J. Rahm

J. Rahm

Auto-generated profile, based on publicly available information

J. Rahm

Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2021 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
RLR. Lange
R. Lange
NHN. Huntemann
N. Huntemann
JRJ. M. Rahm
J. M. Rahm
CSC. Sanner
C. Sanner
HSH. Shao
H. Shao
EPE. Peik
E. Peik
We compare two optical clocks based on the S21/2(F=0)→D23/2(F=2) electric quadrupole (E2) and the S21/2(F=0)→F27/2(F=3) electric octupole (E3) transition of Yb171+ and measure the frequency ratio νE3/νE2=0.932829404530965376(32), improving upon previous measurements by an order of magnitude. Using two caesium fountain clocks, we find νE3=642121496772645.10(8)  Hz, the most accurate determination of an optical transition frequency to date. Repeated measurements of both quantities over several years are analyzed for potential violations of local position invariance. We improve by factors of about 20 and 2 the limits for fractional temporal variations of the fine structure constant α to 1.0(1.1)×10−18/yr and of the proton-to-electron mass ratio μ to −8(36)×10−18/yr. Using the annual variation of the Sun’s gravitational potential at Earth Φ, we improve limits for a potential coupling of both constants to gravity, (c2/α)(dα/dΦ)=14(11)×10−9 and (c2/μ)(dμ/dΦ)=7(45)×10−8.

11 August 2020 in Physical Review Research
Verified
Journal Article
Open access
PDF file
RSR. Schwarz
R. Schwarz
SDS. Dörscher
S. Dörscher
AAA. Al-Masoudi
A. Al-Masoudi
EBE. Benkler
E. Benkler
TLT. Legero
T. Legero
CLC. Lisdat
C. Lisdat
We report on a series of 42 measurements of the transition frequency of the 429 THz (5s2) S01–(5s5p) P03 line in Sr87 taken over three years from 2017 to 2019. They were performed at the Physikalisch-Technische Bundesanstalt (PTB) between the laboratory strontium lattice clock and the primary caesium fountain clocks CSF1 and CSF2. The length of each individual measurement run has been extended by use of a hydrogen maser as a flywheel to improve the statistical uncertainty given by the Cs clocks. We determine an averaged transition frequency of 429228004229873.00(0.07) Hz with 1.5×10−16 fractional uncertainty at the limit of the current realization of the unit hertz. Analysis of the data provides an improved limit on the coupling of the gravitational potential of the Sun to the proton-electron mass ratio μ and confirms the limits on the temporal drift of μ.

16 January 2025 in Physical Review Letters
Verified
Journal Article
Open access
HHH. N. Hausser
H. N. Hausser
JKJ. Keller
J. Keller
TNT. Nordmann
T. Nordmann
NBN. M. Bhatt
N. M. Bhatt
JKJ. Kiethe
J. Kiethe
TMT. E. Mehlstäubler
T. E. Mehlstäubler
We present a scalable mixed-species Coulomb crystal clock based on the S 0 1 ↔ P 3 0 transition in In + 115 . Yb + 172 ions are cotrapped and used for sympathetic cooling. Reproducible interrogation conditions for mixed-species Coulomb crystals are ensured by a conditional preparation sequence with permutation control. We demonstrate clock operation with a 1 In + − 3 Yb + crystal, achieving a relative systematic uncertainty of 2.5 × 10 − 18 and a relative frequency instability of 1.6 × 10 − 15 / τ / 1 s . We report on absolute frequency measurements with an uncertainty of 1.3 × 10 − 16 and optical frequency comparisons with clocks based on Yb + 171 ( E 3 ) and Sr 87 . With a fractional uncertainty of 4.4 × 10 − 18 , the former is—to our knowledge—the most accurate frequency ratio value reported to date. For the In + 115 / Sr 87 ratio, we improve upon the best previous measurement by more than an order of magnitude. We also demonstrate operation with four In + 115 clock ions, which reduces the instability to 9.2 × 10 − 16 / τ / 1 s .

27 October 2025 in Physical Review Applied
Verified
Journal Article
Open access
TLT. Lindvall
T. Lindvall
TFT. Fordell
T. Fordell
KHK.J. Hanhijärvi
K.J. Hanhijärvi
MDM. Doležal
M. Doležal
JRJ. Rahm
J. Rahm
AWA.E. Wallin
A.E. Wallin
We report on a 88 Sr + single-ion optical clock with an estimated fractional systematic uncertainty of 7.9× 10 − 19 . The low uncertainty is enabled by small rf losses, a thorough evaluation of the blackbody-radiation temperature, and our recent measurement of the differential polarizability. A detailed uncertainty evaluation is presented. We also report on two absolute frequency measurements: one against a remote cesium fountain clock, and one against International Atomic Time (TAI). The former lasted 12 d and resulted in a frequency value of 444 779 044 095 485.49(15) Hz. The latter spanned 10 months with monthly optical-clock uptimes between 68% and 99%, and yielded a frequency value of 444 779 044 095 485.373(44) Hz. With a fractional uncertainty of 9.8× 10 − 17 , it is, to our knowledge, the most accurate optical frequency measurement reported to date. Both frequency values are in agreement with other recent measurements, providing further evidence that the 2021 CIPM recommended frequency value is too high by 1.6 times its uncertainty.

28 October 2025 in Quantum Science and Technology
Verified
Journal Article
Open access
INI Nosske
I Nosske
CVC Vishwakarma
C Vishwakarma
TLT Lücke
T Lücke
JRJ Rahm
J Rahm
NPNavraj Poudel
Navraj Poudel
CLC Lisdat
C Lisdat
We describe a transportable optical lattice clock based on the 1 S 0 → 3 P 0 transition of lattice-trapped 87 Sr atoms with a total systematic uncertainty of 2.1 × 10 − 18 . The blackbody radiation shift, which is the leading systematic effect in many strontium lattice clocks, is controlled at the level of 4.0 × 10 − 19 , as the atoms are interrogated inside a well-characterised, cold thermal shield. Using a transportable clock laser, the clock reaches a frequency instability of about 5 × 10 − 16 / τ / s , which enables fast reevaluations of systematic effects. By comparing this clock to the primary caesium fountain clocks CSF1 and CSF2 at Physikalisch-Technische Bundesanstalt, we measure the clock transition frequency with a fractional uncertainty of 1.9 × 10 − 16 , in agreement with previous results. The clock was successfully transported and operated at different locations. It holds the potential to be used for geodetic measurements with centimetre-level or better height resolution and for accurate inter-institute frequency comparisons.

18 December 2020 in Physical Review E
Verified
Journal Article
Closed access
PDF file
WBW. Y. Baek
W. Y. Baek
TBT. Braunroth
T. Braunroth
LRL. de La Fuente Rosales
L. de La Fuente Rosales
JRJ. M. Rahm
J. M. Rahm
HRHans Rabus
Hans Rabus
The stopping power of liquid water was measured for carbon ions with energies in the Bragg peak region using the inverted Doppler shift attenuation method. Among the semiempirical data, the results of this work agree best with the data recommended in the Errata and Addendum of ICRU Report No. 73, which is based on an I value of 78 eV for water. The agreement was worse when the present results were compared to the newer recommendation of the ICRU published in ICRU Report No. 90. The srim code seems to slightly overestimate the stopping power of water for carbon ions above 3 MeV. A semiexperimental stopping power of water for α particles was derived from the present results using the theoretical ratio between the stopping powers of water for carbon ions and α particles computed by means of the casp code. These values agree well with the experimental data for α particles within the uncertainties.