10 September 2025 in Magnetic Resonance in Medicine
Purpose: To develop and evaluate a volumetric proton resonance frequency shift (PRF)–based thermometry method for monitoring thermal ablation in moving tissues. Methods: A golden‐angle‐ordered 3D stack‐of‐radial MRI sequence was combined with an image‐navigated multi‐baseline (iNAV‐MB) PRF method to reconstruct motion‐compensated 3D temperature maps with high spatiotemporal resolution and volumetric coverage. Two radial MRI reconstruction techniques, k‐space weighted image contrast filter (KWIC) and golden‐angle radial sparse parallel (GRASP) MRI, were implemented and compared within a sliding window reconstruction framework. Ex vivo motion phantom experiments were performed with high‐intensity focused ultrasound ablation to evaluate motion tracking and temperature accuracy using input motion waveforms and temperature probe readings as references. In vivo non‐heating swine experiments were conducted to assess temperature mapping stability in 3D liver regions of interest. Results: The proposed iNAV‐MB thermometry framework achieved volumetric coverage of 24 axial slices (3‐mm thickness), in‐plane resolution of 1.6 × 1.6 to 1.8 × 1.8 mm 2 , and effective temporal resolution of 0.98 s/volume. In ex vivo high‐intensity focused ultrasound experiments, motion tracking achieved correlation coefficients of 0.951 and 0.973, and temporal mean absolute errors were 1.80°C and 1.44°C using KWIC and GRASP, respectively. In vivo experiments demonstrated improvements in voxel‐wise temperature temporal SD from a median of 8.03 to 3.85°C (KWIC) and from a median of 7.23 to 2.37°C (GRASP), compared to single‐baseline PRF. Conclusion: The proposed stack‐of‐radial iNAV‐MB volumetric PRF thermometry framework can reliably track respiratory motion and map ablation‐associated temperature change. This framework has the potential to improve MRI‐guided thermal ablation in moving tissues.
1 June 2026 in Magnetic Resonance in Medicine
Purpose: To develop a software‐based active electromagnetic interference (EMI) suppression (AES) framework on whole‐body multi‐channel MRI systems for reliable MRI and MR thermometry during MRI‐guided microwave ablation (MWA). Methods: In addition to primary imaging coils, an unloaded standard body array coil was positioned outside the imaging volume to serve as “auxiliary coils” for detecting and characterizing EMI. At each time frame, principal component analysis compressed the auxiliary coil data to extract the dominant EMI pattern. The EMI coupled into the primary coils was then modeled with channel‐specific impulse response functions and subtracted from the primary coil data on a frame‐by‐frame basis. The framework was evaluated through MWA experiments in gel phantoms and in vivo pig models at 3 T with parallel imaging acceleration. Proton resonance frequency shift (PRF) MR thermometry accuracy was assessed using fiber‐optic probes. The PRF‐derived thermal dose prediction was compared with post‐ablation MRI and tissue gross pathology. Results: AES effectively suppressed EMI‐induced artifacts and substantially improved image quality, yielding signal‐to‐noise ratio enhancement of 40‐fold (gel) and 13‐fold (in vivo) and an EMI suppression rate > 92%. Reliable PRF temperature mapping was enabled, with temporal mean‐absolute‐error of < 1.4°C and < 0.3°C in ablated and non‐heating regions, respectively. Thermal dose estimation matched post‐ablation MRI and gross pathology findings. Conclusion: The proposed AES framework effectively suppressed ablation‐device‐related EMI and enabled reliable MRI and MR thermometry during MWA. This approach can be integrated into existing reconstruction pipelines to facilitate the broader clinical adoption of MRI‐guided MWA and other interventions affected by EMI.