Investigation of space charge accumulation processes in a chemically cross-linked polyethylene for ac usage (XLPE) and a modified XLPE for dc usage (DC-XLPE) at voltage polarity reversal was carried out using pulsed electro-acoustic (PEA) measurement system. We found that a huge amount of so called packet-like charge, some of which partially increased the electric field in the material to more than twice of the average applied stress, generated in XLPE at the polarity reversal of DC stress. It enhanced the electric stress locally in the sample by almost twice of the applied average stress. On the other hand, we also found that the packet-like charge was not observed in DC-XLPE under the same experimental condition.
This paper reports the synthesis of D-A polymers containing 1,2-dithienylethene (DTE) units via palladium-catalyzed direct arylation polymerization (DArP). The reaction of dibromoisoindigo (1-Br) and DTE (2-H), in the presence of Pd2(dba)3·CHCl3 (0.5 mol%), P(2-MeOC6H4)3 (L1) (2 mol%), pivalic acid (1 equiv) as catalyst precursors, and Cs2CO3 (3 equiv) as a base affords poly(1-alt-2) with a high molecular weight (Mn up to 44,900). Although, it has been known that monomers, with plural C–H bonds, tend to form insoluble materials via direct arylation at undesirable C–H positions; the reaction of 1-Br and 2-H cleanly proceeds without insolubilization. The resulting polymer has a well-controlled structure and exhibits good charge transfer characteristics in an organic field-effect transistor (OFET), compared to the polymer produced by Migita–Kosugi–Stille cross-coupling polymerization. The DArP product displays an ideal linear relationship in the current–voltage curve, whereas the Migita–Kosugi–Stille product shows a VG-dependent change in the charge mobility.
An optical method to resolve the non-measurable thickness problem caused by the overlap of optical path differences within a specific thickness range when measuring the physical thickness of a sample using a spectral-domain interferometer is proposed and realized. Optical path differences can be discerned by inserting a correction glass piece into the measurement path, thus increasing the measurement optical path length. To verify the proposed method, 0.2-mm-thick N-BK7 glass was used as a sample, with physical thickness and group refractive index measurements conducted according to three different correction glass elements with corresponding nominal thicknesses of 3.0 mm, 3.5 mm, and 4.0 mm. Through uncertainty evaluations according to the correction glass used, the physical thicknesses of the sample were found to be in good agreement within measurement uncertainties of less than 100 nm, results comparable to those of previous works which did not use any correction glass.