4 August 2022 in IEEE Journal of Translational Engineering in Health and Medicine
Background: The hand motor function is lost and activities in daily life (ADLs) are affected due to some illnesses such as stroke and hemiplegia. As a coping way, we present a wearable rehabilitation glove with the bionic actuator for restoring the hand function and the motor control ability lost by stroke patients. Methods: The soft pneumatic bionic actuator (SPBA) is developed on the basis of the research of human hand bone structure and finger joint characteristics and a series of tests are conducted. Besides, we built the rehabilitation glove system based on the proposed SPBAs to verify the availability due to typical gesture, mirror therapy (MT) and grasping experiment for irregular objects. Result: The bending angle of SPBA can reach 260°. The output force of it can reach 5.1N with 0.25 MPa air pressure input. The maximum variance of the bending angle can be concluded at 5.1° in MT. The grasping experiments of the glove worn on the hand or not shows the proposed glove is flexible, the grip force is large and achieve stable grasping of objects. Conclusion: The designed SPBA is satisfied with the requirements of rehabilitation training and the proposed glove restore the normal hand motion of patients in ADLs.
8 June 2026 in IEEE Robotics and Automation Letters
Continuum robots show great potential in unstructured environments due to their superior safety and compliance compared to traditional articulated robots. However, their applications are limited by low load-bearing capacity and inter-segment actuation coupling. To address these issues, we propose a novel continuum robot featuring a triple-layer tendon system for intra-segment coupling and an inter-segment actuation decoupling structure. The coupling segment consists of serially connected spherical and socket joints with internal tendon channels. Triple-layer tendons pass through these channels, interconnecting the joints to enable synchronized motion from adjacent joints to the entire segment. For inter-segment decoupling, redirection pulleys are incorporated within the first two segments. Driving tendons for distal segments are routed through these pulleys and exit from the base segment to external actuators, ensuring independent motion of each segment. Experimental results demonstrate that the intra-segment coupling significantly enhances stiffness and load capacity. Motion experiments confirm effective spherical joint coupling and accurate bending angle tracking of sinusoidal references. The comprehensive experimental results of the three-segment continuum robot show that the segments have good decoupling performance and the robot possesses high repeatability positioning accuracy.