Artin Petrossians

Artin Petrossians

Auto-generated profile, based on publicly available information

Artin Petrossians

University of Southern California

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
EWElissa Joy Welle
Elissa Joy Welle
PPParas R Patel
Paras R Patel
JWJoshua E Woods
Joshua E Woods
APArtin Petrossians
Artin Petrossians
EVElena della Valle
Elena della Valle
CCCindy Chestek
Cindy Chestek
Objective. Carbon fiber electrodes may enable better long-term brain implants, minimizing the tissue response commonly seen with silicon-based electrodes. The small diameter fiber may enable high-channel count brain-machine interfaces capable of reproducing dexterous movements. Past carbon fiber electrodes exhibited both high fidelity single unit recordings and a healthy neuronal population immediately adjacent to the recording site. However, the recording yield of our carbon fiber arrays chronically implanted in the brain typically hovered around 30%, for previously unknown reasons. In this paper we investigated fabrication process modifications aimed at increasing recording yield and longevity. Approach. We tested a new cutting method using a 532nm laser against traditional scissor methods for the creation of the electrode recording site. We verified the efficacy of improved recording sites with impedance measurements and in vivo array recording yield. Additionally, we tested potentially longer-lasting coating alternatives to PEDOT:pTS, including PtIr and oxygen plasma etching. New coatings were evaluated with accelerated soak testing and acute recording. Main results. We found that the laser created a consistent, sustainable 257 ± 13.8 µ m 2 electrode with low 1 kHz impedance (19 ± 4 kΩ with PEDOT:pTS) and low fiber-to-fiber variability. The PEDOT:pTS coated laser cut fibers were found to have high recording yield in acute (97% > 100 µ V pp , N = 34 fibers) and chronic (84% > 100 µ V pp , day 7; 71% > 100 µ V pp , day 63, N = 45 fibers) settings. The laser cut recording sites were good platforms for the PtIr coating and oxygen plasma etching, slowing the increase in 1 kHz impedance compared to PEDOT:pTS in an accelerated soak test. Significance. We have found that laser cut carbon fibers have a high recording yield that can be maintained for over two months in vivo and that alternative coatings perform better than PEDOT:pTS in accelerated aging tests. This work provides evidence to support carbon fiber arrays as a viable approach to high-density, clinically-feasible brain-machine interfaces.

1 June 2020 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
ADAshley N Dalrymple
Ashley N Dalrymple
MHMario Huynh
Mario Huynh
BNBryony Nayagam
Bryony Nayagam
CLCurtis D Lee
Curtis D Lee
GWGreg R Weiland
Greg R Weiland
RSRobert K Shepherd
Robert K Shepherd
Objective. To evaluate the electrochemical properties, biological response, and surface characterization of an electrodeposited Platinum-Iridium (Pt-Ir) electrode coating on cochlear implants subjected to chronic stimulation in vivo. Approach . Electrochemical impedance spectroscopy (EIS), charge storage capacity (CSC), charge injection limit (CIL), and voltage transient (VT) impedance were measured bench-top before and after implant and in vivo . Coated Pt-Ir and uncoated Pt electrode arrays were implanted into cochlea of normal hearing rats and stimulated for ∼4 h d, 5 d week −1 for 5 weeks at levels within the normal clinical range. Neural function was monitored using electrically-evoked auditory brainstem responses. After explant, the electrode surfaces were assessed, and cochleae examined histologically. Main results . When measured on bench-top before and after stimulation, Pt-Ir coated electrodes had significantly lower VT impedance (p < 0.001) and significantly higher CSC (p < 0.001) and CIL (p < 0.001) compared to uncoated Pt electrodes. In vivo , the CSC and CIL of Pt-Ir were significantly higher than Pt throughout the implantation period ( p = 0.047 and p < 0.001, respectively); however, the VT impedance ( p = 0.3) was not. There was no difference in foreign body response between material cohorts, although cochleae implanted with coated electrodes contained small deposits of Pt-Ir. There was no evidence of increased neural loss or loss of neural function in either group. Surface examination revealed no Pt corrosion on any electrodes. Significance . Electrodeposited Pt-Ir electrodes demonstrated significant improvements in electrochemical performance on the bench-top and in vivo compared to uncoated Pt. Neural function and tissue response to Pt-Ir electrodes were not different from uncoated Pt, despite small deposits of Pt-Ir in the tissue capsule. Electrodeposited Pt-Ir coatings offer promise as an improved electrode coating for active neural prostheses.

22 May 2018 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
CLCurtis D. Lee
Curtis D. Lee
EHEric M. Hudak
Eric M. Hudak
JWJohn J. Whalen
John J. Whalen
APArtin Petrossians
Artin Petrossians
JWJames Weiland
James Weiland
A high surface area, Pt-Ir coating was electrodeposited onto the contacts of Advanced Bionics HiFocus 1j electrode arrays. The coating was imaged using optical and scanning electron microscopy (SEM) and the impedance was directly measured using clinically relevant voltage transients of biphasic pulses as short as 17 μs. The coating, which SEM showed to completely cover the underlying substrate, decreased the polarization impedance of 17 μs and 32 μs pulses by 91% and 93%, respectively.

1 February 2026 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
KSKee Scholten
Kee Scholten
Huijing XuHuijing Xu
Huijing Xu
ZLZhouxiao Lu
Zhouxiao Lu
WJWenxuan Jiang
Wenxuan Jiang
ZJZihan Jin
Zihan Jin
EMEllis Meng
Ellis Meng
Objective: Implantable polymer microelectrode arrays (pMEAs) offer stable integration with neural tissue but are not widely available. An academic resource model is explored as a means of standardizing and disseminating pMEAs. Methods: The resource is based on a multi-project wafer model, originally developed in the semiconductor industry, allowing the simultaneous microfabrication of pMEAs with arbitrary designs. This model leverages innovations in design, manufacturing, and packaging to produce custom penetrating, surface, and cuff-type form-factors in batch and at low cost. Device quality is verified through benchtop testing and chronic electrophysiological recording in rats. Results: To date, over 1000 pMEAs (more than 50 designs) were provided to 45 academic labs. Implanted penetrating arrays in the hippocampus achieved high quality, chronic recordings from freely moving rats. Surface arrays reliably recorded electroencephalogram signals from the cortex and evoked potentials from the somatosensory cortex in awake rats. Conclusion: Efficient production of custom pMEAs for research is possible through a unique resource model inspired by the semiconductor industry. Significance: Greater access to pMEAs enables researchers to conduct new experiments across different regions of the nervous system, accelerating discoveries.

6 November 2023 in bioRxiv
Verified
Preprint
Open access
PDF file
KSKee Scholten
Kee Scholten
HXHuijing Xu
Huijing Xu
ZLZhouxiao Lu
Zhouxiao Lu
WJWenxuan Jiang
Wenxuan Jiang
JOJessica Ortigoza-Diaz
Jessica Ortigoza-Diaz
EMEllis Meng
Ellis Meng
Large scale monitoring of neural activity at the single unit level can be achieved via electrophysiological recording using implanted microelectrodes. While neuroscience researchers have widely employed chronically implanted electrode-based interfaces for this purpose, a commonly encountered limitation is loss of highly resolved signals arising from immunological response over time. Next generation electrode-based interfaces improve longitudinal signal quality using the strategy of stabilizing the device-tissue interface with microelectrode arrays constructed from soft and flexible polymer materials. The limited availability of such polymer microelectrode arrays has restricted access to a small number of researchers able to build their own custom devices or who have developed specific collaborations with engineering researchers who can produce them. Here, a new technology resource model is introduced that seeks to widely increase access to polymer microelectrode arrays by the neuroscience research community. The Polymer Implantable Electrode (PIE) Foundry provides custom and standardized polymer microelectrode arrays as well as training and guidance on best-practices for implantation and chronic experiments.