Patrick F. Egan

Patrick F. Egan

Auto-generated profile, based on publicly available information

Patrick F. Egan

National Institute of Standards and Technology

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2023 in International Journal of Thermophysics
Verified
Journal Article
Closed access
PDF file
PEPatrick F. Egan
Patrick F. Egan
YYYuanchao Yang
Yuanchao Yang

1 April 2006 in Optics Letters
Verified
Journal Article
Open access
PDF file
PEPatrick Egan
Patrick Egan
MCMichael J. Connelly
Michael J. Connelly
FLFereydoun Lakestani
Fereydoun Lakestani
MWMaurice P. Whelan
Maurice P. Whelan
With analog scanning, time-domain low-coherence interferometry lacks precise depth information, and optical carrier generation demands a linear scanning speed. Full-field heterodyne low-coherence interferometry that uses a logarithmic complementary metal-oxide semiconductor camera, acousto-optic modulation, and digital depth stepping is reported, with which random regions of interest, lateral and axial, can be accessed. Furthermore, nanometer profilometry is possible through heterodyne phase retrieval of the interference signal. The approach demonstrates inexpensive yet high-precision functional machine vision offering true digital random access in three dimensions.

7 October 2024 in Metrologia
Verified
Journal Article
Closed access
PDF file
PEPatrick F Egan
Patrick F Egan
ESEric S Stanfield
Eric S Stanfield
JSJohn R Stoup
John R Stoup
CMChristopher W Meyer
Christopher W Meyer
Recent developments in diameter metrology at NIST have improved the dimensional characterization of piston–cylinder assemblies (PCAs) to unprecedented precision. For the newest generation of PCAs, the standard uncertainty in the measurement of the outer diameter is 12   nm , while uncertainty in the measurement of the inner diameter is 14   nm . With a high-accuracy dimensional dataset in hand, the task of determining the pressure generated by a specific PCA is reduced to converting the diameter (and straightness and roundness) to an effective area (and distortion coefficient). The details on how this was performed for the artifact PCA2062 are described. PCA2062 was dimensioned in 2017 and 2020; the area repeated within 0.2 × 10 − 6 ⋅ A 0 . The calculation produced estimates of fall rate and rotation decay that agreed with experimental observations within 12 %. The fall rate is proportional to the square of the gap width; therefore, the agreement between calculation and measurement validates the dimensional estimate of the gap width within ( 36 ± 42 )   nm , where the 42   nm standard uncertainty is governed by the present state of flow theory. The piston gage model is buttressed by three comparison tests against a laser barometer, which support a view that PCA2062 is linear and reproducible within 0.2   μ Pa   Pa − 1 . Finally, an estimate of uncertainty in the effective area of a dimensioned artifact is provided: as expected, the diameter measurement is the main culprit, but there are open questions regarding the flow model that preclude an accurate evaluation of the distortion coefficient. For the 530   kPa operating range of PCA2062, distortion is not a significant problem, but the effect would be dominant in assemblies operating at 1   MPa and above.

11 September 2024 in International Journal of Thermophysics
Verified
Journal Article
Open access
PDF file
PEPatrick F. Egan
Patrick F. Egan
A method is described to measure the thermal expansion coefficient of fused quartz glass. The measurement principle is to monitor the change in resonance frequency of a Fabry–Perot cavity as its temperature changes; the Fabry–Perot cavity is made from fused quartz glass. The standard uncertainty in the measurement was less than 0.6 $$(\textrm{nm}{\cdot } \textrm{m}^{-1}){\cdot }\textrm{K}^{-1}$$ ( nm · m - 1 ) · K - 1 , or 0.15 %. The limit on performance is arguably uncertainty in the reflection phase-shift temperature dependence, because neither thermooptic nor thermal expansion coefficients of thin-film coatings are reliably known. However, several other uncertainty contributors are at the same level of magnitude, and so any improvement in performance would entail significant effort. Furthermore, measurements of three different samples revealed that material inhomogeneity leads to differences in the effective thermal expansion coefficient of fused quartz; inhomogeneity in thermal expansion among samples is 24 times larger than the measurement uncertainty in a single sample.

17 June 2025 in Physical Review Applied
Verified
Journal Article
Closed access
YYYuanchao Yang
Yuanchao Yang
JSJack A. Stone
Jack A. Stone
PEPatrick F. Egan
Patrick F. Egan

3 August 2024 in International Journal of Thermophysics
Verified
Journal Article
Open access
PDF file
PEPatrick F. Egan
Patrick F. Egan
YYYuanchao Yang
Yuanchao Yang
Single-isotherm n(p, T90) results are reported for the gases Ar, N2, H2O, and D2O at vacuum wavelength $$\lambda = 1542.383(1)$$ λ = 1542.383 ( 1 ) nm. The argon and nitrogen isotherms were measured near 303 K; the water isotherms were measured near 373 K. Combined with the two previous articles of this series, the present results beget several insights via dispersion analyses. The argon result is highly consistent with static measurement plus ab initio calculation of dispersion polarizability. The nitrogen result is nominally consistent with one recent experiment and the dipole oscillator strength distributions, but the present work offers a refined estimate of the molar refractivity at optical wavelengths. For ordinary and heavy water, the dispersion trend is nominally consistent with existing liquid measurements. However, water’s absorption features in the near-infrared preclude a reliable comparison of the present result with literature.