1 July 2025 in Journal of Biomedical Optics
SignificanceCholesteatomas, benign tumors that grow in the middle ear, can lead to conductive hearing loss. If not completely removed during surgery, these tumors may regrow. Current imaging technologies struggle to detect residual tumors noninvasively due to limitations in contrast and resolution, often necessitating additional surgery for inspection. To address this, we developed a catheter endoscope capable of being inserted through the Eustachian tube, allowing detailed examination of the middle ear without surgery. Using two-photon polymerization (2PP) technology, we fabricated miniature, side-viewing reflective endoscope objectives. This approach enabled the rapid production of single-element objectives with highly repeatable optical properties, easily adaptable to specific imaging needs.AimWe aim to design, fabricate, and demonstrate a catheter endoscope for optical coherence tomography (OCT) endoscopy of the middle ear via the Eustachian tube.ApproachSide-viewing, reflective lenses were designed in OpticStudio and 3D printed using 2PP followed by sputter coating with gold. Standard metrology techniques were used to verify and optimize the objective’s shape. The optical performance of the catheter endoscopes was measured with a beam profiler. Finally, OCT imaging of the middle ear of a pig via the Eustachian tube was completed using the fully assembled catheter endoscope.ResultsMetrology showed the printed lenses conformed closely to the design. The catheter endoscope’s FWHM spot size had a mean ± standard deviation of 25.3±1.8 μm with a measured working distance of 1.960±0.057 mm. Volumetric OCT images of the middle ear, inner ear, and Eustachian tube were captured in a postmortem pig head using the catheter endoscope.ConclusionsThe 2PP approach is fast and highly repeatable for miniature reflective objective fabrication. OCT catheter endoscopy via the Eustachian tube enabled imaging of the middle ear, Eustachian tube, and surprisingly part of the inner ear.
4 December 2025 in Biomedical Optics Express
We present a fully 3D-printed, broadband endomicroscopic objective optimized for near-infrared two-photon fluorescence imaging, featuring a compact, alignment-free design. The objective provides a numerical aperture of 0.6 in water immersion over a 200 µm field of view and maintains near diffraction-limited performance across the 720–950 nm excitation band. Monolithically fabricated with multi-material via two-photon polymerization (2PP), the three-element refractive objective achieves a 2 mm lens mechanical diameter, a mechanical housing diameter of 3 mm, and a total length of 2.1 mm with an approximately 10-hour build time. A self-aligning architecture integrates the printed half-housing with the optics to minimize assembly error, yielding sub-10 µm element decenter and <0.1° element tilt. Optical performance was validated using a resolution target and biological specimens, with broadband excitation behavior assessed by two-photon imaging of pollen grains across multiple excitation wavelengths, and with autofluorescence imaging of fresh mouse liver confirming feasibility for in situ tissue imaging. This work demonstrates the potential of fully printed broadband objectives for compact, high-performance endomicroscopy and integrated biomedical optics.
1 March 2026 in Journal of Biomedical Optics
SignificanceThe three-dimensional (3D)-printed refractive rod objective for endoscopy preserves the compact, gradient index (GRIN)-like format while delivering a wide field of view (FOV) comparable to its diameter and larger than that of a commercial GRIN lens.AimWe focus on the design, fabrication, and experimental validation of a proof-of-concept refractive rod objective for fluorescence imaging of mouse colon tissue, with performance compared with a commercial GRIN lens.ApproachA 1× magnification refractive rod-like objective was designed in Zemax OpticStudio and fabricated using two-photon polymerization additive manufacturing. The objective consists of a sequence of convex refractive surfaces printed in contact at their vertices, with refractive index contrast provided by partially or non-polymerized resin contained within an enclosing wall. The lens has a diameter of 500 μm with a clear aperture of 470 μm, a total length of 2.06 mm, and a working distance of 1.6 mm and was optimized for a numerical aperture of 0.075 and a 500-μm design field at 525-nm light. Three photopolymer resins (IP-S, IP-Visio, and IPX-Clear) were evaluated through excitation–emission matrix measurements to assess autofluorescence. By imaging group 7, element 6 of a 1951 United States Air Force (USAF) resolution target, the field was assessed by plot profile and modulation transfer function measurements.ResultsThe fabricated objective resolved group 7, element 6 of a USAF resolution target (4.38 μm), closely matching the theoretical diffraction-limited resolution of 4.27 μm. Compared with a commercial 600-μm-diameter GRIN lens, the 3D-printed objective achieved a substantially larger FOV (498 versus 188 μm). Spectral characterization showed that IP-Visio exhibited the lowest autofluorescence under 455-nm excitation when unpolymerized resin was present. Using an IP-Visio objective, fluorescence images of proflavine-stained mouse colon tissue were successfully acquired.ConclusionsThe demonstrated refractive rod-like objective combines the compact geometry of a GRIN lens with the aberration correction capability of multi-element refractive optics, enabling uniform resolution across a large FOV. The approach also allows material selection tailored to fluorescence imaging requirements. Future work will focus on integration with fiber bundles and on fully polymerized designs with spatially tuned refractive index for improved long-term stability.
15 January 2026 in bioRxiv
In vivo microscopy (IVM) has shown great promise to improve early detection of epithelial precancer, but it suffers from fundamental trade-offs that limit the resolution, field-of-view (FOV) and depth-of-field (DOF). Here, we present PrecisionView, a compact, deep-learning-enabled endomicroscope that breaks these constrains and achieves 20 mm 2 FOV and 500 µm DOF with 4 µm resolution, representing approximately 5× increase in FOV and 8× larger DOF compared to conventional IVM with similar resolution. PrecisionView integrates a deep-learning optimized phase mask and real-time reconstruction, enabling rapid in vivo assessment of two key hallmarks of cancer: epithelial cell nuclear morphology and subsurface microvasculature through fluorescence and reflectance imaging. By imaging oral cavity of healthy volunteers and cervical specimens with precancerous lesions, PrecisionView generates large-scale (1-3 cm 2 ) co-registered maps of cellular and vascular structures, revealing distinct microscopic patterns associated with anatomic structures and precancerous lesions. Our results suggest the potential of this computational endomicroscope to address the unmet need for early cancer detection at the point-of-care.
12 December 2025 in Applied Optics
We report a hybrid miniaturized achromatic objective for nonlinear endomicroscopy that combines two-photon polymerization (2PP)-fabricated polymer optics with a commercial glass lens. The objective achieves 0.6 numerical aperture with dual-wavelength correction at 775 and 860 nm and a 200 µm field of view, all within a 3 mm housing compatible with a hypodermic tube. Fabrication leverages sequential multi-step two-photon polymerization (2PP) to produce a monolithic multi-material triplet with submicron precision. The triplet incorporates two photoresists with different dispersion properties printed in successive steps with post-processing and marker-based realignment between steps, yielding a single monolithic optic that eliminates adhesives while correcting chromatic aberrations. Imaging tests with USAF resolution targets, biological samples, and two-photon fluorescence microscopy of pollen grains demonstrate near-diffraction-limited performance across the design wavelength range. The approach offers a practical method for compact optical systems in biomedical applications.