19 October 2013 in Journal of Intelligent & Robotic Systems
31 December 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Recovery of the upper extremity (UE) and hand function is considered the highest priority for people with tetraplegia, because these functions closely integrate with their activities of daily living. Spinal cord transcutaneous stimulation (scTS) has great potential to facilitate functional restoration of paralyzed limbs by neuro-modulating the excitability of the spinal network. Recently, this approach has been demonstrated effective in improving UE function in people with motor complete and incomplete cervical SCI. However, the research thus far is limited by the lack of a comprehensive assessment of functional improvement and neurological recovery throughout the intervention. The goal of this study was to investigate whether scTS can also facilitate UE functional restoration in an individual with motor and sensory complete tetraplegia. A 38-year-old male with a C5 level, ASIA Impairment Scale-A SCI (15 years post-injury, left hand dominant pre- and post-injury), received 18 sessions (60 minutes/session) of scTS combined with task-specific hand training over the course of 8 weeks. The total score of the Graded Redefined Assessment of Strength, Sensibility, and Prehension significantly improved from 72/232 to 96/232 at post-intervention, and maintained ranging from 82/232 to 86/232 during the three months follow-up without any further treatment. The bilateral handgrip force improved by 283.4% (left) and 30.7% (right), respectively at post-intervention. These strength gains were sustained at 233.5% -250% (left) and 11.5% -73.1% (right) during the follow-up evaluation visits. Neuromuscular Recovery Scale demonstrated dramatic and long-lasting improvements following the completion of the intervention. Changes of spinal motor evoked potentials from pre- to post-intervention indicated an increased level of spinal network excitability. The present data offer preliminary evidence that the novel scTS intervention combined with hand training can enhance UE functional use in people with motor and sensory complete SCI.
18 March 2019 in IEEE Transactions on Human-Machine Systems
The goal of this study was to investigate the use of cognitive modeling to assess the usability of an upper-limb prosthesis with a focus on mental workload responses. Prior studies have investigated usability of upper-limb prostheses with subjective surveys and physiological measures. However, these approaches have limitations, including subject recall of conditions and physiological response contamination by head and body movements and user speech during task performance as well as sensitivity to physical fatigue and room lighting conditions. Cognitive modeling was used to assess mental workload in use of transradial upper-limb prosthesis. A case study was conducted with a participant with upper-limb amputation using two different types of electromyography-based control schemes, including conventional direct control (DC) and pattern recognition (PR) control in order to compare cognitive model outcomes with mental workload assessment using eye-tracking measures. Cognitive models time estimates were also compared with actual task completion time results from the case study to further assess the validity of cognitive modeling as an analytical tool for evaluating upper limb prosthesis usability. Findings of both the cognitive models and case study revealed the PR mode to be more intuitive, reduce cognitive load, and increase efficiency in prosthetic control as compared to the DC mode. Results of the present study revealed that cognitive modeling can be used as an analytical approach for assessing upper-limb prosthetic device usability in terms of workload outcomes. Future studies should validate the present findings with more precise time estimations and a larger user sample size.