Department of Radiotherapy Related Research, The Christie NHS Foundation Trust, Manchester, United Kingdom. Author to whom any correspondence should be addressed

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
SJSteven James Jackson
Steven James Jackson
MGMarkus Glitzner
Markus Glitzner
RTRob H N Tijssen
Rob H N Tijssen
BRBas W Raaymakers
Bas W Raaymakers
This work aimed to quantify any principal magnetic field ( B 0 ) inhomogeneity and changes in MR image geometric distortion with continuous linac gantry rotation on an Elekta Unity MR-linac. This situation occurs for around a second between treatment beams during current image guided radiotherapy treatment and would occur frequently in foreseeable real-time adaptive radiotherapy treatment. Pixel by pixel maps of B 0 inhomogeneity were obtained via repeated high temporal resolution pulse sequences with the linac gantry static at 36 gantry angles spaced ten degrees apart, and in continuous rotation at both 1 and 2 rpm. Individual B 0 maps were subtracted from average maps across all data and the residual peak to peak inhomogeneity was calculated for each. The bulk geometric shift and change in physical extent of a 10 cm diameter spherical flood phantom during continuous linac gantry rotation at 1 and 2 rpm was compared to the static gantry case for two pulse sequences: the real-time clinical monitoring bFFE sequence and a non-clinical EPI sequence, chosen for its susceptibility to geometric distortion. The peak to peak inhomogeneity in the deviation-from-average ppm maps, plotted against gantry angle with the gantry in continuous rotation at 1 and 2 rpm were negligibly different from equivalent data obtained with the gantry static. The real-time clinical monitoring pulse sequence was shown to give negligible geometric distortion during continuous gantry motion, whilst a non-clinical EPI sequence showed bulk shifts of the order of one pixel and gantry angle dependent changes in extent, demonstrating the sensitivity of the chosen method. MR imaging on the Elekta Unity MR-Linac with the gantry in continuous motion is negligibly different from the static gantry case with current clinical pulse sequences. Real-time tracking and treatment plan adaptation using MR images obtained with the linac gantry in motion is possible.

14 February 2019 in Ultrasound
Verified
Journal Article
Closed access
PDF file
SJSteven J Jackson
Steven J Jackson
SRStephen Russell
Stephen Russell
A precise, reproducible method for measuring ultrasound probe slice thickness has been developed for linear array ultrasound probes. The method used a custom built jig to draw the probe along the surface of a Gammex 403 phantom, with the image plane parallel to the filaments within the phantom. Still images at 0.5 mm intervals are saved for post-processing using in-house software. Slice thickness measurements with a precision of 0.1 mm are obtained. The method was shown to give reproducible estimates of probe slice thickness at several depths to within 0.4 mm during repeat tests. The method was able to provide information about the slice thickness of different sections of the probe face. It is expected that the method can quantify changes in probe performance due to lens wear or replacement over time that may elude both in-plane and in-air reverberation-based tests. A total of 18 linear probes were tested across eight centres, including six specialist vascular ultrasound centres.