the control points to convert the pixel distance to the real-world distance as well as through the setting of the reference water-level elevation. The images are shifted because of camera vibration, which will also shift the waterline coordinates. To prevent the image shift due to camera vibration from interfering with the accuracy of water-level measurement, we used the normalized cross-correlation technology with the proposed camera-vibration calibration scheme for removing the impact. The proposed distance calibration module further optimizes the results of the images rectified using the IPM technology. The suggested automatic water-level measurement system can improve the traditional linear interpolation approach by >90%, and the deviation value of the real water level is <0.5 cm, which is ideal for water-level measurement in confined spaces according to experimental results.

24 June 2023 in Energies
Verified
Journal Article
Open access
PDF file
CYCheng-En Ye
Cheng-En Ye
CTCheng‐Chi Tai
Cheng‐Chi Tai
Yu-Pei HuangYu-Pei Huang
Yu-Pei Huang
This paper presents a novel modified Complementary SuDoKu puzzle (MC-SDKP) topology for the static reconfiguration of photovoltaic (PV) arrays. It was developed with the aim of enhancing the power output of a PV array which is exposed to partially shaded conditions (PSCs). To disperse patterns of both center shading and corner shading, the MC-SDKP technique modified and combined the Optimal SDKP and the Complementary SDKP (C-SDKP) topologies. An 8 × 8 PV array configured with the MC-SDKP topology was exposed to nine different shading patterns, and its performance was compared with that of the other four topologies. The results of the performance evaluation confirmed that, when configured according to the MC-SDKP, the PV array produced the highest average power output among all five topologies, with a 15.07% higher output on average than the total-cross tied. The PV array with the MC-SDKP topology also exhibited the lowest average power loss (1.34%). This study clearly established the effectiveness of the MC-SDKP topology at mitigating the effects of both center and corner shading. The advantages of the MC-SDKP reconfiguration technique are: an increase in extracted power, a reduction in current mismatch losses, an improvement in shade dispersion under conditions of center shading, and good scalability.

17 December 2019 in IEEE Access
Verified
Journal Article
Open access
BPBo Peng
Bo Peng
CLChing-Hsing Luo
Ching-Hsing Luo
WCWai Yeh Chan
Wai Yeh Chan
MSMeng-Dar Shieh
Meng-Dar Shieh
CSChun-Jen Su
Chun-Jen Su
CTCheng‐Chi Tai
Cheng‐Chi Tai
This study proposes the prototype of a wrist pulse acquisition device with three-dimensional pulse image (3DPI) obtained at the radial artery. The proposed prototype is designed with mechanical and electronic circuit hardware as well as the control and data acquisition software to have fourteen degrees of movement freedom against the sophisticated geometry of the wrist radial artery for accurate pulse-taking. Three robot fingers with nine degrees of movement freedom and a wrist fixer with two degrees of rotation freedom and one degree of manual movement freedom are designed to mimic the fine pulse-taking skill of a Chinese medicine physician. The customer-designed array sensors with 5×5-1 sensing elements in an array are attached on the robot fingertips to get 3DPI with spatial information for direct translation of pulse feeling patterns in Chinese medicine texts, in addition to being compatible with 1D pulse wave analysis. To check reliability of the prototype, adopted is SphygmoCor with pulse data correlation. Consequently, the prototype passes safety tests and has high correlation of pulse data (waveform and peripheral augmented index) with those obtained by SphygmoCor. The automatic multi-depth pulse-taking with robot fingers attached array sensors on their tips can get acceptably repeatable pulse data with coefficient of variation less than 10%. By simultaneous pulse-taking at Cun-Guan-Chi positions, 3DPIs demonstrate great different stereoscopic waveshapes against almost unchanged single temporal pulse waveshape. Hence, the proposed prototype may be a useful tool to perform array pulse-taking for Chinese medicine pulse diagnosis and pulse wave analysis for cardiovascular examination.

3 July 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
CCChien-Chang Chen
Chien-Chang Chen
CTCheng‐Chi Tai
Cheng‐Chi Tai
CLChan-Liang Liu
Chan-Liang Liu
A microwave nondestructive evaluation (NDE) microstrip sensor operating in C-band (from 7 GHz to 8 GHz) to measure different thickness of the copper clad laminate (CCL). The study disclosed herein was developed and designed to perform noncontact precision measurement based on the reflection of electromagnetic waves. The different electromagnetic field losses of materials under test (MUT) with varying surface copper thicknesses, the changes in electromagnetic field losses can be observed through the S11 reflection coefficient to calculate the surface copper thickness of the MUT. The microwave microstrip sensor module was designed and manufactured to receive reflected electromagnetic waves. The sensor is sensitive and can identify copper layer variations effectively. Using non-contact measurement, the sensor achieves a sensitivity and resolution of 0.1 μm at a standoff distance of 5.5 mm between the sensor and the MUT. The experimental results demonstrate that when measuring the copper foil thickness of CCL, the measurement error rate percentage is within 1% deviation compared to the four-point probe method. The study is integrated an algorithm for converting the real time online measurement results of reflected electromagnetic wave signals into the thickness of a thin copper layer, achieving the same level of measurement precision as the contact-based four-point probe measurement.

28 May 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CCChia-Jung Chang
Chia-Jung Chang
CTCheng‐Chi Tai
Cheng‐Chi Tai
FLFang-Wei Lin
Fang-Wei Lin
CKChung-Ching Kuo
Chung-Ching Kuo
CHChia-Ming Hung
Chia-Ming Hung
This paper presents a newly developed flexible laminated copper coil (FLC) for electromagnetic thermotherapy that has several advantages over traditional hard copper coils. We study the effect of pitch (the distance between coil turns) on the heating performance of the proposed FLC coil. The flexible coil can be wound into different shapes for various purposes. However, the output power of the heating system can be substantiality affected by the coil inductance. This study is aimed toward reducing coil inductance by changing the original flexible coil diameter and pitch in order to enhance the output power of a high-frequency machine, improve treatment, and meet the actual heating requirements. The results of the experiments show that the temperature is six times better when using the flexible coil as compared to when using the traditional hard copper coil, where adjusting the coil pitch can increase the needle temperature by a maximum of 48.3°C in pork liver tissue. In addition, this study simulates distribution of the magnetic field of the flexible coil via a finite element analysis and explores the coil design and heating effect of metal needle heating and liver tissue ablation. The improved features of this proposed method are threefold: (1) The flexible coil can be used to treat different zones of the human body. (2) The flexible coil exhibits better heating performance than a hard copper coil. (3) The coil inductance is lowered, and power is improved, which in turn, leads to better treatment and meets the actual heating requirements.