Massimiliano Della Pietra

Massimiliano Della Pietra

Auto-generated profile, based on publicly available information

Massimiliano Della Pietra

Laboratory for Development of Chemical Processes and Thermofluid Dynamics for Energy, Production, Conversion and Efficient Use of Energy Division, Energy Technologies Department, ENEA—Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Casaccia Research Centre, 00123 Rome, Italy

Research Focus & Metrics

Representative Publications

View All Publications
21 April 2021 in Frontiers in Energy Research
Verified
Journal Article
Open access
PDF file
Andrea Monforti FerrarioAndrea Monforti Ferrario
Andrea Monforti Ferrario
FSFrancesca Santoni
Francesca Santoni
MPMassimiliano Della Pietra
Massimiliano Della Pietra
Mosè RossiMosè Rossi
Mosè Rossi
NPNicola Piacente
Nicola Piacente
LSLuca Simonetti
Luca Simonetti
Technologies capable of efficiently exploiting unavoidable CO2 streams, have to be deeply investigated and deployed during the transition phase to achieve long-term climate neutrality targets. Among the technologies, Molten Carbonate Cells (MCC) Operating in Electrolysis Mode (MCEC) represents a promising facility to valorize CO2-rich waste streams, which are typically available in industrial plants, by their conversion into a high-value H2/CO syngas. These gaseous products can be reintegrated in a plant or reused in different applications. This study analyzes the integration of a system of the MCEC unit under different operating conditions in terms of composition, current density, and the utilization of fuels in a steam-reforming process of an Italian oil refinery via a mixed experimental-simulative approach. The aim of the current study is to assess the improvement in the overall product yield and further impacts of the MCEC unit on the plant efficiency. The results have shown that it is possible to obtain an electrochemical Specific Energy Consumption for the production of H2 of 3.24 kWh/NmH23 using the MCEC, whereby the possible integration of a 1-MWe module with a reformer of the proposed plant not only increases the hydrogen yield but also decreases the amount of fuel needed to assist the reforming reaction and separates a CO2 stream after additional purification via an oxy-fuel combustor, consequently determining lower greenhouse gases emissions.

18 May 2022 in Energies
Verified
Journal Article
Open access
PDF file
MAMohammad Alboghobeish
Mohammad Alboghobeish
Andrea Monforti FerrarioAndrea Monforti Ferrario
Andrea Monforti Ferrario
DPDavide Pumiglia
Davide Pumiglia
MPMassimiliano Della Pietra
Massimiliano Della Pietra
Stephen McPhailStephen McPhail
Stephen McPhail
Domenico BorelloDomenico Borello
Domenico Borello
Despite being commercially available, solid oxide fuel cell (SOFC) technology requires further study to understand its physicochemical processes for diagnostics, prognostics, and quality assurance purposes. Electrochemical impedance spectroscopy (EIS), a widely used characterization technique for SOFCs, is often accompanied by the distribution of relaxation times (DRT) as a method for deconvoluting the contribution of each physicochemical process from the aggregated impedance response spectra. While EIS yields valuable information for the operation of SOFCs, the quantitative analysis of the DRT and its shifts remains cumbersome. To address this issue, and to create a replicable benchmark for the assessment of DRT results, a custom tool was developed in MATLAB to numerically analyze the DRT spectra, identify the DRT peaks, and assess their deviation in terms of peak frequency and DRT amplitude from nominal operating conditions. The preliminary validation of the tool was carried out by applying the tool to an extensive experimental campaign on 23 SOFC button-sized samples from three production batches in which EIS measurements were performed in parametric operating conditions. It was concluded that the results of the automated analysis via the developed tool were in accordance with the qualitative analysis of previous studies. It is capable of providing adequate additional quantitative results in terms of DRT shifts for further analysis and provides the basis for better interoperability of DRT analyses between laboratories.

17 January 2025 in Journal of Power Sources
Verified
Journal Article
Closed access
SCSilvia Lo Conte
Silvia Lo Conte
SMSimone Mataloni
Simone Mataloni
MPMassimiliano Della Pietra
Massimiliano Della Pietra
LSLuca Simonetti
Luca Simonetti
YPYuri De Pra
Yuri De Pra
Maria Cristina  AnnesiniMaria Cristina Annesini
Maria Cristina Annesini

24 February 2026 in International Journal of Hydrogen Energy
Verified
Journal Article
Open access
FMFrancesco Marino
Francesco Marino
GLGabriele Loreti
Gabriele Loreti
MPMassimiliano Della Pietra
Massimiliano Della Pietra
Viviana CigolottiViviana Cigolotti
Viviana Cigolotti
GMGiulia Monteleone
Giulia Monteleone
EJElio Jannelli
Elio Jannelli

10 September 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
GCGabriella Di Cicco
Gabriella Di Cicco
DLDavide Lanni
Davide Lanni
Alessandra PernaAlessandra Perna
Alessandra Perna
AAAntonio Agresta
Antonio Agresta
MPMassimiliano Della Pietra
Massimiliano Della Pietra
Viviana CigolottiViviana Cigolotti
Viviana Cigolotti
Biogas-to-hydrogen pathways can support sustainable hydrogen refueling stations through on-site hydrogen production from renewable biogas. This study presents a techno-economic assessment of two on-grid biogas-to-hydrogen configurations based on steam and autothermal reforming, considering three station capacities of 200, 500, and 1000 kg H2/day. Technical models were integrated with an economic model to assess the effects of plant scale and economic conditions on overall performance. The technical results show that the overall specific energy consumption is approximately 63.7 kWh/kg H2 for autothermal reforming, compared with 80.0 kWh/kg H2 for steam reforming. The dispensed levelized cost of hydrogen (LCOH) decreases with increasing station capacity, from 10.61 to 8.06 €/kg H2 for steam reforming and from 11.28 to 8.08 €/kg H2 for autothermal reforming. At the assumed hydrogen selling price of 10.66 €/kg H2, economic performance improves with increasing station capacity. Under baseline conditions, steam reforming is more competitive at 200 and 500 kg H2/day, whereas the two configurations become nearly equivalent at 1000 kg H2/day. Sensitivity analyses show that BtH_SR is more competitive below biogas prices of approximately 0.058 and 0.042 €/kWh for the 500 and 1000 kg H2/day stations, respectively, while BtH_ATR is favored above these thresholds. Higher electricity prices favor BtH_SR, with the 1000 kg H2/day configurations becoming nearly equivalent at approximately 0.138 €/kWh. The nominal interest rate has the strongest effect on economic feasibility, with all investigated configurations becoming unfeasible above a value of 13.3%.

5 May 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
IXIrfan Xxx
Irfan Xxx
SFStefano Frangini
Stefano Frangini
MPMassimiliano Della Pietra
Massimiliano Della Pietra
CLCarina Lagergren
Carina Lagergren
JTJuan Pedro Pérez Trujillo
Juan Pedro Pérez Trujillo
Davide Astiaso GarciaDavide Astiaso Garcia
Davide Astiaso Garcia
Electrolyte matrix is an important component of Molten Carbonate Fuel Cells (MCFC) being responsible for both ionic conduction and gas sealing. The matrix should be full of electrolyte and have the ability to keep electrolyte carbonate. The main objective of this work is to optimize slurry formulation with the purpose of improving matrix porous structure and also of developing a more eco-friendly matrix fabrication process, which is usually made by Tape casting technique. Tape casting with optimized slurry formulation was employed to produce uniform thin ceramic green tapes with controlled- thickness and matrix porous structure. The optimized process parameters allowed us to produce a LiAlO2 ceramic matrix with porosity centered in the mesoporous range, and with high flexibility and mechanical integrity. The characteristics of the tapes were examined using Scanning Electron Microscopy (SEM) analysis, X-ray Power diffraction technique (XRD) and Brunauer Emmett Teller (BET) analysis. Finally two button cell tests were conducted with a 0.45 mm thick fabricated matrix. The testing results showed that cells had low internal resistance and significantly higher current density with respect to conventional cells. The results of the two cell experiments are highly reproducible reporting an internal resistance of 0.08-0.09 Ω cm2 and a current density in the range 0.38-0.5A/cm2 at 0.5V thus indicating the highly beneficial effect of a matrix mesoporous structure in improving MCFC cell performance beyond the state of the art technology.