Jie Deng

Jie Deng

Auto-generated profile, based on publicly available information

Jie Deng

Department of Radiation Oncology, The University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, Texas, 75390-9303, UNITED STATES

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2022 in Physica Medica
Verified
Journal Article
Closed access
YWYunan Wu
Yunan Wu
JLJunchi Liu
Junchi Liu
GWGregory M. White
Gregory M. White
JDJie Deng
Jie Deng

31 August 2023 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
FVFarzan Vahedifard
Farzan Vahedifard
Xuchu LiuXuchu Liu
Xuchu Liu
JAJubril O. Adepoju
Jubril O. Adepoju
SZShiqiao Zhao
Shiqiao Zhao
HAHua Asher Ai
Hua Asher Ai
JDJie Deng
Jie Deng
BACKGROUND AND PURPOSE: An MRI of the fetus can enhance the identification of perinatal developmental disorders, which improves the accuracy of ultrasound. Manual MRI measurements require training, time, and intra-variability concerns. Pediatric neuroradiologists are also in short supply. Our purpose was developing a deep learning model and pipeline for automatically identifying anatomic landmarks on the pons and vermis in fetal brain MR imaging and suggesting suitable images for measuring the pons and vermis. MATERIALS AND METHODS: We retrospectively used 55 pregnant patients who underwent fetal brain MR imaging with a HASTE protocol. Pediatric neuroradiologists selected them for landmark annotation on sagittal single-shot T2-weighted images, and the clinically reliable method was used as the criterion standard for the measurement of the pons and vermis. A U-Net-based deep learning model was developed to automatically identify fetal brain anatomic landmarks, including the 2 anterior-posterior landmarks of the pons and 2 anterior-posterior and 2 superior-inferior landmarks of the vermis. Four-fold cross-validation was performed to test the accuracy of the model using randomly divided and sorted gestational age–divided data sets. A confidence score of model prediction was generated for each testing case. RESULTS: Overall, 85% of the testing results showed a ≥90% confidence, with a mean error of <2.22 mm, providing overall better estimation results with fewer errors and higher confidence scores. The anterior and posterior pons and anterior vermis showed better estimation (which means fewer errors in landmark localization) and accuracy and a higher confidence level than other landmarks. We also developed a graphic user interface for clinical use. CONCLUSIONS: This deep learning–facilitated pipeline practically shortens the time spent on selecting good-quality fetal brain images and performing anatomic measurements for radiologists.

8 August 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
HSHua-Chieh Shao
Hua-Chieh Shao
XQXiaoxue Qian
Xiaoxue Qian
GXGuoping Xu
Guoping Xu
CWCan Wu
Can Wu
RORicardo Otazo
Ricardo Otazo
YZYou Zhang
You Zhang
Objective: Based on a 3D pre-treatment magnetic resonance (MR) scan, we developed DREME-MR to jointly reconstruct the reference patient anatomy and solve a data-driven, patient-specific cardiorespiratory motion model. Via a motion encoder simultaneously learned during the reconstruction, DREME-MR further enables real-time volumetric MR imaging and cardiorespiratory motion tracking with minimal intra-treatment k-space data. Approach: DREME-MR integrates dynamic MRI reconstruction and real-time MR imaging into a unified, dual-task learning framework. From a 3D radial-spoke-based pre-treatment MR scan, DREME-MR uses spatiotemporal implicit-neural-representation (INR) to reconstruct pre-treatment dynamic volumetric MR images (learning task 1). The INR-based reconstruction takes a joint image reconstruction and deformable registration approach, yielding a reference anatomy and a corresponding cardiorespiratory motion model. The motion model adopts a low-rank, multi-resolution representation to approximate motion fields as products of motion coefficients and motion basis components (MBCs). Via a progressive, frequency-guided strategy, DREME-MR decouples cardiac MBCs from respiratory MBCs to resolve the two distinct motion modes. Simultaneously with the pre-treatment dynamic MRI reconstruction, DREME-MR also trains a multilayer perceptron (MLP)-based motion encoder to infer cardiorespiratory motion coefficients directly from the raw k-space data (learning task 2), allowing real-time, intra-treatment volumetric MR imaging and motion tracking with minimal k-space data (20-30 spokes) acquired after the pre-treatment MRI scan. Main results: Evaluated using data from a digital phantom (XCAT) and a human scan, DREME-MR solves real-time 3D cardiorespiratory motion with a latency of < 165 ms (= 150-ms data acquisition + 15-ms inference time), fulfilling the temporal constraint of real-time imaging. The XCAT study achieves mean(±S.D.) center-of-mass tracking errors of 0.73±0.38mm for a lung tumor and 1.69±1.12mm for the left ventricle. The human study shows good motion correlations (liver: 0.96; left ventricle: 0.65) between DREME-MR-solved motion and extracted surrogate signals. Significance: DREME-MR allows real-time 3D MRI and cardiorespiratory motion tracking with low latency, advancing intra-treatment MR-guided adaptive radiotherapy, including real-time multileaf collimator (MLC) tracking.

21 August 2025 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
JDJie Deng
Jie Deng
XLXiao Liang
Xiao Liang
VIViktor Iakovenko
Viktor Iakovenko
BMBoyu Meng
Boyu Meng
JWJunjie Wu
Junjie Wu
AGAndrew Godley
Andrew Godley
Background: In external beam radiation therapy (EBRT) for prostate cancer, both MRI and CT are typically used—CT provides electron density for dose calculation and visualization of bony anatomy and fiducial markers, while MRI offers superior soft tissue contrast. With recent advances in deep learning, synthetic CT (sCT) images can now be generated from MRI, potentially eliminating the need for separate CT scans. Purpose: To clinically implement an MRI‐only planning (MROP) workflow for both X‐ray and MRI‐guided systems. Methods: MROP implementation involved optimizing MRI simulation protocols, developing a deep learning‐based sCT generation method, and automating fiducial marker detection. A multichannel CycleGAN model was trained using T1‐weighted Dixon images to generate sCT. For SBRT cases, the immobilization device was auto‐inserted into sCT images. Fiducial markers were detected using a quantitative susceptibility mapping (QSM) method. Validation included retrospective comparison of Hounsfield units and dosimetric plans to those based on planning CT for 11 patients, followed by prospective evaluation of ten patients. Results: The MRI protocol included T2‐weighted 3D imaging for contouring, T1‐weighted Dixon for sCT, and T2*‐weighted GRE for fiducial detection. The MROP workflow was prospectively applied in 10 patients (three SBRT, seven conventional). Dosimetric comparisons showed <1% difference between MROP and CT‐based plans across all PTVs. The QSM‐based fiducial detection achieved a 95.5% success rate (63/66 markers) and reduced detection time from ∼10 to 2 min per patient. All MROP components were integrated into the treatment planning system via scripting. Implementation reduced simulation scheduling time by 7.1 days. Conclusion: We successfully implemented an MROP workflow for prostate cancer EBRT, eliminating the need for CT, reducing radiation exposure, and improving clinical efficiency. Over 500 patients have been treated to date using this approach on both C‐arm and MR‐guided systems.

9 January 2025 in Medical Physics
Verified
Journal Article
Open access
YDYan Dai
Yan Dai
XJXun Jia
Xun Jia
JLJiaen Liu
Jiaen Liu
YLYen‐Peng Liao
Yen‐Peng Liao
JDJie Deng
Jie Deng
Background: Diffusion‐weighted (DW) turbo‐spin‐echo (TSE) imaging offers improved geometric fidelity compared to single‐shot echo‐planar‐imaging (EPI). However, it suffers from low signal‐to‐noise ratio (SNR) and prolonged acquisition times, thereby restricting its applications in diagnosis and MRI‐guided radiotherapy (MRgRT). Purpose: To develop a joint k‐b space reconstruction algorithm for concurrent reconstruction of DW‐TSE images and the apparent diffusion coefficient (ADC) map with enhanced image quality and more accurate quantitative measurements. Methods: The joint k‐b reconstruction model was formulated as an optimization problem subject to a self‐consistency condition comprising the exponential decay relationship between DW images and the ADC map. The objective function included a data fidelity term confirming an agreement between the reconstructed images and measured k‐space data, incorporating the mono‐exponential decay relationship between DW images and ADC map as a constraint, along with spatial regularization terms on both amplitude and phase images. The optimization problem was solved using the alternating‐direction method of multipliers (ADMM). We evaluated the performance of the joint reconstruction (JR) algorithm for DW‐TSE in a phantom study and patient studies on five brain and head/neck cancer patients. Image distortion, accuracy, and repeatability of ADC measurements were assessed and compared with those from conventional Fourier‐transformed (FFT)‐based reconstruction and magnitude‐based ADC fitting methods, as well as with the clinically used DW‐EPI technique. Results: The proposed joint k‐b reconstruction method demonstrated improved SNR and enhanced accuracy of ADC measurements in DW‐TSE compared to the conventional method. Additionally, JR‐DW‐TSE with fewer averages at high b‐values provided better image quality than the conventional FFT‐reconstructed DW‐TSE with full averages. Conclusion: The proposed joint k‐b reconstruction method for DW‐TSE has the potential to deliver distortion‐robust diffusion‐weighted MRI (DWI) for clinical applications, which is particularly crucial for MRgRT.

7 November 2025 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
YDYan Dai
Yan Dai
XJXun Jia
Xun Jia
YLYen-Peng Liao
Yen-Peng Liao
DJDeng Jie
Deng Jie