21 May 2018 in IEEE Transactions on Industry Applications
With the increasing number of electric locomotives and electric multiple units (EMU) operating in one power section simultaneously, low frequency oscillation (LFO) may occur. LFO may cause serious railway accidents, which will seriously influence the stable operation of the power system. In this paper, LFO is solved by establishing a simplified mathematical model of the generalized EMU and a dq-decoupled small-signal model of the single-phase pulse width modulation rectifier. Then an Improved Forbidden-Region Criterion (IFRC) is proposed to analyze the stability of the train-grid system and a comparison of the classical criteria is listed to show the advantages of the IFRC. The proposed criterion has less conservatism and higher accuracy than the recently proposed Forbidden-Region-Based Criterion (FRBC), which has better performance than the classical criteria. Moreover, the analysis result is successfully reproduced by establishing the time-domain simulation model in MATLAB/Simulink and RT-LAB, which verifies the effectiveness and accuracy of the proposed criterion. Finally, the development of IFRC shows the influence of gird-side parameters, traction-side parameters and control parameters of train-grid system. Several ways to suppress the LFO are provided according to the simulation results.
27 March 2019 in IEEE Transactions on Industry Applications
The instantaneous power for three-phase rectifier can be calculated directly in the orthogonal coordinate system via coordinate transformation. However, it is difficult to calculate the instantaneous power directly for single-phase rectifier due to the lack of another phase. Therefore, an orthogonal signal generator (OSG) is required to create an orthogonal coordinate system. Currently, conventional OSG algorithms suffer from long response time. To remedy this problem, in this paper, an arbitrary phase-delay OSG algorithm is developed and applied to the direct power control system in the single-phase rectifiers. Firstly, the instantaneous power theory and direct power control are presented. Then, the principle of the arbitrary phase-delay OSG method is introduced and the anti-interference ability of the proposed method is analyzed. Through the dynamic response analysis, the developed algorithm brings faster response, easier implementation and less computational burden compared with other common OSG algorithms. Finally, the validity and advancement of the proposed algorithm are verified by simulations and hardware-in-loop experimental tests. A comparison with conventional OSG algorithms also proves the advantages of the developed method.
9 February 2021 in Frontiers in Energy Research
For urban electrical and thermal energy supply and consumption terminals, the multi-energy system is a way to realize the energy conversion and consumption efficiently, cleanly and economically. To further study the power flow character of multi-energy systems, additional factors such as electric-thermal coupling equipment, thermal flow rules should be taken into consideration. The traditional Newton-Raphson iteration method which has been commonly used for electrical power flow calculation must be expanded to electric-thermal mixed power flow. This paper realized a new expression of hot water temperature drop with the thermal supply pipe network. This expression modified the Sukhov cooling operator and intuitively revealed the impact factor of transmission loss in hot water pipes. As a result, mathematical descriptions of electricity, heat and hydraulic flow in a multi-energy system were established. With the modified Sukhov cooling operator, the mathematical model of the expanded Newton-Raphson fast iterative solution algorithm, together with its Jacobian matrix elements affected by the electro-thermal coupling relationship was derived. A regional electric-heat supply system was selected as an example to verify the effectiveness of the method. Results showed that the transmission loss in electrical grid is related with the power load while in thermal pipes it was mainly related with the ambient temperature.