4 February 2022 in IEEE Transactions on Biomedical Engineering
The mechanical and electrical properties of soft tissues are relative to soft tissues’ pathological state. Modern medical imaging devices have shown a trend to multi-modal imaging, which will provide complementary functional information to improve the accuracy of disease diagnosis. However, no method or system can simultaneously measure the mechanical and electrical properties of the soft tissue. In this study, we proposed a novel dual-modal imaging method integrated by shear wave elasticity imaging (SWEI) and Magneto-acousto-electrical tomography (MAET) to measure soft tissue's elasticity and conductivity simultaneously. A dual-modal imaging system based on a linear array transducer is built, and the imaging performances of MAET and SWEI were respectively evaluated by phantoms experiment and in vitro experiment. Conductivity phantom experiments show that the MAET in this dual-modal system can image conductivity gradient as low as 0.4 S/m. The phantom experiments show that the reconstructed 2-D elasticity maps of the phantoms with inclusions with a diameter larger than 5 mm are relatively accurate. In vitro experiments show that the elasticity parameter can significantly distinguish the changes in tissue before and after heating. This study first proposes a method that can simultaneously obtain tissue elasticity and electrical conductivity to the best of our knowledge. Although this paper just carried out the proof of concept experiments of the new method, it demonstrates great potential for disease diagnosis in the future.
8 November 2022 in IEEE Transactions on Biomedical Engineering
As a tissue conductivity imaging method, magneto-acousto-electric tomography (MAET) has the advantage of high axial spatial resolution compared with traditional electrical impedance imaging methods. However, it has the problems of difficulty in imaging targets with irregular conductivity distribution and poor lateral spatial resolution. Although the rotation-based MAET method can partly solve the irregular target problem, there is still a poor imaging signal-to-noise ratio (SNR) problem. Our previous study established a framework of an innovative MAET method, which has a very similar imaging theory and reconstruction algorithm to those of computed tomography (CT). Therefore, we name the method magneto-acoustic-electric computed tomography (MAE-CT). This paper proposes an improved implementation of MAE-CT based on multi-angle plane wave excitation. This method combines the electronic steering of the linear array transducer with the mechanical rotation to increase the number of projection angles while keeping the imaging complexity. In this study, we first established a finite element simulation model to verify the method's feasibility. Then phantom experiments were conducted to systematically investigate the performance of the proposed method. Finally, in vitro liver tissue experiment was conducted to further explore the feasibility of the method. The experimental results show that our method improves both the SNR and spatial resolution of the reconstructed image. For the phantom results, this method can detect conductivity of 0.67 S/m in an area with a size of 2 mm. To the best of our knowledge, this is the best result of spatial resolution available for MAET.
12 September 2023 in IEEE Transactions on Biomedical Engineering
Magneto-acousto-electrical computed tomography (MAE-CT) is a recently developed rotational magneto-acousto-electrical tomography (MAET) method, which can map the conductivity parameter of tissues with high spatial resolution. Since the imaging mode of MAE-CT is similar to that of CT, the reconstruction algorithms for CT are possible to be adopted for MAE-CT. Previous studies have demonstrated that the filtered back-projection (FBP) algorithm, which is one of the most common CT reconstruction algorithms, can be used for MAE-CT reconstruction. However, FBP has some inherent shortcomings of being sensitive to noise and non-uniform distribution of views. In this study, we introduced iterative reconstruction (IR) method in MAE-CT reconstruction and compared its performance with that of the FBP. The numerical simulation, the phantom, and in vitro experiments were performed, and several IR algorithms (ART, SART, SIRT) were used for reconstruction. The results show that the images reconstructed by the FBP and IR are similar when the data is noise-free in the simulation. As the noise level increases, the images reconstructed by SART and SIRT are more robust to the noise than FBP. In the phantom experiment, noise and some stripe artifacts caused by the FBP are removed by SART and SIRT algorithms. In conclusion, the IR method used in CT is applicable in MAE-CT, and it performs better than FBP, which indicates that the state-of-the-art achievements in the CT algorithm can also be adopted for the MAE-CT reconstruction in the future.
16 July 2024 in IEEE Transactions on Biomedical Engineering
Magneto-acousto-electrical tomography (MAET) is a hybrid imaging method that combines the high spatial resolution of ultrasonography with the high contrast of electrical impedance tomography (EIT). While most previous studies on MAET have focused on two-dimensional imaging, our recent research proposed a novel three-dimensional (3D) MAET method using B-mode and translational scanning. This method has been the first to reconstruct a 3D volume image of conductivity interfaces. However, this method has its limitations in mapping irregular shapes of conductivity. To address this challenge, we propose a 3D magneto-acousto-electrical computed tomography (3D MAE-CT) method utilizing an ultrasound linear array transducer in this work. Both phantom and in vitro experiments were conducted to validate our proposed method. The results from the phantom experiments demonstrate that our method can map the 3D volume conductivity with high spatial resolution. The oblique angles extracted from the 3D image closely match practical value, with the relative error ranging between −2.80% and 4.07%. Furthermore, the in vitro experiment successfully obtained a 3D image of a chicken heart, marking the first MAET 3D conductivity image of a tissue sample to date.
20 March 2025 in IEEE Transactions on Instrumentation and Measurement
Magneto-acousto-electrical tomography (MAET), which combines ultrasound imaging with electrical impedance tomography, offers high resolution and high contrast for mapping the internal conductivity distribution of an object. However, it is a challenge to reconstruct the conductivity distribution containing the interior information due to practical system constraints. A significant issue is the limited bandwidth of experimental systems, especially the ultrasound transducer, which can filter out low-frequency components of the measurement signal. Inspired by the multi-compartment model paradigm in diffusion MRI, we propose an innovative model-based approach to address this conductivity reconstruction challenge. The object’s conductivity is constrained by the weighted sum of shifted jump models, dramatically reducing the problem’s degrees of freedom. By deriving the measurement signal based on the proposed model, we can extract the conductivity polarity using an overdetermined linear system solved by the least-squares method. Furthermore, by integrating amplitude information from conventional conductivity parameter images with the extracted conductivity polarity, we reconstruct the final relative conductivity distribution. Our methodology has been rigorously tested through numerical simulations with various noise levels (20%, 40%, and 60%), phantom experiments, and pork tissue comparisons against the state-of-the-art method. The results demonstrate that our method offers superior accuracy and stability compared to existing techniques in case of all evaluation metrics RMSE, SSIM, PSNR. In conclusion, our proposed method is straightforward to implement and applicable in both simulations and practical experiments, providing a potential strategy for conductivity reconstruction in complex objects in the future.