14 December 2022 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
There is growing evidence on the efficacy of electrical stimulation delivered via spinal neural interfaces to improve functional recovery following spinal cord injury. For such interfaces, carbon-based neural arrays are fast becoming recognized as a compelling material and platform due to biocompatibility and long-term electrochemical stability. Here, we introduce the design, fabrication, and in vivo characterization of a novel cervical epidural implant with carbon-based surface electrodes. Through finite element analysis and mechanical load tests, we demonstrated that the array could safely withstand loads applied to it during implantation and natural movement of the subject with minimal stress levels. Furthermore, the long-term in vivo performance of this neural array consisting of glassy carbon surface electrodes was investigated through acute and chronic spinal motor evoked potential recordings and electrode impedance tests in rats. We demonstrated stable stimulation performance for at least four weeks in a rat model of spinal cord injury. Lastly, we found that impedance measurements on all carbon-based spinal arrays were generally stable over time up to four weeks after implantation, with a slight increase in impedance in subsequent weeks when tested in spinally injured rats. Taken together, this study demonstrated the potential for carbon-based electrodes as a spinal neural interface to accelerate both mechanistic research and functional restoration in animal models of spinal cord injury.
19 August 2025 in Lab on a Chip
The O2C securely seals the open microchannels of the CandyCollect device to create a continuous closed channel for seamless delivery of elution reagents to release antigens at the press of a button for subsequent lateral flow detection.
11 February 2025 in bioRxiv
We created CandyCollect, a lollipop-inspired, child-friendly saliva sampling device that provides enhanced comfort compared to common throat and mouth swabs. The device has an open microchannel and a functionalized surface that effectively captures and stores the saliva and pathogens. We recently demonstrated the ability to combine the CandyCollect with rapid antigen detection tests (RADTs) for fast and accessible detection of group A streptococcus (GAS). However, the current procedure necessitates manual steps to elute and transfer captured antigens from the lollipop to RADTs, which relies on the user to follow complex instructions, increasing the likelihood of error. In this work, we developed the CandyCollect Open to Closed (O2C) microfluidic system to automate antigen elution and streamline detection with RADTs. The O2C system securely seals the open microchannels of the CandyCollect device to create a continuous closed channel for seamless delivery of elution reagents to release antigens at the press of a button for subsequent lateral flow detection. Our system leverages and combines the unique benefits of both open channel and closed channel microfluidics into one platform, further enhancing the potential of both methods. We performed experiments with GAS bacteria spiked into saliva and compared the manual and O2C elution methods. Both the manual and O2C methods showed clear test lines on the RADT strips at clinically relevant GAS concentrations (between 5 ×10 5 and 10 9 CFU/mL). The O2C provided comparable or better results than the manual procedure in a more convenient form factor. The O2C platform has the potential to enable user-friendly screening for respiratory pathogens by minimally trained users in decentralized settings.