René Schmiedler

René Schmiedler

Auto-generated profile, based on publicly available information

René Schmiedler

Institute of Medical Informatics, Charité – Universitätsmedizin Berlin , Berlin 10117

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2026 in medRxiv
Verified
Preprint
Open access
PDF file
FMFalk Meyer-Eschenbach
Falk Meyer-Eschenbach
RSRené Schmiedler
René Schmiedler
JSJohannes V. Stoephasius
Johannes V. Stoephasius
CZCamille Zhang
Camille Zhang
LKLuis Kronfli
Luis Kronfli
FBFelix Balzer
Felix Balzer
Objective: To systematically review and characterize methodological heterogeneity in sepsis case detection using the MIMIC-III and eICU-CRD databases. Materials and Methods: We conducted a PRISMA-guided systematic review of PubMed and Web of Science (publication years 2016–2024). We extracted methodological details on sepsis case detection across six domains: parameter coverage, temporal windows, aggregation methods, missing-data handling, SOFA calculation, and infection detection methods. For studies with available source code, we additionally examined code structure and repository dependencies to identify methodological decisions across these domains. Results: Of 396 publications screened, 64 met the inclusion criteria and 12 provided available source code. Sepsis detection rates ranged from 3.4% to 65.2% in MIMIC-III and from 9.8% to 47.9% in eICU-CRD. Substantial variability persisted among studies using identical cohort definitions within both databases (MIMIC-III: 16.9%–42.2%; eICU-CRD: 13.9%–31.4%). The overall proportion of studies reporting methodological details varied by domain: SOFA calculation (53.1%), infection detection methods (42.2%), temporal windows (37.5%), aggregation methods (26.6%) and missing-data handling (17.2%). Source code analysis identified 321 implementation decisions, revealing heterogeneity in baseline SOFA definitions (SOFA=0 vs dynamic baseline), temporal windows (infection-centered vs ICU-admission-centered) and infection detection methods (antibiotic-culture matching vs APACHE-based diagnosis). Dependencies among several MIMIC-III repositories suggested propagation of implementation decisions across studies. Discussion: Clinically validated sepsis definitions yield substantially different detection rates across studies using identical datasets, indicating heterogeneity in computational implementation. Conclusion: To improve reproducibility in sepsis research and the robustness of sepsis prediction models, we recommend standardized reporting of sepsis case detection methodology and the publication of version-controlled source code.

20 October 2026 in Journal of the American Medical Informatics Association
Verified
Journal Article
Open access
FMFalk Meyer-Eschenbach
Falk Meyer-Eschenbach
RSRené Schmiedler
René Schmiedler
JSJohannes von Stoephasius
Johannes von Stoephasius
CZCamille Zhang
Camille Zhang
LKLuis Kronfli
Luis Kronfli
FBFelix Balzer
Felix Balzer
Objective: To systematically review and characterize methodological heterogeneity in sepsis case detection using the Medical Information Mart for Intensive Care III (MIMIC-III) and eICU-CRD databases. Materials and Methods: We conducted a PRISMA-guided systematic review of PubMed and Web of Science (publication years 2016-2024). Studies were eligible if they applied the SOFA-based Sepsis-3 definition to MIMIC-III or eICU-CRD, provided at least one explicit label-calculation detail, reported a traceable detection rate, and met further criteria detailed in the PRISMA flow diagram. We classified each study by study type and unit of analysis (patients, admissions, or ICU stays) and extracted methodological details on sepsis case detection across 6 domains. For studies with available source code, we additionally examined code structure and repository dependencies to identify methodological decisions across these domains. Results: Of 396 publications screened, 64 met inclusion criteria and 12 provided source code. Sepsis detection rates ranged from 3.4% to 65.2% in MIMIC-III and from 9.8% to 47.9% in eICU-CRD. Substantial variability persisted among studies using identical cohort definitions within both databases (MIMIC-III: 16.9%-42.2%; eICU-CRD: 13.9%-31.4%). In a generalized linear mixed model, between-study heterogeneity was extreme (overall τ²≈0.79; 95% prediction interval for a new study’s detection rate 5%–63%), and study-level characteristics—including database, study type, infection detection method, code availability, and unit of analysis—explained only a small proportion of this variance (≈9%), with no characteristic reaching statistical significance. The overall proportion of studies reporting methodological details varied by domain: SOFA calculation (53.1%), infection detection methods (42.2%), temporal windows (37.5%), aggregation methods (26.6%), and missing-data handling (17.2%). Source code analysis identified 321 implementation decisions, revealing heterogeneity in baseline SOFA definitions (SOFA = 0 vs dynamic baseline), temporal windows (infection-centered vs ICU-admission-centered) and infection detection methods (antibiotic-culture matching vs APACHE-based diagnosis). Dependencies among several MIMIC-III repositories suggested propagation of implementation decisions across studies. Discussion: Clinically validated sepsis definitions yield substantially different detection rates across studies using identical datasets. Statistical modeling showed that this variability is driven almost entirely by between-study implementation differences rather than sampling error or study characteristics. Conclusion: To improve reproducibility in sepsis research and the robustness of sepsis prediction models, we recommend standardized reporting of sepsis case detection methodology and the publication of version-controlled source code.