Geoff D. Moggridge

Geoff D. Moggridge

Auto-generated profile, based on publicly available information

Geoff D. Moggridge

Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, UK

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2006 in AIChE Journal
Verified
Journal Article
Open access
PDF file
RCR. Costa
R. Costa
GMG. D. Moggridge
G. D. Moggridge
AIAD NOVA IMS
AD NOVA IMS
Click on the article title to read more.

17 June 2020 in Biomaterials Science
Verified
Journal Article
Open access
PDF file
JSJoanna R. Stasiak
Joanna R. Stasiak
MSMarta Serrani
Marta Serrani
EBEugenia Biral
Eugenia Biral
JTJames V. Taylor
James V. Taylor
AZAzfar G. Zaman
Azfar G. Zaman
GMGeoff D. Moggridge
Geoff D. Moggridge
Clinically available prosthetic heart valves are life-saving, but imperfect: mechanical valves requiring anticoagulation therapy, whilst bioprosthetic valves have limited durability. Polymer valves offer the prospect of good durability without the need for anticoagulation. We report the design and development of a polymeric heart valve, its bench-testing at ISO standards, and preliminary extra-vivo and in vivo short-term feasibility. Prototypes were manufactured by injection moulding of styrenic block copolymers to achieve anisotropic mechanical properties. Design was by finite element stress–strain modelling, which has been reported previously, combined with feedback from bench and surgery-based testing using various combinations of materials, valve geometry and processing conditions. Bench testing was according to ISO 5840:2015 standards using an in vitro cardiovascular hydrodynamic testing system and an accelerated fatigue tester. Bench comparisons were made with a best-in-class bio-prosthesis. Preliminary clinical feasibility evaluations included extra-vivo and short-term (1–24 hours) in vivo testing in a sheep model. The optimised final prototype met the requirements of ISO standards with hydrodynamic performance equivalent to the best-in-class bioprosthesis. Bench durability of greater than 1.2 billion cycles (30 years equivalent) was achieved (still ongoing). Extra-vivo sequential testing (n = 8) allowed refinement of external diameter, 3D shape, a low profile, flexibility, suturability, and testing of compatibility to magnetic resonance imaging and clinical sterilisation. In vivo short-term (1–24 hours) feasibility (n = 3) confirmed good suturability, no mechanical failure, no trans-valvular regurgitation, competitive trans-valvular gradients, and good biocompatibility at histopathology. We have developed and tested at ISO standards a novel prosthetic heart valve featuring competitive bench-based hydrodynamics and durability, well beyond the ISO requirements and comparable to a best-in-class bioprosthesis. In vivo short-term feasibility testing confirmed preliminary safety, functionality and biocompatibility, supporting progression to a long-term efficacy trial.

26 June 2009 in Macromolecules
Verified
Journal Article
Closed access
JSJoanna Stasiak
Joanna Stasiak
ASAdam M. Squires
Adam M. Squires
VCValeria Castelletto
Valeria Castelletto
IHIan W. Hamley
Ian W. Hamley
GMGeoff D. Moggridge
Geoff D. Moggridge

24 March 2016 in Chemical Engineering Science
Verified
Journal Article
Open access
QZQ. Zhu
Q. Zhu
CDCarmine D'Agostino
Carmine D'Agostino
MAM. Ainte
M. Ainte
MMMichael David Mantle
Michael David Mantle
LGL.F. Gladden
L.F. Gladden
GMG.D. Moggridge
G.D. Moggridge
A new model for prediction of mutual diffusion coefficients is proposed over the whole composition range for binary liquid systems of one self-associating component and one non-polar component. The model is based on the Darken equation with the knowledge of intra-diffusion coefficients at infinite dilution of both species and viscosity data for the system, and takes into account the cluster diffusion approach with a scaling power on the thermodynamic correction factor. The model was validated to show good concurrence with the experimental mutual diffusion data. Following the analysis that the mutual diffusion coefficients at infinite dilution can be identified with the molecular intra-diffusion coefficient of the species (i.e., the intra-diffusion coefficient at infinite dilution in the absence of self-association), the proposed equation was extended to binary liquid systems without significant association. The accuracy of prediction for systems of cross associating species is expected to be limited. The model relies on the knowledge of the viscosity of the mixture over the whole composition range and may be used as a valid alternative to models based on measuring intra-diffusion coefficients as a function of composition. Indeed, such data are not always available or are more difficult to obtain whereas viscosity measurements can be readily available and more easily measured.

26 June 2014 in Soft Matter
Verified
Journal Article
Open access
PDF file
JSJoanna Stasiak
Joanna Stasiak
JBJacob Brubert
Jacob Brubert
MSMarta Serrani
Marta Serrani
SNSukumaran Nair
Sukumaran Nair
FGFrancesco De Gaetano
Francesco De Gaetano
GMGeoff D. Moggridge
Geoff D. Moggridge
A bi-directional, layered microstructure in cylinder forming block copolymers results from the local balance of shear and extensional flow during slow injection moulding.

9 April 2015 in Journal of Mechanics in Medicine and Biology
Verified
Journal Article
Open access
PDF file
FGFrancesco De Gaetano
Francesco De Gaetano
PBPaola Bagnoli
Paola Bagnoli
AZAdriano Zaffora
Adriano Zaffora
APAnna Pandolfi
Anna Pandolfi
MSMarta Serrani
Marta Serrani
MCMaria Laura Costantino
Maria Laura Costantino
The potential of polymeric heart valves (PHV) prostheses is to combine the hemodynamic performances of biological valves with the durability of mechanical valves. The aim of this work is to design and develop a new tri-leaflet prosthetic heart valve (HV) made from styrenic block copolymers. A computational finite element model was implemented to optimize the thickness of the leaflets, to improve PHV mechanical and hydrodynamic performances. Based on the model outcomes, 8 prototypes of the designed valve were produced and tested in vitro under continuous and pulsatile flow conditions, as prescribed by ISO 5840 Standard. A specially designed pulse duplicator allowed testing the PHVs at different flow rates and frequency conditions. All the PHVs met the requirements specified in ISO 5840 Standard in terms of both regurgitation and effective orifice area (EOA), demonstrating their potential as HV prostheses.