4 November 2024 in SoftwareX
31 July 2024 in IEEE Transactions on Instrumentation and Measurement
To address the challenges associated with pinpointing single and double switch open-circuit (OC) faults in conventional fault diagnosis strategies for T-type three-level inverters, a method for fault diagnosing based on energy feature extraction of intrinsic mode function (IMF) of voltage is proposed in this paper. Firstly, to mitigate modal aliasing and noise interference, the output voltage signal of the inverter is decomposed using the complete ensemble empirical mode decomposition (CEEMD) to extract IMF components. Subsequently, the short-term energy value of the selected IMF components is calculated by segmenting the decomposition results. By establishing a criterion for extracting fault features, the local variations in IMF short-term energy values at different fault locations are distinguished. Based on this criterion, a fault feature vector is constructed, enabling a diagnostic method for OC faults relying on the IMF components’ short-term energy values. Experimental results show that the fault diagnosis method proposed in this article can reliably achieve the diagnosis of single and double switch open-circuit faults in the T-type inverter. The proposed method does not require complex modeling, and has strong robustness and high accuracy compared to other types of diagnostic methods.