Yuhao Li

Yuhao Li

Auto-generated profile, based on publicly available information

Yuhao Li

Laboratory of Clinical Nuclear Medicine Department of Nuclear Medicine West China Hospital, Sichuan University Chengdu 610041 China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2020 in Medical Image Analysis
Verified
Journal Article
Closed access
YPYong Pi
Yong Pi
ZZZhen Zhao
Zhen Zhao
YXYongzhao Xiang
Yongzhao Xiang
YLYuhao Li
Yuhao Li
HCHuawei Cai
Huawei Cai
ZYZhang Yi
Zhang Yi

31 May 2019 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
YLYuhao Li
Yuhao Li
LJLisha Jiang
Lisha Jiang
HWHaitao Wang
Haitao Wang
HCHuawei Cai
Huawei Cai
YXYongzhao Xiang
Yongzhao Xiang
LLLin Li
Lin Li
The aim was to estimate the effective doses associated with different types of scanning protocols and how much the diagnostic computed tomography (DCT) scan contributed to the total dose of the dual-modality positron emission tomography/computed tomography (PET/CT) examinations. The results showed that an average radiation dose of 8.19 ± 0.83 mSv and 13.44 ± 5.14 mSv for the PET and CT components, respectively, resulting in a total dose of 21.64 ± 5.20 mSv. Approximately 92.7% (980 of 1057) of the patients underwent additional DCT protocols. The DCT protocols contributed 42% of the overall effective radiation doses, which was larger than the percentage contributed by the PET component (38%) and LCT protocols (20%). Reducing the diagnostic area of the DCT scans that patients undergo and decreasing the use of chest-abdomen-pelvis (CAP), abdomen-pelvis (AP) and chest DCT protocols, especially the CAP protocol, will be helpful in decreasing the effective radiation doses of PET/CT scan.

19 May 2020 in Advanced Healthcare Materials
Verified
Journal Article
Closed access
PDF file
FPFuwen Pang
Fuwen Pang
YLYuhao Li
Yuhao Li
WZWenjie Zhang
Wenjie Zhang
CXChunchao Xia
Chunchao Xia
QHQing He
Qing He
LLLin Li
Lin Li

1 April 2020 in International Immunopharmacology
Verified
Journal Article
Closed access
TYTing Yang
Ting Yang
HWHao Wang
Hao Wang
YLYuhao Li
Yuhao Li
ZZZijian Zeng
Zijian Zeng
YSYongchun Shen
Yongchun Shen
FWFuqiang Wen
Fuqiang Wen

2 March 2023 in Advanced Functional Materials
Verified
Journal Article
Closed access
LDLiqun Dai
Liqun Dai
JLJie Liu
Jie Liu
XZXiaosheng Zhao
Xiaosheng Zhao
YLYuhao Li
Yuhao Li
SZSiming Zhou
Siming Zhou
ZQZhiyong Qian
Zhiyong Qian

5 July 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YLYuhao Li
Yuhao Li
HCHuawei Cai
Huawei Cai
GSGuohua Shen
Guohua Shen
FPFuwen Pang
Fuwen Pang
PDPing Dong
Ping Dong
LLLin Li
Lin Li
Iodine-131 (131I) is an essential and widely used radioisotope in thyroid diseases and animal experiments. Planar imaging has been considered the most popular method for 131I thyroid uptake radioactive activity quantification. The ROI defining section is essential and can affect the accuracy of quantitative results. However, a consistent method has not been proposed. In this study, a UC-ROI defining method based on ULWL setting and colour display grade was applied. Three steps were performed: image acquisition of five standard activity models and obtaining the exact value that the counts per radioactive activity contributes to the ROI; image acquisition of 20 rat thyroids and obtaining the counts of the ROI (thyroid); and calculating the rat thyroid radioactive activity and comparing these values with the true values. The accuracy of quantification activity of 131I in rat thyroid reached 2.62% ± 0.41%. The mean quantification within 5% could be achieved in 19 of 20 rat thyroids. No significant difference existed between calculated thyroid 131I activity and true values with a paired matched-test (t = −0.384, P = 0.706 > 0.05). The results indicated that with the UC-ROI defining method, more accurate thyroid uptake 131I radioactive activity quantification by SPECT planar imaging can be achieved in vivo rat study.