To address the challenges associated with pinpointing single and double switch open-circuit (OC) faults in conventional fault diagnosis strategies for T-type three-level inverters, a method for fault diagnosing based on energy feature extraction of intrinsic mode function (IMF) of voltage is proposed in this paper. Firstly, to mitigate modal aliasing and noise interference, the output voltage signal of the inverter is decomposed using the complete ensemble empirical mode decomposition (CEEMD) to extract IMF components. Subsequently, the short-term energy value of the selected IMF components is calculated by segmenting the decomposition results. By establishing a criterion for extracting fault features, the local variations in IMF short-term energy values at different fault locations are distinguished. Based on this criterion, a fault feature vector is constructed, enabling a diagnostic method for OC faults relying on the IMF components’ short-term energy values. Experimental results show that the fault diagnosis method proposed in this article can reliably achieve the diagnosis of single and double switch open-circuit faults in the T-type inverter. The proposed method does not require complex modeling, and has strong robustness and high accuracy compared to other types of diagnostic methods.
5 March 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Three-level T-type inverters are widely used due to their low losses and harmonic distortion. The increased number of switching devices raises failure probability, reducing inverter reliability. Hence, an accurate fault diagnosis method is essential for reliability enhancement. Based on the analysis of voltage vector trajectory under a single-phase single-switch fault in a three-level T-type inverter, voltage vector trajectory distortion characteristics of double-switch open-circuit faults are obtained through vector rotation and combined superposition. Furthermore, the relationship between the voltage vector trajectory distortion characteristics and the locations of open-circuit faults is deduced. Consequently, a diagnosis method is proposed based on the distortion characteristics of voltage vector trajectory. The angle of the distorted voltage vector trajectory is utilized to locate the fault phase, and the average voltage Park vector (AVPV) transformation is employed to obtain two diagnostic features: the normalized mean of phase voltage and the mean error of direct-axis voltage, which enables an accurate location of fault switches. An adaptive threshold is adopted. The method has low complexity and fast speed, with the diagnostic time ranging from 0.05 to 0.55 fundamental cycles. This method can realize the same-phase single-switch and double-switch fault diagnosis, reducing load sensitivity and misdiagnosis.