Fan Zhang

Fan Zhang

Auto-generated profile, based on publicly available information

Fan Zhang

Kessler Foundation, West Orange, NJ 07052 USA, and Department of Physical Medicine & Rehabilitation, Rutgers, New Jersey Medical School, Newark, NJ 07103, USA

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2013 in Journal of Intelligent & Robotic Systems
Verified
Journal Article
Closed access
PDF file
MLMing Liu
Ming Liu
FZFan Zhang
Fan Zhang
PDPhilip Datseris
Philip Datseris
HHHe (Helen) Huang
He (Helen) Huang

4 September 2017 in Sensors
Verified
Journal Article
Open access
PDF file
MLMing Liu
Ming Liu
FZFan Zhang
Fan Zhang
HHHe (Helen) Huang
He (Helen) Huang
Algorithms for locomotion mode recognition (LMR) based on surface electromyography and mechanical sensors have recently been developed and could be used for the neural control of powered prosthetic legs. However, the variations in input signals, caused by physical changes at the sensor interface and human physiological changes, may threaten the reliability of these algorithms. This study aimed to investigate the effectiveness of applying adaptive pattern classifiers for LMR. Three adaptive classifiers, i.e., entropy-based adaptation (EBA), LearnIng From Testing data (LIFT), and Transductive Support Vector Machine (TSVM), were compared and offline evaluated using data collected from two able-bodied subjects and one transfemoral amputee. The offline analysis indicated that the adaptive classifier could effectively maintain or restore the performance of the LMR algorithm when gradual signal variations occurred. EBA and LIFT were recommended because of their better performance and higher computational efficiency. Finally, the EBA was implemented for real-time human-in-the-loop prosthesis control. The online evaluation showed that the applied EBA effectively adapted to changes in input signals across sessions and yielded more reliable prosthesis control over time, compared with the LMR without adaptation. The developed novel adaptive strategy may further enhance the reliability of neurally-controlled prosthetic legs.

31 December 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
FZFan Zhang
Fan Zhang
KMKamyar Momeni
Kamyar Momeni
ARArvind Ramanujam
Arvind Ramanujam
MRManikandan Ravi
Manikandan Ravi
JCJanelle Carnahan
Janelle Carnahan
GFGail F. Forrest
Gail F. Forrest
Recovery of the upper extremity (UE) and hand function is considered the highest priority for people with tetraplegia, because these functions closely integrate with their activities of daily living. Spinal cord transcutaneous stimulation (scTS) has great potential to facilitate functional restoration of paralyzed limbs by neuro-modulating the excitability of the spinal network. Recently, this approach has been demonstrated effective in improving UE function in people with motor complete and incomplete cervical SCI. However, the research thus far is limited by the lack of a comprehensive assessment of functional improvement and neurological recovery throughout the intervention. The goal of this study was to investigate whether scTS can also facilitate UE functional restoration in an individual with motor and sensory complete tetraplegia. A 38-year-old male with a C5 level, ASIA Impairment Scale-A SCI (15 years post-injury, left hand dominant pre- and post-injury), received 18 sessions (60 minutes/session) of scTS combined with task-specific hand training over the course of 8 weeks. The total score of the Graded Redefined Assessment of Strength, Sensibility, and Prehension significantly improved from 72/232 to 96/232 at post-intervention, and maintained ranging from 82/232 to 86/232 during the three months follow-up without any further treatment. The bilateral handgrip force improved by 283.4% (left) and 30.7% (right), respectively at post-intervention. These strength gains were sustained at 233.5% -250% (left) and 11.5% -73.1% (right) during the follow-up evaluation visits. Neuromuscular Recovery Scale demonstrated dramatic and long-lasting improvements following the completion of the intervention. Changes of spinal motor evoked potentials from pre- to post-intervention indicated an increased level of spinal network excitability. The present data offer preliminary evidence that the novel scTS intervention combined with hand training can enhance UE functional use in people with motor and sensory complete SCI.

21 July 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
FZFan Zhang
Fan Zhang
MLMing Liu
Ming Liu
HHHe Huang
He Huang
Current powered prosthetic legs require switching control modes according to the task the user is performing (e.g. level-ground walking, stair climbing, walking on slopes, etc.). To allow prosthesis users safely and seamlessly transition between tasks, it is critical to determine when to switch the prosthesis control mode during task transitions. Our previous study defined critical timings for different types of task transitions in ambulation; however, it is unknown whether it is the unique timing that allows safe and seamless transitions. The goals of this study were to (1) systematically investigate the effects of mode switch timing on the prosthesis user’s performance in task transitions, and (2) identify appropriate timing to switch the prosthesis control mode so that the users can seamlessly transition between different locomotion tasks. Five able-bodied (AB) and two transfemoral (TF) amputee subjects were tested as they wore a powered knee prosthesis. The prosthesis control mode was switched manually at various times while the subjects performed different types of task transitions. The subjects’ task transition performances were evaluated by their walking balance and success in performing seamless task transitions. The results demonstrated that there existed a time window within which switching the prosthesis control mode neither interrupted the subjects’ task transitions nor disturbed their walking balance. Therefore, the results suggested the control mode switching of a lower limb prosthesis can be triggered within an appropriate time window instead of a specific timing or an individual phase. In addition, a generalized criterion to determine the appropriate mode switch timing was proposed. The outcomes of this study could provide important guidance for future designs of neurally controlled powered knee prostheses that are safe and reliable to use.

18 March 2019 in IEEE Transactions on Human-Machine Systems
Verified
Journal Article
Closed access
MZMaryam Zahabi
Maryam Zahabi
MWMelissa Mae White
Melissa Mae White
WZWenjuan Zhang
Wenjuan Zhang
AWAnna T. Winslow
Anna T. Winslow
FZFan Zhang
Fan Zhang
DKDavid B. Kaber
David B. Kaber
The goal of this study was to investigate the use of cognitive modeling to assess the usability of an upper-limb prosthesis with a focus on mental workload responses. Prior studies have investigated usability of upper-limb prostheses with subjective surveys and physiological measures. However, these approaches have limitations, including subject recall of conditions and physiological response contamination by head and body movements and user speech during task performance as well as sensitivity to physical fatigue and room lighting conditions. Cognitive modeling was used to assess mental workload in use of transradial upper-limb prosthesis. A case study was conducted with a participant with upper-limb amputation using two different types of electromyography-based control schemes, including conventional direct control (DC) and pattern recognition (PR) control in order to compare cognitive model outcomes with mental workload assessment using eye-tracking measures. Cognitive models time estimates were also compared with actual task completion time results from the case study to further assess the validity of cognitive modeling as an analytical tool for evaluating upper limb prosthesis usability. Findings of both the cognitive models and case study revealed the PR mode to be more intuitive, reduce cognitive load, and increase efficiency in prosthetic control as compared to the DC mode. Results of the present study revealed that cognitive modeling can be used as an analytical approach for assessing upper-limb prosthetic device usability in terms of workload outcomes. Future studies should validate the present findings with more precise time estimations and a larger user sample size.