Pelin Uslu Kiçeci

Pelin Uslu Kiçeci

Auto-generated profile, based on publicly available information

Pelin Uslu Kiçeci

Department of Physics, Middle East Technical University (METU), Ankara, Turkey

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2022 in Eurasian Journal of Science Engineering and Technology
Verified
Journal Article
Closed access
AAAbdulrahman Albarodi̇
Abdulrahman Albarodi̇
PKPelin Uslu Ki̇çeci̇
Pelin Uslu Ki̇çeci̇
SDselcen uzun duran
selcen uzun duran
BDBilge Demi̇rköz
Bilge Demi̇rköz
Neutron shielding is of utmost importance in radiation environments such as nuclear reactors and particle accelerators and in fields such as health physics. In this work, the percentages of neutrons stopped by shields comprising of boron minerals (HDPE/B2O3, Epoxy/Priceite, Epoxy/Colemanite, Epoxy/Kernite) in their composition against neutron radiation of different energies is investigated using two separate MC simulations. Different layer combinations of epoxy based borated shielding materials with HDPE sheets were then simulated to find the optimum shielding configuration. In addition, radioactivation studies were carried out for these designs. The most suitable design was found to be the layered setup of the HDPE sheet and the epoxy/colemanite composite sheet for mixed neutron energies (

31 March 2022 in Radiation Effects and Defects in Solids
Verified
Journal Article
Closed access
PKPelin Uslu Kiçeci
Pelin Uslu Kiçeci
MAM. Vedat Akdeniz
M. Vedat Akdeniz
MDM. Bilge Demirköz
M. Bilge Demirköz
AMAmdulla Mekhrabov
Amdulla Mekhrabov
The selection of appropriate materials for radiation environments is critical due to the harsh and aggressive conditions found in such environments, which are liable to degrade material properties. Therefore, durability of materials should be tested before being deployed. In this respect, proton tests are required for the materials to be used in the space environment because dominant galactic cosmic rays mostly comprised high energy protons. Bulk metallic glasses are candidate for space environment due to their desirable properties such as high strength, high corrosion resistance, and lack of grain boundaries. In this present study, we report the effect of a 30 MeV proton beam irradiation on the structural, thermal, mechanical, and magnetic properties of partially crystalline bulk amorphous Fe-based metallic glass. Defect size increment in positron annihilation lifetime spectroscopy and small intensity changes on the X-ray diffraction peaks of samples were observed after the irradiation that can be attributed to increasing free volumes. In addition, changes in crystallisation and glass transition temperatures were examined in differential scanning calorimetry. Furthermore, rise in coercivity which is a magnetic property was observed in vibrating sample magnetometer that may associate with the defect size increment. On the other hand, any changes were not observed on the microhardness measurements.

12 April 2021 in Nuclear Technology
Verified
Journal Article
Closed access
SDselcen uzun duran
selcen uzun duran
PKPelin Uslu Kiçeci
Pelin Uslu Kiçeci
BDBilge Demirköz
Bilge Demirköz
The Middle East Technical University Defocusing Beamline (METU-DBL) is being constructed in order to perform single event effects tests for the electronic components in accordance with the European Space Agency (ESA) European Space Components Coordination (ESCC) No. 25100 standard. The aim of this beamline is to provide a suitable test area at the end of the beamline using the beam elements, such as collimators and magnets. Shielding is a crucial precaution for the safety of the radiation workers and the protection of the electronic components from the detrimental effects of radiation. In the METU-DBL, shielding studies have started with the first protective collimator because the proton beam hits the collimator, resulting in secondary particle production that increases the dose level in the research and development (R&D) room. The shielding studies of the first protective collimator used in the pretest setup of the METU-DBL are presented in this study. The whole beamline was defined in the FLUKA simulation program to calculate the absorbed radiation dose and make shielding designs. Various shielding designs were studied in FLUKA and the 15th one was selected as a suitable shielding design for the first protective collimator. This shield was manufactured and mounted on the first protective collimator and used in 20 irradiations during the pretests. At the end of 20 irradiations, it was observed that the shield is effective at decreasing the dose level in the R&D room.

1 December 2023 in Gazi University Journal of Science
Verified
Journal Article
Open access
PDF file
MDMelahat Bilge Demi̇rKöz
Melahat Bilge Demi̇rKöz
PKPelin Uslu Ki̇çEci̇
Pelin Uslu Ki̇çEci̇
SDselcen uzun duran
selcen uzun duran
Electronic components must be tested to allow for safe and reliable missions in radiation environments. The METU Defocusing Beamline (METU-DBL) was installed in the R&D room at the Particle Accelerator Facility (PAF) of Turkish Energy, Nuclear and Mineral Research Agency (TENMAK). This facility was established in accordance with the European Space Agency (ESA), European Space Components Coordination (ESCC), No: 25100 standard to conduct proton irradiation tests for electronic components and various materials to be used in the space environment. METU-DBL uses beam elements such as quadrupole magnets to amplify the beam and collimators to reduce the flux, as per the specifications of the standard.A pretest setup was constructed, and this system was operated for a total of 17 hours for three months before the METU-DBL final design was assembled. The first protective collimator is made of stainless steel 316L and was used during the period of pretests. As a result of these irradiations, the emerged radioisotopes in the collimator were observed and measured in situ with a NaI detector. These measurements were compared with the FLUKA simulations 120 days after the last irradiation. Among fourteen radioisotopes, only six of them with activity above 1.0×101 Bq/cm3 were matched.