Javier González-Pérez

Javier González-Pérez

Auto-generated profile, based on publicly available information

Javier González-Pérez

Ocular Surface and Contact Lens Research Laboratory, Faculty of Optics and Optometry, Universidade de Santiago de Compostela, Spain

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2012 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
JGJavier González-Pérez
Javier González-Pérez
CVCésar Villa-Collar
César Villa-Collar
Tomas SobrinoTomas Sobrino
Tomas Sobrino
MLMaría Isabel Lema-Gesto
María Isabel Lema-Gesto
JGJosé M. Gonzalez-Méijome
José M. Gonzalez-Méijome
MPManuel Parafita
Manuel Parafita
Objectives To study changes in tear film inflammatory mediators following continuous wear of silicone-hydrogel lenses and corneal refractive therapy with reverse geometry contact lenses. Design A prospective, case–control study. Methods Twenty-eight subjects had worn silicone-hydrogel lenses on a 30-night continuous wear basis. Thirty-two subjects had worn corneal refractive therapy lenses on an overnight basis. Thirty-two matched control subjects were also recruited. Tear samples were obtained 12 months after initial fitting and assayed using ELISA for cytokines (interleukin (IL)-6 and IL-8), matrix metalloproteinase 9 (MMP-9) and epidermal growth factor (EGF). Results EGF was significantly increased 12 months after both interventions. IL-6, IL-8 and MMP-9 were significantly increased only after corneal refractive therapy. The inflammatory response for the corneal refractive therapy patients was found to be associated with the degree of myopia corrected and the presence of corneal staining. Moreover, an increased level of MMP-9 and EGF was found to be associated with the presence of corneal-pigmented arc in the corneal refractive therapy group. Conclusions This research showed long-term increased tear levels of inflammatory markers in subjects wearing corneal refractive therapy lenses when compared with continuous wear of silicone-hydrogel lenses or no lens wear.

1 April 2004 in Eye & Contact Lens: Science & Clinical Practice
Verified
Journal Article
Closed access
JPJavier González Pérez
Javier González Pérez
Alejandro CerviñoAlejandro Cerviño
Alejandro Cerviño
MFMaría Jesús Giráldez Fernández
María Jesús Giráldez Fernández
MPM. Parafita
M. Parafita
EYE. Yebra-Pimentel
E. Yebra-Pimentel
It is important to know how well the surface topography can be measured with current devices for corneal topographic analysis. There are several applications that need an accurate and precise method to measure corneal shape and variations, such as the effect of contact lens wear and the different refractive surgery techniques. The aim of this study is to compare the accuracy and reproducibility of the measurement of the central curvature on calibrated steel balls using the EyeSys videokeratoscope and the Orbscan corneal topography system. The videokeratoscope (EyeSys Corneal Analysis System 2000, version 3.1) and the Orbscan corneal topography system (Orbscan II version 3.0) were used by four trained investigators to measure a series of five uniform and calibrated test surfaces with known radius of curvature ranging from 6.13 to 9.00 mm. No statistically significant difference was found between the videokeratoscope and Orbscan systems in relation to accuracy or precision. The 95% confidence limits showed a close agreement between both instruments. The mean bias was less than ± 0.05 mm for both devices. The precision of the instruments was found to be similar. The EyeSys seems to measure more accurately, but the accuracy of the Orbscan was also acceptable, suggesting that both instruments are accurate and precise enough for research and clinical purposes. However, further studies of accuracy and repeatability of topographical measurements on human eyes generated by different topographers are necessary.

1 August 2012 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
JGJavier González-Pérez
Javier González-Pérez
CVCésar Villa-Collar
César Villa-Collar
JGJosé M. Gonzalez-Méijome
José M. Gonzalez-Méijome
NGNery Garcia-Porta
Nery Garcia-Porta
MPManuel Ángel Parafita
Manuel Ángel Parafita
Purpose. To monitor changes in corneal structure and level of inflammatory mediators in tears of myopic patients following orthokeratology (OK) and laser in situ keratomileusis (LASIK). Methods. Sixty-two myopic subjects were analyzed in this prospective study. Thirty-two had worn Paragon CRT contact lenses and 30 underwent standard LASIK. Thirty-two control subjects were also recruited. Pachometry and corneal topography were performed 12 months after both interventions. Tears were collected and assayed using ELISA for IL-6, IL-8, matrix metalloproteinase-9 (MMP-9), and epidermal growth factor (EGF). Results. Corneal power decreased in the central area and increased in the paracentral area. Simultaneously, there was a central corneal thinning with mid-peripheral thickening for OK. No changes were observed for LASIK. In comparison with controls, IL-6, IL-8, MMP-9, and EGF levels were increased significantly for OK (P < 0.01). Only MMP-9 (P < 0.01) and EGF (P < 0.01) were increased for LASIK. Pro-inflammatory response was found to be associated with the degree of myopia in the OK group. The MMP-9 and EGF upregulation was linked to the presence of iron deposition in both groups, whereas increased levels of EGF were connected with the presence of myopic regression after LASIK. Conclusions. Both interventions involved important tissue reshaping. The physical presence of a reverse geometry contact lens caused certain markers to change significantly in comparison with no lens wear or LASIK in the long-term response. MMP-9 was significantly higher in tears of subjects presenting iron deposition after OK or LASIK, and EGF levels seemed to play an important role in postoperative refractive outcomes after LASIK.

1 March 2011 in Eye & Contact Lens: Science & Clinical Practice
Verified
Journal Article
Closed access
JGJavier González-Pérez
Javier González-Pérez
JGJosé M. Gonzalez-Méijome
José M. Gonzalez-Méijome
MAMaría Teresa Rodríguez Ares
María Teresa Rodríguez Ares
MPManuel Ángel Parafita
Manuel Ángel Parafita
To evaluate the reliability of three noninvasive pachometry methods against the ultrasound pachometer considered the gold standard. Central corneal thickness (CCT) was measured using a Paxis ultrasound (US) pachometer, Orbscan II, Pentacam, and Topcon SP-3000 specular microscope in 22 right eyes of 22 healthy adults (7 men, 15 women). Three repeated measures were obtained and then compared to obtain the repeatability of each instrument and the agreement between pachometers. Pentacam is the optical system that renders values of CCT closer to those obtained with US pachometry. Conversely, a specular microscope shows a poorer agreement with US measures, and differences depend on the thickness being measured. The Orbscan system shows a consistent trend toward underestimation of CCT compared with US and Pentacam irrespective of the value measured. Different optical methods used to measure CCT showed significantly different results compared with US pachometry except for the Pentacam system. Clinicians should take into account the fact that specular microscopy might either underestimate or overestimate values of CCT, whereas Orbscan systematically overestimates CCT compared with US and Pentacam.

13 April 2018 in Current Eye Research
Verified
Journal Article
Closed access
JGJavier González-Pérez
Javier González-Pérez
JPJuan Queiruga Piñeiro
Juan Queiruga Piñeiro
ÁGÁngelx Sánchez García
Ángelx Sánchez García
JGJosé M. Gonzalez-Méijome
José M. Gonzalez-Méijome
Purpose: To compare central corneal thickness (CCT) measured by standard ultrasound pachymetry (USP), and three non-contact devices in healthy eyes. Methods: A cross-sectional study of CCT measurement in 52 eyes of 52 healthy volunteers was done by a single examiner at Ocular Surface and Contact Lens Laboratory. Three consecutive measurements were done by standard USP, non-contact tono-pachymeter, Pentacam corneal topographer, and Anterior Segment Optical Coherence Tomography (AS-OCT). The mean values were used for assessment. The results were compared using multivariate ANOVA, linear regression, and Pearson correlation. Agreement among the devices was analyzed using mean differences and Bland–Altman analysis with 95% limits of agreement (LoA). Finally, reliability was analyzed using intraclass correlation coefficient (ICC). Results: Mean CCT by ultrasound pachymeter, tono-pachymeter, corneal topographer and AS-OCT were 558.9 ± 31.2 µm, 525.8 ± 43.1 µm, 550.4 ± 30.5 µm, and 545.9 ± 30.5 µm respectively. There was a significant positive correlation between AS-OCT and USP (Pearson correlation = 0.957, p < 0.001), corneal topography and USP (Pearson correlation = 0.965, p < 0.001), and corneal topography and AS-OCT (Pearson correlation = 0.965, p < 0.001). There was a lower correlation between CT-1P tono-pachymeter and the other three modalities. Intraclass correlation coefficients show an excellent reliability between pairs except for CT-1P against the other three instruments that were found moderate. Conclusions: CT-1P tono-pachymeter underestimates CCT measurements compared to Scheimpflug system, AS-OCT device, and USP. Mean CCT among USP, Pentacam and AS-OCT were comparable and had significant linear correlations. In clinical practice, these three modalities could be interchangeable in healthy patients.

1 August 2004 in Archivos de la Sociedad Española de Oftalmología
Verified
Journal Article
Open access
EYE Yebra-Pimentel
E Yebra-Pimentel
JGJm González-Méijome
Jm González-Méijome
ACA Cerviño
A Cerviño
MGMj Giráldez
Mj Giráldez
JGJ González-Pérez
J González-Pérez
MPMa Parafita
Ma Parafita
To determine the relevance of the different ocular optical components in the refractive state of young adults, paying special attention to the corneal topography represented by the asphericity value. Corneal topographies and ultrasonic biometries were obtained from 109 university students with different refractive errors (spherical equivalent range: +3.25 D to -11.00 D). A regression study was performed in order to establish the relationships between corneal asphericity and refractive error, as well as other ocular optical components related to the emmetropization mechanism of the eye. The mean asphericity values were -0.23 (SD 0.08, range: -0.42 to -0.03). All the values correspond to the mathematical description of the prolate ellipse, most commonly accepted for the normal human cornea. The statistical correlation between asphericity and equivalent refractive error was not significant, but a significant correlation was found for the asphericity with respect to the radius of curvature, vitreous chamber depth and axial length. 1) The asphericity values support the generalised morphology of the prolate cornea as the standard. The influence of this configuration on the contact lens fit, refractive surgery or the visual performance of the eye are discussed. 2) Results suggest that, although a relationship between axial length and corneal topography actually exists, it is not likely that the latter has implications for the emmetropization mechanisms which determine the refractive state of the adult eye.