We report on a 88 Sr + single-ion optical clock with an estimated fractional systematic uncertainty of 7.9× 10 − 19 . The low uncertainty is enabled by small rf losses, a thorough evaluation of the blackbody-radiation temperature, and our recent measurement of the differential polarizability. A detailed uncertainty evaluation is presented. We also report on two absolute frequency measurements: one against a remote cesium fountain clock, and one against International Atomic Time (TAI). The former lasted 12 d and resulted in a frequency value of 444 779 044 095 485.49(15) Hz. The latter spanned 10 months with monthly optical-clock uptimes between 68% and 99%, and yielded a frequency value of 444 779 044 095 485.373(44) Hz. With a fractional uncertainty of 9.8× 10 − 17 , it is, to our knowledge, the most accurate optical frequency measurement reported to date. Both frequency values are in agreement with other recent measurements, providing further evidence that the 2021 CIPM recommended frequency value is too high by 1.6 times its uncertainty.
We present a compact bichromatic imaging system, located outside of the vacuum chamber of a trapped ion apparatus that collects the fluorescence of 230.6 and 369.5 nm photons simultaneously on a shared electron-multiplying charge-coupled device (EMCCD) camera. The system contains two lens doublets, consisting of a sphere and an asphere. They provide a numerical aperture of 0.45 and 0.40 at 230.6 and 369.5 nm, respectively, and enable spatially resolved state detection with a large field of view of 300 μm for long 115In+/172Yb+ Coulomb crystals. Instead of diffraction-limited imaging for one wavelength, the focus in this system is on simultaneous single-ion resolved imaging of both species over a large field, with special attention to the deep UV wavelength (230.6 nm) and the low scattering rate of In+ ions. The introduced concept is applicable to other dual-species applications.
In our paper,1 the rf amplitudes in Table IX are a factor 2 too large to fit the published secular frequencies. Consequently, the temperature increases at senso