Paras R. Patel

Paras R. Patel

Auto-generated profile, based on publicly available information

Paras R. Patel

Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2012 in Nature Materials
Verified
Journal Article
Closed access
PDF file
TKTakashi Kozai
Takashi Kozai
NLNicholas B. Langhals
Nicholas B. Langhals
PPParas R. Patel
Paras R. Patel
XDXiaopei Deng
Xiaopei Deng
HZHuanan Zhang
Huanan Zhang
DKDaryl R. Kipke
Daryl R. Kipke

10 April 2007 in Neurology
Verified
Journal Article
Closed access
PDF file
GRG. D. Rabinovici
G. D. Rabinovici
AFA. J. Furst
A. J. Furst
JOJ. P. O'Neil
J. P. O'Neil
CRC. A. Racine
C. A. Racine
EME. C. Mormino
E. C. Mormino
WJW. J. Jagust
W. J. Jagust
Background: The PET tracer 11C-labeled Pittsburgh Compound-B (11C-PIB) specifically binds fibrillar amyloid-beta (Aβ) plaques and can be detected in Alzheimer disease (AD). We hypothesized that PET imaging with 11C-PIB would discriminate AD from frontotemporal lobar degeneration (FTLD), a non-Aβ dementia. Methods: Patients meeting research criteria for AD (n = 7) or FTLD (n = 12) and cognitively normal controls (n = 8) underwent PET imaging with 11C-PIB (patients and controls) and 18F-fluorodeoxyglucose (18F-FDG) (patients only). 11C-PIB whole brain and region of interest (ROI) distribution volume ratios (DVR) were calculated using Logan graphical analysis with cerebellum as a reference region. DVR images were visually rated by a blinded investigator as positive or negative for cortical 11C-PIB, and summed 18F-FDG images were rated as consistent with AD or FTLD. Results: All patients with AD (7/7) had positive 11C-PIB scans by visual inspection, while 8/12 patients with FTLD and 7/8 controls had negative scans. Of the four PIB-positive patients with FTLD, two had 18F-FDG scans that suggested AD, and two had 18F-FDG scans suggestive of FTLD. Mean DVRs were higher in AD than in FTLD in whole brain, lateral frontal, precuneus, and lateral temporal cortex (p < 0.05), while DVRs in FTLD did not significantly differ from controls. Conclusions: PET imaging with 11C-labeled Pittsburgh Compound-B (11C-PIB) helps discriminate Alzheimer disease (AD) from frontotemporal lobar degeneration (FTLD). Pathologic correlation is needed to determine whether patients with PIB-positive FTLD represent false positives, comorbid FTLD/AD pathology, or AD pathology mimicking an FTLD clinical syndrome.

2 June 2015 in Journal of Neural Engineering
Verified
Journal Article
Open access
PPParas R Patel
Paras R Patel
KNKyounghwan Na
Kyounghwan Na
HZHuanan Zhang
Huanan Zhang
TKTakashi Kozai
Takashi Kozai
NKNicholas A Kotov
Nicholas A Kotov
CCCynthia A Chestek
Cynthia A Chestek
Single carbon fiber electrodes (d = 8.4 μm) insulated with parylene-c and functionalized with pTS have been shown to record single unit activity but manual implantation of these devices with forceps can be difficult. Without an improvement in the insertion method any increase in the channel count by fabricating carbon fiber arrays would be impractical. In this study, we utilize a water soluble coating and structural backbones that allow us to create, implant, and record from fully functionalized arrays of carbon fibers with ∼150 μm pitch. Two approaches were tested for the insertion of carbon fiber arrays. The first method used a poly(ethylene glycol) (PEG) coating that temporarily stiffened the fibers while leaving a small portion at the tip exposed. The small exposed portion (500 μm-1 mm) readily penetrated the brain allowing for an insertion that did not require the handling of each fiber by forceps. The second method involved the fabrication of silicon support structures with individual shanks spaced 150 μm apart. Each shank consisted of a small groove that held an individual carbon fiber. Our results showed that the PEG coating allowed for the chronic implantation of carbon fiber arrays in five rats with unit activity detected at 31 days post-implant. The silicon support structures recorded single unit activity in three acute rat surgeries. In one of those surgeries a stacked device with three layers of silicon support structures and carbon fibers was built and shown to readily insert into the brain with unit activity on select sites. From these studies we have found that carbon fibers spaced at ∼150 μm readily insert into the brain. This greatly increases the recording density of chronic neural probes and paves the way for even higher density devices that have a minimal scarring response.

9 August 2013 in ACS Nano
Verified
Journal Article
Closed access
HZHuanan Zhang
Huanan Zhang
PPParas R. Patel
Paras R. Patel
ZXZhixing Xie
Zhixing Xie
SSScott D. Swanson
Scott D. Swanson
XWXueding Wang
Xueding Wang
NKNicholas A. Kotov
Nicholas A. Kotov

1 April 2020 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
EWElissa Joy Welle
Elissa Joy Welle
PPParas R Patel
Paras R Patel
JWJoshua E Woods
Joshua E Woods
APArtin Petrossians
Artin Petrossians
EVElena della Valle
Elena della Valle
CCCindy Chestek
Cindy Chestek
Objective. Carbon fiber electrodes may enable better long-term brain implants, minimizing the tissue response commonly seen with silicon-based electrodes. The small diameter fiber may enable high-channel count brain-machine interfaces capable of reproducing dexterous movements. Past carbon fiber electrodes exhibited both high fidelity single unit recordings and a healthy neuronal population immediately adjacent to the recording site. However, the recording yield of our carbon fiber arrays chronically implanted in the brain typically hovered around 30%, for previously unknown reasons. In this paper we investigated fabrication process modifications aimed at increasing recording yield and longevity. Approach. We tested a new cutting method using a 532nm laser against traditional scissor methods for the creation of the electrode recording site. We verified the efficacy of improved recording sites with impedance measurements and in vivo array recording yield. Additionally, we tested potentially longer-lasting coating alternatives to PEDOT:pTS, including PtIr and oxygen plasma etching. New coatings were evaluated with accelerated soak testing and acute recording. Main results. We found that the laser created a consistent, sustainable 257 ± 13.8 µ m 2 electrode with low 1 kHz impedance (19 ± 4 kΩ with PEDOT:pTS) and low fiber-to-fiber variability. The PEDOT:pTS coated laser cut fibers were found to have high recording yield in acute (97% > 100 µ V pp , N = 34 fibers) and chronic (84% > 100 µ V pp , day 7; 71% > 100 µ V pp , day 63, N = 45 fibers) settings. The laser cut recording sites were good platforms for the PtIr coating and oxygen plasma etching, slowing the increase in 1 kHz impedance compared to PEDOT:pTS in an accelerated soak test. Significance. We have found that laser cut carbon fibers have a high recording yield that can be maintained for over two months in vivo and that alternative coatings perform better than PEDOT:pTS in accelerated aging tests. This work provides evidence to support carbon fiber arrays as a viable approach to high-density, clinically-feasible brain-machine interfaces.

1 October 2020 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PPParas R Patel
Paras R Patel
PPPavlo Popov
Pavlo Popov
CCCiara M Caldwell
Ciara M Caldwell
EWElissa J Welle
Elissa J Welle
DEDaniel Egert
Daniel Egert
DCDawen Cai
Dawen Cai
Objective . Multimodal measurements at the neuronal level allow for detailed insight into local circuit function. However, most behavioral studies focus on one or two modalities and are generally limited by the available technology. Approach . Here, we show a combined approach of electrophysiology recordings, chemical sensing, and histological localization of the electrode tips within tissue. The key enabling technology is the underlying use of carbon fiber electrodes, which are small, electrically conductive, and sensitive to dopamine. The carbon fibers were functionalized by coating with Parylene C, a thin insulator with a high dielectric constant, coupled with selective re-exposure of the carbon surface using laser ablation. Main results. We demonstrate the use of this technology by implanting 16 channel arrays in the rat nucleus accumbens. Chronic electrophysiology and dopamine signals were detected 1 month post implant. Additionally, electrodes were left in the tissue, sliced in place during histology, and showed minimal tissue damage. Significance . Our results validate our new technology and methods, which will enable a more comprehensive circuit level understanding of the brain.