Muhammad Ihda Hamlu Liwaissunati Zein

Mr. Muhammad Ihda Hamlu Liwaissunati Zein

Padjadjaran University, Bandung, Jawa Barat, Indonesia
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
YHYeni Wahyuni Hartati
Yeni Wahyuni Hartati
IIIrkham Irkham
Irkham Irkham
ISIis Sumiati
Iis Sumiati
SWSanthy Wyantuti
Santhy Wyantuti
SGShabarni Gaffar
Shabarni Gaffar
MOMehmet Ozsoz
Mehmet Ozsoz
Fast, sensitive, and easy-to-use methods for detecting DNA related to food adulteration, health, religious, and commercial purposes are evolving. In this research, a label-free electrochemical DNA biosensor method was developed for the detection of pork in processed meat samples. Gold electrodeposited screen-printed carbon electrodes (SPCEs) were used and characterized using SEM and cyclic voltammetry. A biotinylated probe DNA sequence of the Cyt b S. scrofa gene mtDNA used as a sensing element containing guanine substituted by inosine bases. The detection of probe-target DNA hybridization on the streptavidin-modified gold SPCE surface was carried out by the peak guanine oxidation of the target using differential pulse voltammetry (DPV). The optimum experimental conditions of data processing using the Box–Behnken design were obtained after 90 min of streptavidin incubation time, at the DNA probe concentration of 1.0 µg/mL, and after 5 min of probe-target DNA hybridization. The detection limit was 0.135 µg/mL, with a linearity range of 0.5–1.5 µg/mL. The resulting current response indicated that this detection method was selective against 5% pork DNA in a mixture of meat samples. This electrochemical biosensor method can be developed into a portable point-of-care detection method for the presence of pork or food adulterations.

Verified
Journal Article
Open access
PDF file
Salma Nur ZakiyyahSalma Nur Zakiyyah
Salma Nur Zakiyyah
Abdullahi Umar IbrahimAbdullahi Umar Ibrahim
Abdullahi Umar Ibrahim
MAManal Salah babiker Ali
Manal Salah babiker Ali
SGShabarni Gaffar
Shabarni Gaffar
MOMehmet Ozsoz
Mehmet Ozsoz
YHYeni Wahyuni Hartati
Yeni Wahyuni Hartati
Tropical diseases (TDs) are among the leading cause of mortality and fatality globally. The emergence and reemergence of TDs continue to challenge healthcare system. Several tropical diseases such as yellow fever, tuberculosis, cholera, Ebola, HIV, rotavirus, dengue, and malaria outbreaks have led to endemics and epidemics around the world, resulting in millions of deaths. The increase in climate change, migration and urbanization, overcrowding, and other factors continue to increase the spread of TDs. More cases of TDs are recorded as a result of substandard health care systems and lack of access to clean water and food. Early diagnosis of these diseases is crucial for treatment and control. Despite the advancement and development of numerous diagnosis assays, the healthcare system is still hindered by many challenges which include low sensitivity, specificity, the need of trained pathologists, the use of chemicals and a lack of point of care (POC) diagnostic. In order to address these issues, scientists have adopted the use of CRISPR/Cas systems which are gene editing technologies that mimic bacterial immune pathways. Recent advances in CRISPR-based biotechnology have significantly expanded the development of biomolecular sensors for diagnosing diseases and understanding cellular signaling pathways. The CRISPR/Cas strategy plays an excellent role in the field of biosensors. The latest developments are evolving with the specific use of CRISPR, which aims for a fast and accurate sensor system. Thus, the aim of this review is to provide concise knowledge on TDs associated with mosquitoes in terms of pathology and epidemiology as well as background knowledge on CRISPR in prokaryotes and eukaryotes. Moreover, the study overviews the application of the CRISPR/Cas system for detection of TDs associated with mosquitoes.

17 June 2025 in ADMET and DMPK
Verified
Journal Article
Open access
PDF file
DWDika Apriliana Wulandari
Dika Apriliana Wulandari
MZMuhammad Ihda Hamlu Liwaissunati Zein
Muhammad Ihda Hamlu Liwaissunati Zein
Salma Nur ZakiyyahSalma Nur Zakiyyah
Salma Nur Zakiyyah
SISafri Ishmayana
Safri Ishmayana
MOMehmet Ozsoz
Mehmet Ozsoz
YHYeni Wahyuni Hartati
Yeni Wahyuni Hartati
Background and purpose: Multidrug-resistant tuberculosis (MDR-TB) remains a significant challenge in tuberculosis (TB) treatment, driven by simultaneous mutations in the rpoB and katG genes that confer resistance to rifampicin and isoniazid. While many molecular diagnostic tools focus on rpoB, the katG gene is often overlooked despite its critical role in confirming MDR-TB. This study aims to develop a CRISPR/Cas9-based electrochemical biosensor for the rapid and selective detection of katG mutation. Experimental approach: A guide RNA (gRNA) specific to the mutation site on katG gene was designed using the Benchling CRISPR tool, considering on-target and off-target scores, specificity, and cleavage sites within the Mycobacterium tuberculosis genome. The selected gRNA achieved the highest on-target score of 61.2 and an off-target score of 49.0 at cut position 2928, with a PAM sequence of AGG. Its cleavage efficiency was validated experimentally using an electrochemical biosensing platform incorporating a gold-modified screen-printed carbon electrode (SPCE/Au). Redox response enhancement by [Fe(CN6)]3-/4- confirmed the improved performance of the electrode. Key results: The biosensor system detects the target DNA through hybridization with DNA probe-Fc, forming double-stranded DNA (dsDNA) that is recognized and cleaved by the Cas9/gRNA complex. This cleavage significantly reduces the ferrocene oxidation signal, indicating the presence of a katG mutation. Non-mutated target DNA produces a nondetectable ferrocene signal, suggesting that the Cas9 enzyme may remain bound to the electrode without cleavage. The CRISPR/Cas9 electrochemical biosensor demonstrated a low detection limit of 7.5530 aM and a detection range of 101 to 106 aM. Conclusion: The CRISPR/Cas9-based electrochemical biosensor exhibits high sensitivity and specificity for the detection katG mutation, offering a promising platform for rapid MDR-TB diagnostics.

6 February 2026 in ACS Sensors
Verified
Journal Article
Closed access
Salma Nur ZakiyyahSalma Nur Zakiyyah
Salma Nur Zakiyyah
IIIrkham Irkham
Irkham Irkham
DWDika Apriliana Wulandari
Dika Apriliana Wulandari
MZMuhammad Ihda Hamlu Liwaissunati Zein
Muhammad Ihda Hamlu Liwaissunati Zein
SGShabarni Gaffar
Shabarni Gaffar
YHYeni Wahyuni Hartati
Yeni Wahyuni Hartati

9 June 2025 in Journal of Electrochemical Science and Engineering
Verified
Journal Article
Open access
PDF file
IIIrkham Irkham
Irkham Irkham
FAFadli Taufik Abdillah
Fadli Taufik Abdillah
MZMuhammad Ihda Hamlu Liwaissunati Zein
Muhammad Ihda Hamlu Liwaissunati Zein
ADAdisyahputra
Adisyahputra
NZNazwa Alya Zahra
Nazwa Alya Zahra
YHYeni Wahyuni Hartati
Yeni Wahyuni Hartati
Porcine gelatin is widely used in the food and pharmaceutical industries due to its favorable functional properties and low cost. However, its presence in consumer products raises serious concerns for individuals with dietary restrictions based on religious, ethical, or health considerations. In this study, a label-free electrochemical immunosensor was developed using a boron-doped diamond electrode modified with aryl diazonium salt for the selective and sensitive detection of porcine gelatin. The diazonium electrografting enabled stable covalent immobilization of anti-porcine gelatin antibodies via protein A, preserving anti­body orientation and activity. Experimental parameters were optimized using the Box-Behnken design, yielding ideal conditions of 500× antibody concentration, 60 min antibody incubation, and 15 min gelatin incubation. Detection was performed using differential pulse voltammetry with [Fe(CN)₆]3-/4- as a redox probe, allowing label-free monitoring of anti­body-antigen interactions based on changes in current. The immunosensor demonstrated excellent analytical performance, with a detection limit of 142.15 pg mL-1. Specificity testing confirmed that the sensor responds exclusively to porcine gelatin, showing no cross-reactivity with bovine gelatin. These results demonstrate that the proposed immunosensor provides a rapid, highly sensitive, and specific platform for porcine gelatin detection, offering great potential for food authentication and halal verification.

30 March 2026 in Journal of Electrochemical Science and Engineering
Verified
Journal Article
Open access
PDF file
CKClianta Yudin Kharismasari
Clianta Yudin Kharismasari
Ari HardiantoAri Hardianto
Ari Hardianto
MZMuhammad Ihda Hamlu Liwaissunati Zein
Muhammad Ihda Hamlu Liwaissunati Zein
Salma Nur ZakiyyahSalma Nur Zakiyyah
Salma Nur Zakiyyah
YHYeni Wahyuni Hartati
Yeni Wahyuni Hartati
IIIrkham Irkham
Irkham Irkham
Screen-printed carbon electrodes (SPCEs) modified with cerium oxide (ceria) have attracted considerable attention due to their outstanding stability and electrochemical performance, making them promising candidates for sensor and biosensor applications. However, the anodic electrodeposition of ceria on SPCEs involves multiple parameters that may strongly influence film formation and electrochemical behaviour, yet these factors have not been systematically optimized. This study aimed to determine and optimize the key parameters affecting anodic electrodeposition of ceria on SPCEs using cyclic voltammetry (CV) and res­ponse surface methodology. All four main parameters, namely UV irradiation time, distance between the SPCE and UV lamp, cerium nitrate concentration and the number of CV cycles, significantly influence the anodic electrodeposition process of ceria, shown by the statistical analysis (p <0.05). The optimized SPCE/ceria electrode exhibited improved electrochemical performance, with an average peak current of 44.158 μA and a relative standard deviati-on (RSD) of 2.68 %. This optimized SPCE/ceria was subsequently tested for guanine oxide­tion using differential pulse voltammetry with an immobilized RNA probe and produced good repeatability with an RSD value of 2.37 %. The findings underscore the importance of parameter optimization to enhance the reproducibility and sensitivity of SPCE/ceria electrodes, demonstrating their strong potential for future biosensing applications.