Andrew Godley

Dr. Andrew Godley

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2024 in Cancers
Verified
Journal Article
Open access
PDF file
HZHaozhao Zhang
Haozhao Zhang
MDMichael Dohopolski
Michael Dohopolski
SSStrahinja Stojadinovic
Strahinja Stojadinovic
LSLuiza Giuliani Schmitt
Luiza Giuliani Schmitt
SASoummitra Anand
Soummitra Anand
HPHao Peng
Hao Peng
Objectives: This retrospective study aims to develop a multiomics approach that integrates radiomics, dosiomics, and delta features to predict treatment responses in brain metastasis (BM) patients undergoing PULSAR. Methods: A retrospective study encompassing 39 BM patients with 69 lesions treated with PULSAR was undertaken. Radiomics, dosiomics, and delta features were extracted from both pre-treatment and intra-treatment MRI scans alongside dose distributions. Six individual models, alongside an ensemble feature selection (EFS) model, were evaluated. The classification task focused on distinguishing between two lesion groups based on whether they exhibited a volume reduction of more than 20% at follow-up. Performance metrics, including sensitivity, specificity, accuracy, precision, F1 score, and the area under the receiver operating characteristic (ROC) curve (AUC), were assessed. Results: The EFS model integrated the features from pre-treatment radiomics, pre-treatment dosiomics, intra-treatment radiomics, and delta radiomics. It outperformed six individual models, achieving an AUC of 0.979, accuracy of 0.917, and F1 score of 0.821. Among the top nine features of the EFS model, six features came from post-wavelet transformation and three from original images. Conclusions: The study demonstrated the feasibility of employing a data-driven multiomics approach to predict treatment outcomes in BM patients receiving PULSAR treatment. Integrating multiomics with intra-treatment decision support in PULSAR shows promise for optimizing patient management and reducing the risks of under- or over-treatment.

10 April 2023 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
TZTingliang Zhuang
Tingliang Zhuang
GGGrant Gibbard
Grant Gibbard
XDXinhui Duan
Xinhui Duan
JTJun Tan
Jun Tan
YPYang Park
Yang Park
BCBin Cai
Bin Cai
A recently developed biology-guided radiotherapy platform, equipped with positron emission tomography (PET) and computed tomography (CT), provides both anatomical and functional image guidance for radiotherapy. This study aimed to characterize performance of the kilovoltage CT (kVCT) system on this platform using standard quality metrics measured on phantom and patient images, using CT simulator images as reference. Image quality metrics, including spatial resolution/modular transfer function (MTF), slice sensitivity profile (SSP), noise performance and image uniformity, contrast-noise ratio (CNR) and low-contrast resolution, geometric accuracy, and CT number (HU) accuracy, were evaluated on phantom images. Patient images were evaluated mainly qualitatively. On phantom images the MTF10% is about 0.68 lp/mm for kVCT in PET/CT Linac. The SSP agreed with nominal slice thickness within 0.7 mm. The diameter of the smallest visible target (1% contrast) is about 5 mm using medium dose mode. The image uniformity is within 2.0 HU. The geometric accuracy tests passed within 0.5 mm. Relative to CT simulator images, the noise is generally higher and the CNR is lower in PET/CT Linac kVCT images. The CT number accuracy is comparable between the two systems with maximum deviation from the phantom manufacturer range within 25 HU. On patient images, higher spatial resolution and image noise are observed on PET/CT Linac kVCT images. Major image quality metrics of the PET/CT Linac kVCT were within vendor-recommended tolerances. Better spatial resolution but higher noise and better/comparable low contrast visibility were observed as compared to a CT simulator when images were acquired with clinical protocols.

25 July 2025 in Cancers
Verified
Journal Article
Open access
PDF file
BCBin Cai
Bin Cai
TBThomas I. Banks
Thomas I. Banks
CSChenyang Shen
Chenyang Shen
RPRameshwar Prasad
Rameshwar Prasad
GBGirish Bal
Girish Bal
SBShahed N. Badiyan
Shahed N. Badiyan
Background/Objectives: This study aims to present a structured clinical workflow for offline adaptive Biology-guided Radiotherapy (BgRT) using the RefleXion X1 PET-linac system, addressing challenges introduced by inter-treatment anatomical and biological changes. Methods: We propose a decision tree offline adaptation framework based on real-time assessments of Activity Concentration (AC), Normalized Target Signal (NTS), and bounded dose-volume histogram (bDVH%) metrics. Three offline strategies were developed: (1) preemptive adaptation for minor changes, (2) partial re-simulation for moderate changes, and (3) full re-simulation for major anatomical or metabolic alterations. Two clinical cases demonstrating strategies 1 and 2 are presented. Results: The preemptive adaptation strategy was applied in a case with early tumor shrinkage, maintaining delivery parameters within acceptable limits while updating contours and dose distribution. In the partial re-Simulation case, significant changes in PET signal necessitated a same-day PET functional modeling session and plan re-optimization, effectively restoring safe deliverability. Both cases showed reduced target volumes and improved OAR sparing without additional patient visits or tracer injections. Conclusions: Offline adaptive workflows for BgRT provide practical solutions to address inter-fractional changes in tumor structure and function. These strategies can help maintain the safety and accuracy of BgRT delivery and support clinical adoption of PET-guided radiotherapy, paving the way for future online adaptive capabilities.

17 August 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JHJing Hao
Jing Hao
AGAndrew Godley
Andrew Godley
JSJocelyn D Shoemake
Jocelyn D Shoemake
ZHZheyi Han
Zheyi Han
AMAnthony Magnelli
Anthony Magnelli
JYJennifer Yu
Jennifer Yu
Radiation therapy is an integral part of treatment for patients with glioblastoma. New technological advances in linear accelerators have made extra-high dose rate irradiation possible. This shortens patient treatment time significantly compared to standard dose rate irradiation, but the biologic effects of extra high dose rate irradiation are poorly understood. Glioma stem-like cells (GSCs) are resistant to standard radiation and contribute to tumor progression. Here, we assess the therapeutic effect of extra high dose rate vs. standard dose rate irradiation on GSCs. GSCs were exposed to 2, 4 and 6 Gy X-irradiation at dose rates of 4.2 Gy/min or 21.2 Gy/min (400 monitoring units (MU)/min or 2100 MU/min). We analyzed cell survival with cell growth assays, tumorsphere formation assays and colony formation assays. Cell kill and self-renewal were dependent on the total dose of radiation delivered. However, there was no difference in survival of GSCs or DNA damage repair in GSCs irradiated at different dose rates. GSCs exhibited significant G1 and G2/M phase arrest and increased apoptosis with higher doses of radiation but there was no difference between the two dose rates at each given dose. In a GSC-derived preclinical model of glioblastoma, radiation extended animal survival, but there was no difference in survival in mice receiving different dose rates of radiation. We conclude that GSCs respond to larger fractions of radiation, but extra high dose rate irradiation has no significant biologic advantage in comparison with standard dose rate irradiation.

3 April 2025 in Cancers
Verified
Journal Article
Open access
PDF file
DWDa Wang
Da Wang
HKHeejung Kim
Heejung Kim
TZTingliang Zhuang
Tingliang Zhuang
JVJustin Visak
Justin Visak
BCBin Cai
Bin Cai
MLMu-Han Lin
Mu-Han Lin
Treatment planning in the field of radiation therapy has evolved from three-dimensional (3D) planning to inverse planning and, most recently, to personalized adaptive radiotherapy (ART)

8 December 2022 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
PDF file
ZXZhenyu Xiong
Zhenyu Xiong
YZYuncheng Zhong
Yuncheng Zhong
TBThomas I. Banks
Thomas I. Banks
RRRobert Reynolds
Robert Reynolds
TCTsuicheng Chiu
Tsuicheng Chiu
SSStrahinja Stojadinovic
Strahinja Stojadinovic
Objectives. The purpose of this study is to present data from the clinical commissioning of an Xstrahl 150 x-ray unit used for superficial radiotherapy, Methods. Commissioning tasks included vendor acceptance tests, timer reproducibility, linearity and end-effect measurements, half-value layer (HVL) measurements, inverse square law verification, head-leakage measurements, and beam output calibration. In addition, percent depth dose (PDD) curves were determined for different combinations of filter/kV settings and applicators. Automated PDD water phantom scans were performed utilizing four contemporary detectors: a microDiamond detector, a microSilicon detector, an EDGE detector, and a PinPoint ionization chamber. The measured PDD data were compared to the published values in BJR Supplement 25, Results. The x-ray unit’s mechanical, safety, and radiation characteristics were within vendor-stated specifications. Across sixty commissioned x-ray beams, the PDDs determined in water using solid state detectors were in excellent agreement with the BJR 25 data. For the lower (<100 kVp) and medium-energy (≥100 kVp) superficial beams the average agreement was within [−3.6,+0.4]% and [−3.7,+1.4]% range, respectively. For the high-energy superficial (low-energy orthovoltage) x-rays at 150 kVp, the average difference for the largest 20 × 20 cm2 collimator was (−0.7 ± 1.0)%, Conclusions. This study presents machine characterization data collected for clinical use of a superficial x-ray unit. Special focus was placed on utilizing contemporary detectors and techniques for the relative PDD measurements using a motorized water phantom. The results in this study confirm that the aggregate values published in the BJR 25 report still serve as a valid benchmark when comparing data from site-specific measurements, or the reference data for clinical utilization without such measurements, Advances in knowledge. This paper presents comprehensive data from the acceptance and commissioning of a modern kilovoltage superficial x-ray radiotherapy machine. Comparisons between the PDD data measured in this study using different detectors and BJR 25 data are highlighted.