Metal artifacts present a challenge to cone-beam CT (CBCT) image-guided surgery, obscuring visualization of metal instruments and adjacent anatomy—often in the very region of interest pertinent to the imaging/surgical tasks. We present a method to reduce the influence of metal artifacts by prospectively defining an image acquisition protocol—viz., the C-arm source-detector orbit—that mitigates metal-induced biases in the projection data. The metal artifact avoidance (MAA) method is compatible with simple mobile C-arms, does not require exact prior information on the patient or metal implants, and is consistent with 3D filtered backprojection (FBP), more advanced (e.g. polyenergetic) model-based image reconstruction (MBIR), and metal artifact reduction (MAR) post-processing methods. The MAA method consists of: (i) coarse localization of metal objects in the field-of-view (FOV) via two or more low-dose scout projection views and segmentation (e.g. a simple U-Net) in coarse backprojection; (ii) model-based prediction of metal-induced x-ray spectral shift for all source-detector vertices accessible by the imaging system (e.g. gantry rotation and tilt angles); and (iii) identification of a circular or non-circular orbit that reduces the variation in spectral shift. The method was developed, tested, and evaluated in a series of studies presenting increasing levels of complexity and realism, including digital simulations, phantom experiment, and cadaver experiment in the context of image-guided spine surgery (pedicle screw implants). The MAA method accurately predicted tilted circular and non-circular orbits that reduced the magnitude of metal artifacts in CBCT reconstructions. Realistic distributions of metal instrumentation were successfully localized (0.71 median Dice coefficient) from 2–6 low-dose scout views even in complex anatomical scenes. The MAA-predicted tilted circular orbits reduced root-mean-square error (RMSE) in 3D image reconstructions by 46%–70% and ‘blooming’ artifacts (apparent width of the screw shaft) by 20–45%. Non-circular orbits defined by MAA achieved a further ∼46% reduction in RMSE compared to the best (tilted) circular orbit. The MAA method presents a practical means to predict C-arm orbits that minimize spectral bias from metal instrumentation. Resulting orbits—either simple tilted circular orbits or more complex non-circular orbits that can be executed with a motorized multi-axis C-arm—exhibited substantial reduction of metal artifacts in raw CBCT reconstructions by virtue of higher fidelity projection data, which are in turn compatible with subsequent MAR post-processing and/or polyenergetic MBIR to further reduce artifacts.
Background Acute kidney injury (AKI) is a frequent complication associated with on-pump cardiac surgery. Early recognition may alter their prognosis. Therefore, the urinary concentrations of TIMP-2 (tissue inhibitor of metalloproteinases-2) and IGFBP7 (insulin-like growth factor-binding protein) as predictors for AKI were studied. Methods Repetitive blood and urine samples were collected consecutively from 50 patients. Demographic, intra-, and postoperative data were recorded prospectively. To calculate the production of the TIMP-2 and IGFBP-7 protein concentrations, urinary samples were taken preoperatively, intraoperatively at 30 and 60 min after aortic clamping and at 0, 6, 12, and 24 h after admission to the intensive care unit (ICU). Results AKI occurred in 14 patients (28%), all of them at Kidney Disease: Improving Global Outcomes stage 1. Predictive value for [TIMP-2] × [IGFBP7] was shown at 0 and 24 h after admission to ICU. At 0 h, the sensitivity was 84.6% and the specificity 55.6% for an ideal calculated cutoff at 0.07. After 24 h, the ideal cutoff amounted to 0.35 with a sensitivity of 53.8% and a specificity of 88.2%. The receiver operating characteristic curves demonstrated areas under the curve of 0.725 and 0.718. The suggested cutoffs of 0.3 and 2.0 could not be confirmed. The serum creatinine was reached to the peak median within 48 h after admission to ICU. Conclusion Postoperative risk assessment for the development of AKI can be established by . Previously suggested cutoff values could not be confirmed. A correlation with urinary dilution parameters may enable the identification of more universal cutoffs.
OBJECTIVE. The purpose of this study was to assess the accuracy of 64-MDCT in the visualization of different coronary artery stents and in the appraisal of in-stent stenosis. MATERIALS AND METhODS. Five different coronary stent types with three diameters (2.5, 3.0, and 4.0 mm) were analyzed using anthropomorphic dynamic cardiac phantom. All stents were mounted on polyurethane sticks of defined outer diameter and contained a default concentric stenosis of 50% each. Imaging was performed at four different heart rates (no motion, 60 beats/min, 75 beats/min, and 90 beats/min). Apparent stent diameter, degree of stenosis, in-stent attenuation, and diagnostic accuracy were assessed. RESULTS. A significant (p < 0.05) overestimation of the degree of stenosis (41.1% ± 41.4%), underestimation of the stent lumen (−42.7% ± 41.4%), and increase in in-stent attenuation (36.6 ± 29.2 HU) were observed for all stents and heart rates. In-stent stenosis > 50% was detected with an overall sensitivity of 88.9% (95% CI, 75.9–96.3%) and an overall specificity of 51.1% (95% CI, 35.8–66.3%) by observer 1 and with an overall sensitivity of 86.7% (95% CI, 73.2–94.9%) and an overall specificity of 57.8% (95% CI, 42.2–72.3%) by observer 2. A trend toward higher specificity was observed for increasing stent diameter, however, without reaching statistical significance (p = 0.63). CONCLUSION. In an experimental setting, 64-MDCT allows a reliable detection of instent stenosis but significantly overestimates the actual degree of stenosis. Within the range of physiologic heart rates, diagnostic accuracy is restricted by spatial, not temporal, resolution.