Clianta Yudin Kharismasari

Clianta Yudin Kharismasari

Auto-generated profile, based on publicly available information

Clianta Yudin Kharismasari

Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Padjadjaran, Bandung 45363, Indonesia

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2026 in Journal of Electrochemical Science and Engineering
Verified
Journal Article
Open access
PDF file
CKClianta Yudin Kharismasari
Clianta Yudin Kharismasari
Ari HardiantoAri Hardianto
Ari Hardianto
MZMuhammad Ihda Hamlu Liwaissunati Zein
Muhammad Ihda Hamlu Liwaissunati Zein
Salma Nur ZakiyyahSalma Nur Zakiyyah
Salma Nur Zakiyyah
YHYeni Wahyuni Hartati
Yeni Wahyuni Hartati
IIIrkham Irkham
Irkham Irkham
Screen-printed carbon electrodes (SPCEs) modified with cerium oxide (ceria) have attracted considerable attention due to their outstanding stability and electrochemical performance, making them promising candidates for sensor and biosensor applications. However, the anodic electrodeposition of ceria on SPCEs involves multiple parameters that may strongly influence film formation and electrochemical behaviour, yet these factors have not been systematically optimized. This study aimed to determine and optimize the key parameters affecting anodic electrodeposition of ceria on SPCEs using cyclic voltammetry (CV) and res­ponse surface methodology. All four main parameters, namely UV irradiation time, distance between the SPCE and UV lamp, cerium nitrate concentration and the number of CV cycles, significantly influence the anodic electrodeposition process of ceria, shown by the statistical analysis (p <0.05). The optimized SPCE/ceria electrode exhibited improved electrochemical performance, with an average peak current of 44.158 μA and a relative standard deviati-on (RSD) of 2.68 %. This optimized SPCE/ceria was subsequently tested for guanine oxide­tion using differential pulse voltammetry with an immobilized RNA probe and produced good repeatability with an RSD value of 2.37 %. The findings underscore the importance of parameter optimization to enhance the reproducibility and sensitivity of SPCE/ceria electrodes, demonstrating their strong potential for future biosensing applications.

27 October 2026 in ADMET and DMPK
Verified
Journal Article
Open access
PDF file
CKClianta Yudin Kharismasari
Clianta Yudin Kharismasari
Salma Nur ZakiyyahSalma Nur Zakiyyah
Salma Nur Zakiyyah
MZMuhammad Ihda Hamlu Liwaissunati Zein
Muhammad Ihda Hamlu Liwaissunati Zein
Ari HardiantoAri Hardianto
Ari Hardianto
Mara MirasoliMara Mirasoli
Mara Mirasoli
YHYeni Wahyuni Hartati
Yeni Wahyuni Hartati
Background and purpose: Chikungunya virus (CHIKV) remains a health concern because its symptoms overlap with dengue and Zika, often leading to misdiagnosis. Conventional diagnostic methods, including viral isolation, enzyme-linked immunosorbent assay (ELISA) and reverse transcription-polymerase chain reaction (RT-PCR), are time-consuming, costly, and dependent on specialized laboratories. This study aimed to develop a rapid, selective, and sensitive electrochemical biosensor integrated with CRISPR/Cas12 for CHIKV DNA detection. Experimental approach: A CHIKV-specific guide RNA targeting a conserved region of the E1 gene was designed in silico and selected by specificity score (99.15) and E-value (1.7). The platform used a gold particle-modified screen-printed carbon electrode (SPCE/Au) functionalized with a ferrocene-labelled DNA reporter. The electrode was characterized electrochemically, and the biosensor was tested for its response to CHIKV DNA, its selectivity against dengue virus (DENV) and SARS-CoV-2, and its detection performance across target concentrations. Key results: Au deposition enhanced the electrochemical properties of the electrode. Recognition of CHIKV DNA activated the CRISPR/Cas12 complex, whose collateral cleavage of the reporter reduced the ferrocene oxidation signal. The biosensor exhibited a concentration-dependent response over 0.01 to 10 ppb, with a limit of detection of 0.92 ppb and a limit of quantification of 2.77 ppb. The biosensor showed excellent selectivity against CHIKV competitors. Conclusion: This work shows that combining CRISPR/Cas12 collateral cleavage with a ferrocene-labelled reporter on SPCE/Au enables rapid, selective, and sensitive CHIKV detection. Validation with clinical samples is still needed. The platform supports early diagnosis and disease surveillance, in line with Sustainable Development Goal (SDG) 3 (Good Health and Well-being).