Hiroshi Shinotsuka

Hiroshi Shinotsuka

Auto-generated profile, based on publicly available information

Hiroshi Shinotsuka

National Institute for Materials Science

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

11 January 2010 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
Hiroshi AmekuraHiroshi Amekura
Hiroshi Amekura
MTM. Tanaka
M. Tanaka
YKY. Katsuya
Y. Katsuya
HYHiroshi Yoshikawa
Hiroshi Yoshikawa
HSH. Shinotsuka
H. Shinotsuka
Naoki KishimotoNaoki Kishimoto
Naoki Kishimoto
Zn nanoparticles at room temperature show two absorption peaks in the near-infrared (NIR) and the ultraviolet (UV) regions, both of which satisfy the criterion of surface plasmon resonance (SPR). From x-ray diffraction at high temperatures, it was found that the Zn nanoparticles in SiO2 melt at 360–420 °C and solidify at 250–310 °C with a large temperature hysteresis. While the NIR peak disappears with melting, the UV peak shows sudden energy shift with melting but survives even after the melting. The first-principle band calculation ascribes the UV and NIR peaks to SPR-enhanced inter- and intraband transitions, respectively.

31 January 2020 in Science and Technology of Advanced Materials
Verified
Journal Article
Open access
HSHiroshi Shinotsuka
Hiroshi Shinotsuka
KNKenji Nagata
Kenji Nagata
HYHideki Yoshikawa
Hideki Yoshikawa
YMYoh-ichi Mototake
Yoh-ichi Mototake
HSHayaru Shouno
Hayaru Shouno
MOMasato Okada
Masato Okada
We develop an automatic peak fitting algorithm using the Bayesian information criterion (BIC) fitting method with confidence-interval estimation in spectral decomposition. First, spectral decomposition is carried out by adopting the Bayesian exchange Monte Carlo method for various artificial spectral data, and the confidence interval of fitting parameters is evaluated. From the results, an approximated model formula that expresses the confidence interval of parameters and the relationship between the peak-to-peak distance and the signal-to-noise ratio is derived. Next, for real spectral data, we compare the confidence interval of each peak parameter obtained using the Bayesian exchange Monte Carlo method with the confidence interval obtained from the BIC-fitting with the model selection function and the proposed approximated formula. We thus confirm that the parameter confidence intervals obtained using the two methods agree well. It is therefore possible to not only simply estimate the appropriate number of peaks by BIC-fitting but also obtain the confidence interval of fitting parameters. Graphical abstract


31 January 2020 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Open access
PDF file
MSMineharu Suzuki
Mineharu Suzuki
HNHiroko Nagao
Hiroko Nagao
YHYoshitomo Harada
Yoshitomo Harada
HSHiroshi Shinotsuka
Hiroshi Shinotsuka
KWKatsumi Watanabe
Katsumi Watanabe
HYHideki Yoshikawa
Hideki Yoshikawa
The National Institute for Materials Science, Japan, has been developing a materials data platform linked with a materials data repository system for rapid new material searching using materials informatics. Data conversion from raw data to a human-legible/machine-readable data file is one of the key preparation techniques prior to data analysis, where the converted data file should include metainformation. The tools developed by the authors can convert raw data to a structured data package that consists of mandatory and measurement-characterization metadata, primary and raw parameters, and formatted numerical data (FND). The FND are expressed as a matrix type with robust flexibility. This flexibility is achieved by applying the data analysis architecture of schema-on-read, not schema-on-write based on de jure standards, such as ISO documents. The primary parameters are carefully selected from raw parameters, and their vocabularies are transformed from instrument-dependent terms to general terms that everyone can readily understand. The converted data are linked with, for example, specimen information, process information, specimen handling records, and the electronic laboratory notebook. Using this raw-to-repository (R2R) conversion flow, the authors demonstrated that they can generate and store interoperable data files of x-ray photoelectron spectroscopy (XPS) spectra and depth profiles, powder x-ray diffraction patterns, (scanning) transmission electron microscope images, transmission electron diffraction patterns, electron energy-loss spectroscopy spectra, and calculated electron inelastic mean free path data. Linking measurement data to other required information ensures experimentally repeatable, replicable, and reproducible results. The mandatory and characterization metadata are used for quick electronic searching, and primary and raw parameters are convenient for setting up measurement conditions and useful for reproducibility/replicability and replicability/repeatability, respectively. The FND are human legible and machine readable using parser software, leading to a long lifetime of data utilization. The authors also developed a system to allow the semiautomatic data transfer from an instrument-controlling personal computer (PC) isolated from the communication network by adopting a Wi-Fi-capable secure digital card’s scripting capability while keeping the PC offline. They are developing further software for on-demand data manipulation after R2R data conversion. To date, it has been possible to perform XPS peak separation using an automated information compression technique without any a priori assumption. By combining R2R conversion with a high-throughput data collection system and automated data analysis routine, highly reproducible data acquisition and data analysis could be achieved, where human interaction is minimized. At this early stage, the authors demonstrate automated peak separation processing for XPS C 1s and O 1s narrow spectra of polyethylene terephthalate with very high reproducibility.

2 May 2022 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
BDB. Da
B. Da
XLX. Liu
X. Liu
LYL. H. Yang
L. H. Yang
JGJ. M. Gong
J. M. Gong
ZDZejun Ding
Zejun Ding
STS. Tanuma
S. Tanuma
This work investigates the detailed difference between dielectric function models, the Mermin model and the full Penn algorithm (FPA) model, for the determination of an electron inelastic mean free path (IMFP) with optical energy loss function (ELF), as an extension of our previous study [Da et al., Surf. Interface Anal. 51, 627 (2019)] by using the simple Drude-type ELF. In the conventional normal Mermin (NM) model, the approximations of ELF by the Drude equation will introduce inevitable fitting error. In order to enhance the accuracy of the NM model, our previous proposed extended Mermin model [Da et al., Phys. Rev. Lett. 113, 063201 (2014)], which is renamed as a super-extended Mermin algorithm (SE-MA) now, is employed to eliminate the error by expanding the definition of Drude oscillators used in the NM. In the SE-MA, the Drude-like oscillators allow the existence of negative strengths to express the fine structures of phonon–electron scattering and the plasmon lifetime broadening effect. Because in our previous study, the simple Drude-type ELF cannot include these complex structures, in this work, the electron IMFPs are calculated for five realistic materials, Al, Si, Cu, Au, and MgO. The difference between IMFPs calculated by the SE-MA model and the FPA model is material dependent and is significant in the low energy region, which is analyzed by using the Fano plot. This is due to the more important role played by the plasmon lifetime broadening effect.