Kohsuke Teranishi

Kohsuke Teranishi

Auto-generated profile, based on publicly available information

Kohsuke Teranishi

Naval Medical Research Center

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2008 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
FAFrançoise Arnaud
Françoise Arnaud
TTToshiki Tomori
Toshiki Tomori
WCWalter Carr
Walter Carr
AMAnne McKeague
Anne McKeague
KTKohsuke Teranishi
Kohsuke Teranishi
RMRichard McCarron
Richard McCarron

1 January 2010 in Blood Coagulation & Fibrinolysis
Verified
Journal Article
Closed access
TTToshiki Tomori
Toshiki Tomori
DHDaniel Hupalo
Daniel Hupalo
KTKohsuke Teranishi
Kohsuke Teranishi
SMSarah Michaud
Sarah Michaud
MHMike Hammett
Mike Hammett
FAFrançoise Arnaud
Françoise Arnaud
Thromboelastography (TEG) or rotational thromboelastometry (ROTEM) assesses blood viscoelastic properties and clotting kinetics that can be measured by Haemoscope TEG and Pentapharm ROTEM devices using slightly different methodologies. These devices were compared by measuring blood samples associated with various degrees of coagulopathy. Blood samples, collected from swine undergoing three types of severe injury and resuscitation protocol resulting in normal, hypercoagulopathy, and hypocoagulopathy, were assessed with TEG or ROTEM before the surgical procedures, and after injury, fluid resuscitation, and simulated hospital phase. Standard clotting parameters were compared by Student's t-test at a significance of a P value less than 0.05. Regression analysis indicated a positive correlation between TEG and ROTEM for reaction time (R), clotting rate (K), and maximum amplitude (Ma) parameters. With samples of normal coagulation, R (440 +/- 136 vs. 391 +/- 73 s), K (99 +/- 39 vs. 81 +/- 20 s), and Ma (74 +/- 4 vs. 69 +/- 5 mm) were higher, whereas (alpha) (68 +/- 8 vs. 75 +/- 3 mm) was lower with TEG than ROTEM, respectively; a P value is less than 0.05. The magnitude of changes from baseline in hypercoagulable or hypocoagulable samples due to level of injury was equivalent with TEG and ROTEM indicating comparable use of the instruments. However, when samples were extremely hypocoagulopathic due to resuscitation fluid, the TEG values could not be readily determined. Overall, TEG readings were higher than ROTEM readings; this disparity between the two instruments was attenuated with hypercoaguable samples. Both devices yielded similar information regarding the status of coagulation related to trauma. Because of operating characteristics, the same instrument should be used for monitoring the same patient or study.