Johannes von Stoephasius

Johannes von Stoephasius

Auto-generated profile, based on publicly available information

Johannes von Stoephasius

Institute of Informatics, Humboldt University, Berlin, Germany

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2026 in medRxiv
Verified
Preprint
Open access
PDF file
FMFalk Meyer-Eschenbach
Falk Meyer-Eschenbach
RSRené Schmiedler
René Schmiedler
JSJohannes V. Stoephasius
Johannes V. Stoephasius
CZCamille Zhang
Camille Zhang
LKLuis Kronfli
Luis Kronfli
FBFelix Balzer
Felix Balzer
Objective: To systematically review and characterize methodological heterogeneity in sepsis case detection using the MIMIC-III and eICU-CRD databases. Materials and Methods: We conducted a PRISMA-guided systematic review of PubMed and Web of Science (publication years 2016–2024). We extracted methodological details on sepsis case detection across six domains: parameter coverage, temporal windows, aggregation methods, missing-data handling, SOFA calculation, and infection detection methods. For studies with available source code, we additionally examined code structure and repository dependencies to identify methodological decisions across these domains. Results: Of 396 publications screened, 64 met the inclusion criteria and 12 provided available source code. Sepsis detection rates ranged from 3.4% to 65.2% in MIMIC-III and from 9.8% to 47.9% in eICU-CRD. Substantial variability persisted among studies using identical cohort definitions within both databases (MIMIC-III: 16.9%–42.2%; eICU-CRD: 13.9%–31.4%). The overall proportion of studies reporting methodological details varied by domain: SOFA calculation (53.1%), infection detection methods (42.2%), temporal windows (37.5%), aggregation methods (26.6%) and missing-data handling (17.2%). Source code analysis identified 321 implementation decisions, revealing heterogeneity in baseline SOFA definitions (SOFA=0 vs dynamic baseline), temporal windows (infection-centered vs ICU-admission-centered) and infection detection methods (antibiotic-culture matching vs APACHE-based diagnosis). Dependencies among several MIMIC-III repositories suggested propagation of implementation decisions across studies. Discussion: Clinically validated sepsis definitions yield substantially different detection rates across studies using identical datasets, indicating heterogeneity in computational implementation. Conclusion: To improve reproducibility in sepsis research and the robustness of sepsis prediction models, we recommend standardized reporting of sepsis case detection methodology and the publication of version-controlled source code.

15 November 2026 in medRxiv
Verified
Preprint
Open access
PDF file
FMFalk Meyer-Eschenbach
Falk Meyer-Eschenbach
JSJohannes V. Stoephasius
Johannes V. Stoephasius
ANAnatol-Fiete Näher
Anatol-Fiete Näher
FKFabian Kohlbacher
Fabian Kohlbacher
SKSeverin Kohler
Severin Kohler
OKOliver Kumpf
Oliver Kumpf
Objective: Published Sepsis-3 detection rates range from 3.4 % to 65.2 % in MIMIC-III and from 9.8 % to 47.9 % in eICU-CRD. We tested whether data preprocessing decisions alone produce differences of this magnitude when data, cohort and sepsis definition are held fixed. Materials and Methods: Using the MIMIC-III and eICU-CRD databases we developed and applied a configurable pipeline (medalabel) that stepwise maps the databases into the OMOP Common Data Model, standardizes and cleans the data, and preprocesses them to compute Sepsis-3 labels. Each setting of the preprocessing represents one decision of published Sepsis-3 implementations, and settings can be freely combined. On fixed cohorts of first ICU stays (13,388 in MIMIC-III, 94,782 in eICU-CRD), we changed one setting of a reference configuration at a time (51 variants in five preprocessing domains) and compared detection rates and septic stays (Jaccard index) with the reference. We approximately reconstructed six published pipelines and combined the settings with the largest effects in pairs to test whether their effects add up. The time a value is measured can differ from the time it is documented and thus available for automated analysis. Beyond the usual retrospective view based on measurement time, the pipeline optionally combines both time points to simulate a real-time system. Results: The reference configuration labelled 31.5 % of ICU stays in MIMIC-III and 8.2 % in eICU-CRD as septic. Changing a single setting resulted in sepsis detection rates of 15.3-58.6 % in MIMIC-III and 4.6-17.2 % in eICU-CRD. The largest shifts from the reference, all in the same direction in both databases, came from the SOFA baseline, up to +27.1 percentage points (pp) in MIMIC-III and +9.0 pp in eICU-CRD, from disabling imputation (-16.3 and -2.5 pp), the temporal window (+12.6 and +5.3 pp) and aggregation (-10.1 and -0.8 pp); clinician-validated parameter sets had little effect (-4.8 and -1.1 pp). Even variants that changed the rate by less than 2 pp labelled partly different patients, with Jaccard indices as low as 0.67 in MIMIC-III and 0.56 in eICU-CRD (1 = identical septic stays). Reconstructions deviated from the published rates by 2-10 pp. Two settings applied together deviated from the sum of their single effects by 0.9-11.8 pp in MIMIC-III and by up to 4.9 pp in eICU-CRD. Simulating a real-time system lowered the MIMIC-III rate by 5.0 pp and delayed the label in 45 % of the stays that remained septic. Discussion: With the infection criterion held fixed, preprocessing decisions alone can produce a considerable part of the variation between published sepsis detection rates. Similar rates can stem from different patients, which makes studies and prediction models difficult to compare, and retrospective labels rely on values that a real-time system would not yet have. Conclusion: Sepsis-3 labels from health records are only comparable if their data preprocessing is known. Configurable pipelines allow quantifying the effect of these decisions, computing alternative labels on the same data and, in future, validating them against clinician-adjudicated cases.

20 October 2026 in Journal of the American Medical Informatics Association
Verified
Journal Article
Open access
FMFalk Meyer-Eschenbach
Falk Meyer-Eschenbach
RSRené Schmiedler
René Schmiedler
JSJohannes von Stoephasius
Johannes von Stoephasius
CZCamille Zhang
Camille Zhang
LKLuis Kronfli
Luis Kronfli
FBFelix Balzer
Felix Balzer
Objective: To systematically review and characterize methodological heterogeneity in sepsis case detection using the Medical Information Mart for Intensive Care III (MIMIC-III) and eICU-CRD databases. Materials and Methods: We conducted a PRISMA-guided systematic review of PubMed and Web of Science (publication years 2016-2024). Studies were eligible if they applied the SOFA-based Sepsis-3 definition to MIMIC-III or eICU-CRD, provided at least one explicit label-calculation detail, reported a traceable detection rate, and met further criteria detailed in the PRISMA flow diagram. We classified each study by study type and unit of analysis (patients, admissions, or ICU stays) and extracted methodological details on sepsis case detection across 6 domains. For studies with available source code, we additionally examined code structure and repository dependencies to identify methodological decisions across these domains. Results: Of 396 publications screened, 64 met inclusion criteria and 12 provided source code. Sepsis detection rates ranged from 3.4% to 65.2% in MIMIC-III and from 9.8% to 47.9% in eICU-CRD. Substantial variability persisted among studies using identical cohort definitions within both databases (MIMIC-III: 16.9%-42.2%; eICU-CRD: 13.9%-31.4%). In a generalized linear mixed model, between-study heterogeneity was extreme (overall τ²≈0.79; 95% prediction interval for a new study’s detection rate 5%–63%), and study-level characteristics—including database, study type, infection detection method, code availability, and unit of analysis—explained only a small proportion of this variance (≈9%), with no characteristic reaching statistical significance. The overall proportion of studies reporting methodological details varied by domain: SOFA calculation (53.1%), infection detection methods (42.2%), temporal windows (37.5%), aggregation methods (26.6%), and missing-data handling (17.2%). Source code analysis identified 321 implementation decisions, revealing heterogeneity in baseline SOFA definitions (SOFA = 0 vs dynamic baseline), temporal windows (infection-centered vs ICU-admission-centered) and infection detection methods (antibiotic-culture matching vs APACHE-based diagnosis). Dependencies among several MIMIC-III repositories suggested propagation of implementation decisions across studies. Discussion: Clinically validated sepsis definitions yield substantially different detection rates across studies using identical datasets. Statistical modeling showed that this variability is driven almost entirely by between-study implementation differences rather than sampling error or study characteristics. Conclusion: To improve reproducibility in sepsis research and the robustness of sepsis prediction models, we recommend standardized reporting of sepsis case detection methodology and the publication of version-controlled source code.