24 October 2017 in Eastern-European Journal of Enterprise Technologies
Generalized models have been built of one-, two-, and three-mass vibration machines with a rectilinear translational motion of platforms and a vibration exciter in the form of a ball, a roller, or a pendulum auto-balancer.In the generalized model of a single-mass vibration machine, the platform relies on an elastic-viscous support with the guides enabling the platform’s rectilinear translational motion. A passive auto-balancer is installed on the platform.In the generalized models of two- and three-mass vibration machines, each platform relies on a fixed external elastic-viscous support with the platforms coupled in pairs by elastic-viscous inner supports. The guides allow the platforms to move rectilinearly translationally. A passive auto-balancer is installed on one of the platforms.We have derived differential equations of the motion of vibration machines. The equations are reduced to the form that is independent of the type of an auto-balancer.The models of particular one-, two- and three-mass vibration machines can be obtained from the generalized models by selecting a specific type of the auto-balancer.The models of particular two-mass vibration machines can also be obtained from the corresponding generalized model by rejecting one of the external elastic-viscous supports.The models of particular three-mass vibration machines can also be derived from the corresponding generalized model by rejecting:– one or two external elastic-viscous supports;– one of the three inner elastic-viscous supports;– one or two external elastic-viscous supports and one of the three inner elastic-viscous supports.The constructed models are applicable both for analytical studies into dynamics of the relevant vibration machines and for performing computational experiments.When employed in analytical studies, the models are designed to search for the established modes of a vibration machine motion, to determine conditions for their existence and stability
19 August 2015 in Eastern-European Journal of Enterprise Technologies
ВЯВладимир Владимирович Яцун
Владимир Владимирович Яцун
Method of excitation of dual frequency vibrations by passive autobalancers
21 February 2016 in Eastern-European Journal of Enterprise Technologies
ВЯВладимир Владимирович Яцун
Владимир Владимирович Яцун
The 3D model of the upgraded light-duty unbalanced-throw screen GIL 42 with the ball auto-balancer as the exciter of dual-frequency vibrations is developed. Key parameters that affect the stability of dual-frequency vibrations are identified. It is found that the fields of dual-frequency vibrations are relatively large, which allows changing the characteristics of dual-frequency vibrations by changing these parameters. The box mass increase reduces the lower vibration frequency. Herewith, the corrector weights automatically adjust to the box mass change. The mass increase of corrector weights directly increases the amplitude of slow vibrations of the box. The mass increase of the unbalance on the auto-balancer housing directly increases the amplitude of fast vibrations of the box. The rotor speed increase directly increases the speed of fast vibrations of the box. A number of parameters that affect the value of the amplitude of slow vibrations are identified. Since dual-frequency vibrations have two components, arising from the unbalance on the auto-balancer housing and corrector weights respectively, it was decided to examine each component separately. As a result, it is found that the auto-balancer operates as two independent vibration exciters: - the first is formed by corrector weights, and it excites slow vibrations of the box with the natural resonant frequency; - the second is formed by the unbalanced mass on the auto-balancer housing, and it excites fast vibrations of the box with the rotor speed.
30 June 2016 in Eastern-European Journal of Enterprise Technologies
Research into excitation of dual frequency vibrational-rotational vibrations of screen duct by ball-type auto-balancer
29 April 2017 in Eastern-European Journal of Enterprise Technologies
The conditions for the occurrence of auto-balancing for the rigid axisymmetric rotor on two isotropic elastic supports, balanced by any quantity of passive auto-balancers of any type, are defined. The empirical criterion for the occurrence of auto-balancing is applied. It is established that the dynamic auto-balancing of the rotor (in two or more correction planes by several passive auto-balancers) is possible only in the case of the long rotor. There can be any quantity of auto-balancers. The long rotor has two resonant rotational speeds. The auto-balancing occurs at above resonance speeds. The static auto-balancing of the rotor (in one correction plane) is possible at any quantity of auto-balancers in such cases. If the rotor is long, then it has two resonant speeds and one additional speed, located between the resonant ones. The auto-balancing occurs between the first resonant speed of rotor rotation and additional speed, and over the second resonant speed. If the rotor is spherical, then it has one resonant speed and the additional speed, which is higher than the resonant one. The auto-balancing occurs between the resonant and additional speeds. If the rotor is short, then the conditions for the occurrence of auto-balancing depend on the distance between the rotor center of mass and the correction plane. If this distance does not exceed the certain boundary size, then the rotor has the only resonant speed and the auto-balancing occurs at above resonance speeds. Otherwise, the rotor has one resonant and one additional speed, which is higher than the resonant one. The auto-balancing occurs between these speeds.The additional speed is due to the installation of the auto-balancers on the rotor. Upon transition to it, the behavior of auto-balancers changes. At slightly lower rotor rotational speeds, the auto-balancers reduce the rotor imbalance, and at slightly higher ones – increase it.
28 February 2017 in Eastern-European Journal of Enterprise Technologies
The study has revealed an influence of the parameters of corrective weights (balls and cylindrical rollers) in auto-balancers on the balancing capacity and the duration of the transition processes of auto-balancing in fast-rotating rotors. A compact analytical function has been obtained to determine the balancing capacity of an auto-balancer (for any quantity of corrective weights – balls or rollers), with a subsequent analysis thereof. It is shown that the process of approach of the auto-balancing can be accelerated if the auto-balancer contains at least three corrective weights. It has been proved that at a fixed radius of the corrective weights the highest balancing capacity of an auto-balancer is achieved when the corrective weights occupy nearly half of the racetrack. The study has revealed that it is technically incorrect to formulate a problem of finding a radius of the corrective weights that would maximize the balancing capacity of the auto-balancer. The statement implies that if it is a ball auto-balancer, the racetrack is a sphere, but if it is a roller-type balancer, the racetrack is a cylinder. This leads to a practically useless result, suggesting that the highest balancing capacity is achieved by auto-balancers with one corrective weight. Besides, with n≥5 for balls and n≥8 for rollers, there happens a false optimization, which consists in several corrective weights being “excess”. Their removal increases the balancing capacity of the auto-balancer. It is correct (from the engineering point of view) that the mathematical task is to optimize the balancing capacity of an auto-balancer. Herewith, it is taken into account that the racetrack of the auto-balancer is torus-shaped, which restricts the radius of the corrective weights from the top. It is shown that the balancing capacity of an automatic balancer can be maximized if in a fixed volume the corrective weights have the largest possible radius and occupy almost a half of the racetrack. The research on the duration of the transition processes for the smallest value has produced the following conclusions: – to accelerate the achieving auto-balancing, the corrective weights should occupy nearly half of the racetrack;– the shortest time of the auto-balancing is achieved with three balls or five cylindrical rollers.