Hossein Iman-Eini

Hossein Iman-Eini

Auto-generated profile, based on publicly available information

Hossein Iman-Eini

School of Electrical and Computer Engineering College of Engineering University of Tehran Tehran Iran

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
ARAli Ramezani
Ali Ramezani
SFShahrokh Farhangi
Shahrokh Farhangi
HIHossein Iman-Eini
Hossein Iman-Eini
BFBabak Farhangi
Babak Farhangi
RRRamin Rahimi
Ramin Rahimi
GMGholam Reza Moradi
Gholam Reza Moradi
In this paper, an optimal design procedure for LCC-series compensation network is proposed for a stationary wireless Electric Vehicle (EV) charger. Main focus of this paper is to optimize the resonant network suitable for a wide range of operation from no-load to full power operation. The conventional methods only consider the full load condition to design the resonant network; in contrast, the proposed method employs a Time-Weighted Average Efficiency (TWAE) for different coupling conditions to achieve high efficiency over a wide load range including light-load and no-load operation. The resonant network is tuned to realize Zero Voltage Switching (ZVS) for the primary side inverter. Moreover, a Finite Element Analysis (FEA) is performed to calculate self and mutual inductances as well as core losses for magnetic couplers. In order to validate the feasibility of the proposed design, a 1 kW/85 kHz prototype with circular magnetic couplers is implemented. According to simulations and experiments, flat profiles for both efficiency and output voltage against output power variations are achieved. Experimental results demonstrate a 94.8% peak efficiency for the full-load operating.

11 December 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HBHamid Bahrami
Hamid Bahrami
SFShahrokh Farhangi
Shahrokh Farhangi
HIHossein Iman-Eini
Hossein Iman-Eini
EAEhsan Adib
Ehsan Adib
This paper presents a new interleaved coupled-inductor nonisolated bidirectional dc-dc converter that provides high voltage gain ratio (VGR), low ripple current at the low-voltage side (LVS), and soft switching. The high VGR is obtained by connecting in series the outputs of an interleaved bidirectional buck-boost converter and a dual-active half-bridge converter, using the turns ratio of a coupled inductor. Since the voltage of the high-voltage side is shared between the converters outputs, the voltage stress across the active switches decrease. The active switches turn ON under zero-voltage switching condition in both directions. Moreover, the low current ripple at the LVS is achieved due to the applied interleaved technique. By employing the phase-shift angle modulation, the output voltage is regulated. The proposed converter is analyzed in details and a 900-W experimental prototype with 48-V input voltage and 400-V output voltage under 100-kHz switching frequency is implemented to verify the theoretical results.

1 April 2013 in IET Power Electronics
Verified
Journal Article
Open access
PDF file
MAMohsen Aleenejad
Mohsen Aleenejad
HIHossein Iman‐Eini
Hossein Iman‐Eini
SFShahrokh Farhangi
Shahrokh Farhangi
In this study, fault‐tolerant operation of multilevel cascaded H‐bridge (CHB) inverters is presented and a novel switching strategy based on space vector modulation is proposed. A faulty power switch in high power converters can lead to expensive downtime, loss of productivity and increased costs. Various power switch faults and their influence on space vector diagram of CHB inverters are investigated. In the event of a fault, the output voltage of inverter is reduced and redundant switching states are used to generate balanced line‐to‐line voltages. By adding some devices to the basic structure, CHB inverter will operate with maximum achievable output voltage. Simulation and experimental results are shown for a five‐level CHB inverter to validate the proposed modulation technique.

9 July 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
SASara Allahabadi
Sara Allahabadi
HIHossein Iman-Eini
Hossein Iman-Eini
SFShahrokh Farhangi
Shahrokh Farhangi
In partially shaded photovoltaic (PV) arrays, the power-voltage curve displays multiple maxima, one of which is the global maximum power point (GMPP). One of the major concerns related to PV systems is to locate and track the GMPP in all circumstances to boost efficiency. Combining conventional hill climbing (HC) algorithm and artificial neural networks (ANNs), a new two-stage GMPP tracking method is introduced in this article that aims to be fast and accurate. Moreover, it does not require irradiance or temperature sensors. In the first stage, the current-voltage (I-V) curve is sampled at specific points determined based on the array I-V curve analysis with the objective to be the minimum samples possible that can reflect the changes of irradiance and temperature. Then a simple feedforward ANN is employed to estimate the neighborhood of the GMPP using these samples. In the second stage, the HC algorithm is adopted to ensure the GMPP is tracked precisely. The proposed method is validated by simulations in MATLAB/Simulink environment and experimental tests under uniform irradiance condition, partial shading conditions, and a wide range of temperatures.

15 January 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YNYousef Neyshabouri
Yousef Neyshabouri
HIHossein Iman-Eini
Hossein Iman-Eini
This paper introduces a new fault-tolerant strategy for a cascaded H-bridge (CHB)-based static synchronous compensator (STATCOM) with a single failure in power switches. A modified selective harmonic elimination pulse width modulation technique is proposed for postfault operation which generates the maximum possible balanced line-to-line voltages at the ac side of the converter. The dc-link voltages of H-bridge cells are used as another degree of freedom; and by an efficient amount of increase at the dc-link voltages, the rated capacity of STATCOM is restored without any extra component. Furthermore, by applying an effective voltage balancing scheme, voltages of dc-side capacitors are kept balanced in postfault operation. A three-phase seven-level CHB-based STATCOM is simulated in PSCAD/EMTDC environment to verify the feasibility and performance of the proposed method and also experimental results are provided based on a three-phase five-level scaled down laboratory prototype which validates the effectiveness of the proposed strategy.

9 March 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
RSRahman Sajadi
Rahman Sajadi
HIHossein Iman-Eini
Hossein Iman-Eini
MBMohammad Kazem Bakhshizadeh
Mohammad Kazem Bakhshizadeh
YNYousef Neyshabouri
Yousef Neyshabouri
SFShahrokh Farhangi
Shahrokh Farhangi
In this paper, the selective harmonic elimination (SHE) technique is introduced for a cascaded H-bridge-based static VAR compensator (CHB-STATCOM) with unequal capacitive dc-link voltages. The asymmetric topology allows increasing the number of voltage levels while keeping the converter losses low. Moreover, reactive power control is realized by using the decoupled current control, and the voltage of individual capacitors is controlled by the help of SHE modulation. Mathematical equations are derived for synthesizing the multilevel ac waveform and regulation of dc-link voltages for a CHB inverter with an arbitrary number of H-bridge cells. Then, to verify the theoretical claims, simulation and experimental results are provided for a three-phase CHB inverter with two H-bridge cells in each phase.