1 April 2010 in Metrologia
7 October 2024 in Metrologia
Recent developments in diameter metrology at NIST have improved the dimensional characterization of piston–cylinder assemblies (PCAs) to unprecedented precision. For the newest generation of PCAs, the standard uncertainty in the measurement of the outer diameter is , while uncertainty in the measurement of the inner diameter is . With a high-accuracy dimensional dataset in hand, the task of determining the pressure generated by a specific PCA is reduced to converting the diameter (and straightness and roundness) to an effective area (and distortion coefficient). The details on how this was performed for the artifact PCA2062 are described. PCA2062 was dimensioned in 2017 and 2020; the area repeated within . The calculation produced estimates of fall rate and rotation decay that agreed with experimental observations within 12 %. The fall rate is proportional to the square of the gap width; therefore, the agreement between calculation and measurement validates the dimensional estimate of the gap width within , where the standard uncertainty is governed by the present state of flow theory. The piston gage model is buttressed by three comparison tests against a laser barometer, which support a view that PCA2062 is linear and reproducible within . Finally, an estimate of uncertainty in the effective area of a dimensioned artifact is provided: as expected, the diameter measurement is the main culprit, but there are open questions regarding the flow model that preclude an accurate evaluation of the distortion coefficient. For the operating range of PCA2062, distortion is not a significant problem, but the effect would be dominant in assemblies operating at and above.
20 November 2023 in Metrologia
The design, performance characteristics and validation of a next generation reference facility for carbon dioxide (CO2) in air standards based on manometry is presented. Novel attributes of the facility include automated operation, avoidance of significant pressure corrections for measurements on extracted CO2, fully characterized trapping efficiencies, and reduced measurement uncertainty. Improvements in system performance have been achieved using specific materials, notably Silconert®-treated stainless-steel, providing increased mechanical stability whilst minimizing carbon dioxide adsorption on surfaces, and avoiding use of elastomer O-rings, which would lead to losses of CO2. Full automation of the cryogenic extraction process of CO2 from air has been achieved, avoiding any manual intervention within the temperature stabilized section of the facility, and allowed full characterization and correction for trapping efficiencies and trace water measurement. The facility has been validated across the CO2 in air amount fraction range of (380–800) µmol mol−1 using standards with values traceable to the reference value of the CCQM−K120 (2018) comparison. It was demonstrated to operate with a standard measurement uncertainty of 0.09 µmol mol−1 at 400 µmol mol−1. The automation allows five measurement results per day to be produced with a typical standard deviation of the mean at or below 0.02 µmol mol−1. The facility will be used as a stable reference in the future BIPM.QM−K2 ongoing comparison, to compare consistency of amount fraction values in different CO2 in air standards. The CO2 amount fraction in two ensembles of nine BIPM standards covering the same range will also be measured with the facility to provide their SI-traceable values, and further monitored on a longer time scale. Each ensemble will constitute a CO2 in air scale to be compared with other available scales such as WMO.CO2.X2019 through the BIPM.QM−K5 comparison.
1 January 2025 in Metrologia
Main text: The report summarises the results of the CCT-K8 key comparison in the field of humidity. The main target of this comparison was to obtain the degree of equivalence (DoE) between realizations of local scales of dew point temperature of humid gas (air), in the range from 30 °C to 95 °C, among the participating national metrology institutes. The report gives details of the scheme, procedure and analysis of the comparison. The overall results display a very good agreement of the nine participating laboratories. The results show excellent agreement between the realized scales with no detected outliers. The performance of the travelling standards was excellent and can be attributed to the intensive preconditioning and selection of the platinum resistance thermometers, prior to their integration into the measuring head assembly, that led to insignificant drift. In the conclusion, some lessons learned are reported that could be beneficial for future key comparisons. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA). To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).