10 July 2024 in IEEE Open Access Journal of Power and Energy
This study focuses on analyzing switching transients in the upcoming 500 kV Java-Bali Connection (JBC) hybrid OHL and submarine cable project using DIgSILENT PowerFactory software, based on a realistic power system model. Distributed-parameter models with constant parameters of the Bergeron model are utilized. Analysis of the traveling wave effect on the line is conducted, and the integration time step based on the time of the traveling wave is carefully selected. Statistical distributions of energization are produced by varying the circuit configuration and system short-circuit power. It is found that the Switching Withstand Voltage (SWV) during the energization process remain below 1175 kV. The probability distribution is fitted to a normal distribution, with the skewness and kurtosis shown to be skewed to the right and having a lower peak than that of the normal distribution, respectively. When a three-phase short-circuit at the line breaker is induced, the rate of rise of recovery voltage (RRRV) exceeds the IEC standard envelope if only one circuit is operating. In this contribution, switching analysis during no-load energization and de-energization in the planning stage of the mixed OHL-submarine cable is examined.
10 September 2025 in IEEE Access
This article proposes a method for determining the optimal reclose scheme in power systems. The proposed approach involves analyzing multiple parameters such as the voltage and phase angle difference between bus, critical clearing time (CCT) of the systems, power surge of connected generators in the system, secondary arc duration in the systems, fault-induced delayed voltage recovery (FIDVR) phenomenon, and transient recovery voltage (TRV) in circuit breaker. Each parameter is assessed individually, and the results are compared with a matrix scoring system to determine the appropriate reclose scheme for each parameter. Subsequently, the reclose schemes derived from each parameter are integrated to identify the most effective reclose scheme for each segment of the system. This approach ensures that all relevant factors are considered in selecting a reclose scheme that optimally balances the system’s stability, reliability, and performance under various conditions. This methodology provides a more robust reclose scheme by considering a comprehensive set of factors, leading to enhanced the system stability and reliability. This study utilized DIgSILENT PowerFactory, providing a detailed examination of the Batam-Bintan transmission system. It is shown that the proposed method shortens the deadtime by 2 seconds in most single-phase reclosing schemes and 1 three-phase scheme, and mitigates the system instability risk on 3 three-phase reclosing schemes. The method presented serves as a valuable guide for determining optimal reclose schemes in both distribution and transmission systems, contributing to more effective fault recovery strategies and improved network performance.