14 April 2016 in IEEE Transactions on Power Systems
In some rural and sub-urban areas, the hosting capacity (HC) of low voltage networks is restricted by voltage limits. With local voltage control, photovoltaic generators can mitigate the voltage rise partly and, therefore, increase the HC. This paper investigates the effectiveness and general performance of different reactive and active power control concepts. It presents the findings of an extensive simulation-based investigation into the effectiveness of voltage rise mitigation, additional reactive power flows, network losses, and power curtailment. The two most common implementations of reactive power control have a similar effectiveness. The voltage rise can be compensated for by up to 25% and more than 60% for typical cable and overhead (OH) feeders, respectively. By additionally using active power curtailment of up to 3% of the annual yield, the HC can be increased by about 50% and 90% for the considered cable and OH feeder, respectively (purely rural feeders).
6 October 2021 in IEEE Open Access Journal of Power and Energy
In regions with high penetration of Distributed Energy Resources (DER), grid congestion is mostly caused by power feed-in of generators. In this context, conventional approaches for solving the grid congestion problems are Active Power Curtailment (APC) of DER and grid reinforcement. In the wake of increased DER generation, it is not only of interest how to obtain the grid reinforcement, but also how to consider APC during grid planning. The challenge of such grid planning is to determine the best combination of reinforcement and APC. We present a new grid planning method and use it to find the trade-off between APC and grid reinforcement in a case study of a High-Voltage (HV) grid with a future renewable energy scenario. We compare the proposed reinforcement method to two existing methods. With the combination of APC and grid reinforcement, the proposed method shows a decrease regarding the total expenditures.
21 October 2023 in IET Generation, Transmission & Distribution
A novel method is introduced to determine cost‐optimized active power curtailment (APC) of renewable energy sources (RES) considering weather‐dependent dynamic line rating (DLR). A new formulation of the security‐constrained optimal power flow (SC‐OPF) is developed and applied in a case study. The reduction of the required preventive APC in the case for secure grid operation due to the consideration of thermal inertia of overhead power lines is demonstrated. Considering thermal inertia allows relying on curative APC that is activated only after an situation occurs. The overhead power line temperature, calculated with the temperature‐dependent power flow (TDPF), acts as a new limit for line loading and releases unused transmission reserves. The TDPF algorithm is integrated in the open‐source Python library pandapower, providing access to it to the broader community. The power system can be utilized to a greater extent, with a reduced demand for congestion management.