1 August 2019 in Physics in Medicine & Biology
Recently, multileaf collimator (MLC)-tracking has been technically and clinically demonstrated showing promising improvements of radiotherapy of mobile sites. Furthermore, magnetic resonance imaging (MRI)-guided treatments have shown to provide superior targetting performance due to on-line soft-tissue imaging. Hitherto, the combination of MLC-tracking and MRI has not been investigated using clinically released hardware. In this note we aim to describe the technical feasibilty of such a combination on a clinically operating MRI-linac. The MLC-tracking system is characterized by quantifying the latencies and geometric errors produced by the system. In order to reach optimization recommendations, the tracking system was first characterized using a quasi-ideal position sensor, isolating the performance of the MLC only. Subsequently, the analysis was repeated using real-time MRI as the positioning source for the MLC. For the isolated MLC, we found latencies of 20.67 ms and minimal overshooting behaviour. The latencies for MRI-guidance were 347.45 ms at 4 Hz imaging and 204 ms at 8 Hz. We showed that MLC-tracking on the Elekta Unity using integrated MRI is technically supported and feasible. The isolated analysis of the MLC demonstrated the negligible contribution of the MLC in MRI-guided tracking. The latency and geometric errors caused by the sampling properties of MRI exceed the MLC-related errors by several factors. Most gain for real-time MRI-based adaptive radiotherapy can therefore be realized by optimizing and accelerating the MRI acquisition process.
1 June 2019 in Physics in Medicine & Biology
This work aimed to quantify any principal magnetic field ( B 0 ) inhomogeneity and changes in MR image geometric distortion with continuous linac gantry rotation on an Elekta Unity MR-linac. This situation occurs for around a second between treatment beams during current image guided radiotherapy treatment and would occur frequently in foreseeable real-time adaptive radiotherapy treatment. Pixel by pixel maps of B 0 inhomogeneity were obtained via repeated high temporal resolution pulse sequences with the linac gantry static at 36 gantry angles spaced ten degrees apart, and in continuous rotation at both 1 and 2 rpm. Individual B 0 maps were subtracted from average maps across all data and the residual peak to peak inhomogeneity was calculated for each. The bulk geometric shift and change in physical extent of a 10 cm diameter spherical flood phantom during continuous linac gantry rotation at 1 and 2 rpm was compared to the static gantry case for two pulse sequences: the real-time clinical monitoring bFFE sequence and a non-clinical EPI sequence, chosen for its susceptibility to geometric distortion. The peak to peak inhomogeneity in the deviation-from-average ppm maps, plotted against gantry angle with the gantry in continuous rotation at 1 and 2 rpm were negligibly different from equivalent data obtained with the gantry static. The real-time clinical monitoring pulse sequence was shown to give negligible geometric distortion during continuous gantry motion, whilst a non-clinical EPI sequence showed bulk shifts of the order of one pixel and gantry angle dependent changes in extent, demonstrating the sensitivity of the chosen method. MR imaging on the Elekta Unity MR-Linac with the gantry in continuous motion is negligibly different from the static gantry case with current clinical pulse sequences. Real-time tracking and treatment plan adaptation using MR images obtained with the linac gantry in motion is possible.
1 January 2022 in at - Automatisierungstechnik
Finding and implementing a suitable machine learning (ML) solution to a task at hand has several facets. The technical side of ML has widely been discussed in detail, see, e. g., (Heizmann, M., A. Braun, M. Hüttel, C. Klüver, E. Marquardt, M. Overdick and M. Ulrich. 2020. Artificial Intelligence with Neural Networks in Optical Measurement and Inspection Systems. at – Automatisierungstechnik 68(6): 477–487). This contribution focusses on the industrial implementation issues of ML projects, particularly for machine vision (MV) tasks. Especially in small and medium-sized enterprises (SMEs), resources cannot be activated at will in order to use a new technology like ML. We take this into account by, on the one hand, helping to realistically evaluate the opportunities and challenges involved in implementing ML projects for a given task. On the other hand, we consider not only technical aspects, but also organizational, social and customer-related ones. It is discussed which know-how a company itself has to bring into an ML project and which tasks can also be performed by service providers. Here, it becomes clear that ML techniques can be used at different levels of detail. The question of “make or buy” is therefore also an entrepreneurial one when introducing ML into one’s own products and processes, and must be answered with a view to one’s own possibilities and structures.
1 September 2019 in Physics in Medicine & Biology
With the recent advent of hybrid MRI-guided radiotherapy systems, continuous intra-fraction MR imaging for motion monitoring has become feasible. The ability to perform real-time custom image reconstructions is however often lacking. In this work we present a low-latency streaming solution, ReconSocket , which provides a real-time stream of k-space data from the magnetic resonance imaging (MRI) to custom reconstruction servers. We determined the performance of the data streaming by measuring the streaming latency (i.e. non-zero time delay due to data transfer and processing) and jitter (i.e. deviations from periodicity) using an ultra-fast 1D MRI acquisition of a moving phantom. Simultaneously, its position was recorded with near-zero time delay. The feasibility of low-latency custom reconstructions was tested by measuring the imaging latency (i.e. time delay between physical change and appearance of that change on the image) for several non-Cartesian 2D and 3D acquisitions using an in-house implemented reconstruction server. The measured streaming latency of the ReconSocket interface was ms. 98% of the incoming data packets arrived within a jitter range of 367 s. This shows that the ReconSocket interface can provide reliable real-time access to MRI data, acquired during the course of a MRI-guided radiotherapy fraction. The total imaging latency was measured to be 221 ms (2D) and 3889 ms (3D) for exemplary acquisitions, using the custom image reconstruction server. These imaging latencies are approximately equal to half of the temporal footprint ( T
acq
/2) of the respective 2D and 3D golden-angle radial sequences. For radial sequences, it was previously showed that T
acq
/2 is the expected contribution of only the data acquisition to the total imaging latency. Indeed, the contribution of the non-Cartesian reconstruction to the total imaging latency was minor (<10%): 21 ms for 2D, 300 ms for 3D, indicating that the acquisition, i.e. the physical encoding of the image itself is the major contributor to the total imaging latency.