15 July 2022 in Science Advances
The spatial resolution of magnetic resonance imaging (MRI) is limited by the width of Lorentzian point spread functions associated with the transverse relaxation rate 1/ T 2 * . Here, we show a different contrast mechanism in MRI by establishing RASER (radio-frequency amplification by stimulated emission of radiation) in imaged media. RASER imaging bursts emerge out of noise and without applying radio-frequency pulses when placing spins with sufficient population inversion in a weak magnetic field gradient. Small local differences in initial population inversion density can create stronger image contrast than conventional MRI. This different contrast mechanism is based on the cooperative nonlinear interaction between all slices. On the other hand, the cooperative nonlinear interaction gives rise to imaging artifacts, such as amplitude distortions and side lobes outside of the imaging domain. Contrast mechanism and artifacts are explored experimentally and predicted by simulations on the basis of a proposed RASER MRI theory.
15 August 2023 in Physical Review A
A nuclear-spin-based RASER (radio-frequency amplification by stimulated emission of radiation) is an ideal experimental system to explore nonlinear interaction phenomena of nuclear spins coupled via virtual photons to a resonator. This is due to the RASER being stable for several hours, allowing for extended observation of these phenomena. Nonlinear phenomena in multimode RASERs range from mode oscillations in synchrony, frequency shifts, frequency combs, period doublings, and even chaos. These phenomena are observed in a parahydrogen-pumped two-compartment proton RASER. In two independently pumped compartments, the separation in frequency space between the two RASER modes is precisely controlled with a magnetic field gradient. By controlling the mode separation, we can select the type of nonlinear phenomena observed. A key finding is that the ranges of mode separation where chaos and synchrony occur are very close together. The experimental results are supported by numerical simulations, based on two-mode RASER equations.
12 July 2024 in Angewandte Chemie International Edition
9 January 2026 in Chemical Communications
Enhancing NMR signals of urinary metabolites using SABRE hyperpolarization in an automated benchtop-scale setup.
12 July 2024 in Angewandte Chemie
28 January 2026 in Angewandte Chemie
Zusammenfassung: Die konventionelle Magnetresonanztomographie (MRT) basiert auf intensiven Radiofrequenzimpulsen (RF‐Impulsen) zur Anregung von Kernspins, und damit zur Erzeugung von NMR‐Signalen. Diese Impulse erfordern große, leistungsstarke RF‐Verstärker und verursachen Wärme im Gewebe, die aus Sicherheitsgründen minimiert werden muss. Dies stellt bei der Entwicklung von MRT‐Geräten mit immer höheren Feldstärken ein wachsendes Problem dar. Eine Alternative zur RF‐Impulsanregung ist die Selbstanregung von Kernspins mittels Radiofrequenzverstärkung durch stimulierte Emission von Strahlung (Radiofrequency Amplification by Stimulated Emission of Radiation, RASER), bei der die Kernspins ohne RF‐Anregung einen spontanen Übergang von einem energetischen Nichtgleichgewichtszustand in einen Grundzustand durchlaufen. In dieser Arbeit wird die Möglichkeit der Aufzeichnung von „schnellen“ Protonen‐RASER‐MRT‐Bildern von Pyrazin in geringer Konzentration (120 mM) demonstriert. In nur 78 ms werden Bilder mit großer Matrix (128x128 Pixel) bei 500 MHz (11,7 T) aufgenommen. Weiter wurde eine Zeitreihe von Bildern unter Verwendung eines einzelnen Bolus hyperpolarisierten (HP) Pyrazins aufgezeichnet, um die Machbarkeit einer dynamischen Verfolgung zu verdeutlichen. Der demonstrierte Ansatz ermöglicht die Aufzeichnung von MRT‐Scans ohne die Sende‐Empfänger‐Elektronik des MRT‐Scanners, was für tragbare MRT‐Geräte sowie für das aufstrebende Gebiet der hyperpolarisierten MRT, bei der z. B. HP Protonen ( 1 H), 129 Xe‐Gas oder HP 13 C‐markierte Biomoleküle als molekulare Tracer und Bildgebungsmittel verwendet werden, äußerst vorteilhaft ist.