Photonics Technology Laboratory, National Electronics and Computer Technology Center (NECTEC), National Science and Technology Development Agency (NSTDA), 112 Thailand Science Park, Pahol Yothin Rd., Klong Luang, Pathumthani 12120, Thailand
Auto-generated profile, based on publicly available information
Ratthasart Amarit
Photonics Technology Laboratory, National Electronics and Computer Technology Center (NECTEC), National Science and Technology Development Agency (NSTDA), 112 Thailand Science Park, Pahol Yothin Rd., Klong Luang, Pathumthani 12120, Thailand
Recent developments in smartphone-based strip readers have further improved the performances of lateral flow test kits. Most smartphone cameras encode an unaltered and nonlinear power-law transfer function that maps the light intensity to a pixel value; this poses some limitations for camera-based strip readers. For faint-color test lines which are almost as white such as with nitrocellulose pads, the slope of the transfer function is low. Therefore, it is difficult to differentiate between the faint test lines and the white background. We show that by manually setting the camera exposure time—instead of using the automatic settings—to the high-slope region of the transfer function, the reader’s sensitivity can be improved. We found that the sensitivity and the limit of detection of the Acidovorax avenae subsp. citrulli (Aac) test kit were enhanced up to 3-fold and 5-fold, respectively, when using the readers at the optimal camera settings, compared to the automatic mode settings. This simple technique can be readily applied to any existing camera-based colorimetric strip reader to significantly improve its performance.
In this study, readily available antibodies that are used in standard agglutination tests were evaluated for their use in ABO blood typing by a surface plasmon resonance imaging (SPR imaging) technique. Five groups of antibodies, including mixed clones of anti-A, anti-B, and anti-AB, and single clones of anti-A and anti-B, were used to construct the five-line detection arrays using a multichannel flow cell in the SPR imager. The red blood cell (RBC) samples were applied to a multichannel flow cell that was orthogonal to the detection line arrays for blood group typing. We found that the blood samples were correctly grouped in less than 12 min by the SPR imaging technique, and the results were consistent with those of the standard agglutination technique for all 60 samples. We found that mixed clones of antibodies provided 33%–68% greater change in the SPR signal than the single-clone antibodies. Applying the SPR imaging technique using readily available antibodies may reduce the costs of the antibodies, shorten the measurement time, and increase the throughput.
Random numbers are important in many activities, including communication, encryption, science, gambling, finance, and decision making. There is a strong demand for a hardware random number generator that could support cryptographic applications. In this work, we propose a quantum tunneling diode as a source of true randomness achieved by applying electrical current sweeps through the device and then harnessing a time-counting unit to measure fluctuation of current flows. Our approach can be implemented with inexpensive electronics and could be integrated into systems that require random numbers such as portable communication devices.
We demonstrate quantum random number generation based on a photon-number detection scheme with the use of a silicon photomultiplier. We implement a time integral with detector response signals for resolving photon numbers, which are subsequently digitized into a stream of 4-bit sequences with a generation rate of 13.6 Mbit/s. Our generated random bits pass the statistical randomness validation according to the U.S. National Institute of Standards and Technology (NIST) Special Publication 800-22. This scheme is implementable with inexpensive components, and the system can be miniaturized to the size of a plug-and-play portable cryptographic device.
As fast human temperature screening is needed in large public areas, this paper proposes a low-cost mobile platform module that combines the advantages of analyzing visible and thermal images. In particular, the key idea relies on face detection in the visible image. Then the coordinates of all faces detected are mapped on to the thermal image to determine their corresponding temperatures. Internal temperature compensation and external reference temperature also are employed to reduce the unwanted temperature fluctuation inside the module and in the surrounding environment. Our mobile platform module, called $\unicode{x00B5} {\rm Therm}$, uses a FLIR ONE camera as our visible and thermal imaging cameras. It can simultaneously determine the temperatures of nine people at a speed of 8 frames/second. A field test operation was performed for four days with 1,170 people, with very promising results of 100% sensitivity, 92.6% specificity, and 92.7% accuracy.