In some rural and sub-urban areas, the hosting capacity (HC) of low voltage networks is restricted by voltage limits. With local voltage control, photovoltaic generators can mitigate the voltage rise partly and, therefore, increase the HC. This paper investigates the effectiveness and general performance of different reactive and active power control concepts. It presents the findings of an extensive simulation-based investigation into the effectiveness of voltage rise mitigation, additional reactive power flows, network losses, and power curtailment. The two most common implementations of reactive power control have a similar effectiveness. The voltage rise can be compensated for by up to 25% and more than 60% for typical cable and overhead (OH) feeders, respectively. By additionally using active power curtailment of up to 3% of the annual yield, the HC can be increased by about 50% and 90% for the considered cable and OH feeder, respectively (purely rural feeders).
The number of fluctuating distributed energy resources (DER) in electricity grids is continuously rising. Due to the lack of operational information on low-voltage (LV) networks, conservative assumptions are necessary to assess the connection of generators to the grid. This paper introduces the hosting capability (HC) as a measure to assess the amount of DER that can be integrated in LV-feeders. The HC of a feeder is the minimum amount of DER that can be hosted in a feeder without reinforcement needs for a given DER-scenario and for a given admissible voltage rise. The hosting capability assessment was performed on the entire LV-grid data of two Austrian Distribution System Operators (DSOs) with more than 36,000 LV-feeders. In total, 40 HC-scenarios were calculated with varying admissible voltage rise levels, DER-scenarios and reactive power control strategies. It turned out that only few feeder parameters such as the resistance at the end node and the lowest ampacity value of feeders show a high correlation with the calculated HC. Further, the impact of the DER-scenario on the share of voltage and loading constrained feeders is rather limited. The gathered results are suitable to validate equivalent LV-feeders models to perform integrated power flow studies on the transmission and distribution grids. Besides the results obtained for the network data of the two DSOs, a performant, modular and parallelizable tool has been developed to automatically analyze large LV network sets.
This paper presents the results of a parametric study aiming at investigating the impact of (ZIP) load models on power flow studies in distribution networks. In particular, the effect of varying the voltage levels on voltage drops, losses, peak demand and reactive power behavior are analyzed for a set of generic feeders generated automatically, showing significant differences between models.
This paper presents a novel concept for combining network and market or system service-orientated functions in grid storage systems. For this, a network service consisting in local phase balancing for power flows or voltages is considered. This service can be combined with further system or market - orientated services. A theoretical formulation of the converter set-points is provided for the use-case phase balancing together with active and/or reactive power provision and is illustrated with enlightening examples.