20 August 2008 in Annals of Biomedical Engineering
1 September 2009 in Journal of Vascular Surgery
1 October 2009 in Journal of Trauma: Injury, Infection & Critical Care
Major improvements have been made in the development of novel dressings with hemostatic properties to control heavy bleeding in noncompressible areas. To test the relative efficacy of different formulations in bleeding control, recently manufactured products need to be compared using a severe injury model. Ten hemostatic dressings and the standard gauze bandage were tested in anesthetized Yorkshire pigs hemorrhaged by full transection of the femoral vasculature at the level of the groin. Application of these dressings with a 5-minute compression period (at approximately 200 mm Hg) was followed with a subsequent infusion of colloid for a period of 30 minutes. Primary outcomes were survival and amount and incidence of bleeding after dressing application. Vital signs and wound temperature were continuously recorded throughout the 3-hour experimental observation. These findings indicated that four dressings were effective in improving bleeding control and superior to the standard gauze bandage. This also correlated with increased survival rates. Absorbent property, flexibility, and the hemostatic agent itself were identified as the critical factors in controlling bleeding on a noncompressible transected vascular and tissue injury. Celox, QuikClot ACS, WoundStat, and X-Sponge ranked superior in terms of low incidence of rebleeding, volume of blood loss, maintenance of mean arterial pressure >40 mm Hg, and survival.
1 July 2011 in Journal of Surgical Research
1 January 2010 in Blood Coagulation & Fibrinolysis
Thromboelastography (TEG) or rotational thromboelastometry (ROTEM) assesses blood viscoelastic properties and clotting kinetics that can be measured by Haemoscope TEG and Pentapharm ROTEM devices using slightly different methodologies. These devices were compared by measuring blood samples associated with various degrees of coagulopathy. Blood samples, collected from swine undergoing three types of severe injury and resuscitation protocol resulting in normal, hypercoagulopathy, and hypocoagulopathy, were assessed with TEG or ROTEM before the surgical procedures, and after injury, fluid resuscitation, and simulated hospital phase. Standard clotting parameters were compared by Student's t-test at a significance of a P value less than 0.05. Regression analysis indicated a positive correlation between TEG and ROTEM for reaction time (R), clotting rate (K), and maximum amplitude (Ma) parameters. With samples of normal coagulation, R (440 +/- 136 vs. 391 +/- 73 s), K (99 +/- 39 vs. 81 +/- 20 s), and Ma (74 +/- 4 vs. 69 +/- 5 mm) were higher, whereas (alpha) (68 +/- 8 vs. 75 +/- 3 mm) was lower with TEG than ROTEM, respectively; a P value is less than 0.05. The magnitude of changes from baseline in hypercoagulable or hypocoagulable samples due to level of injury was equivalent with TEG and ROTEM indicating comparable use of the instruments. However, when samples were extremely hypocoagulopathic due to resuscitation fluid, the TEG values could not be readily determined. Overall, TEG readings were higher than ROTEM readings; this disparity between the two instruments was attenuated with hypercoaguable samples. Both devices yielded similar information regarding the status of coagulation related to trauma. Because of operating characteristics, the same instrument should be used for monitoring the same patient or study.
1 August 2012 in Resuscitation