7 May 2025 in Nature Cardiovascular Research
1 March 2025 in Applied Physics Letters
Fourier ptychography (FP) is widely adopted for label-free, high-resolution quantitative phase imaging (QPI) of biological samples. However, its imaging speed is limited by the need for multiple acquisitions. In this work, we propose a single-shot FP technique that uses linear polarizers to encode multiple illumination wavevectors and a polarization camera to capture multiple sets of information simultaneously. A multiplexed FP algorithm, utilizing both the bright-field and dark-field information, reconstructs a high-resolution quantitative phase image from the single-shot intensity image. Verified with resolution targets and a histological sample, our method achieved a resolution improvement of 2.5 times the diffraction limit of the objective lens and provided QPI over a large field-of-view. Additionally, we demonstrated high-speed FP at 75 frames per second, limited only by the sensor's readout speed, enabling QPI of fast-moving microorganisms.
21 October 2025 in Nature Communications
We introduce super-resolution panoramic integration (SPI), an on-the-fly microscopy technique enabling instantaneous generation of subdiffractional images concurrently with scalable, high-throughput screening. SPI leverages multifocal optical rescaling, high-content sweeping, and synchronized linescan readout while preserving minimal post-processing and compatibility with epi-fluorescence settings. We demonstrate SPI for various subcellular and populational morphology, function, and heterogeneity. This versatile platform offers a practical pathway toward biological insights beyond traditional optical and computational constraints.
26 February 2024 in Ultrasound in Medicine & Biology
An adaptive harmonic separation (HS) technique is proposed to overcome the limitations in conventional filtering techniques for ultrasound (US) tissue harmonic imaging (THI). Based on expectation-maximization source separation, the proposed HS technique adaptively models the depth-varying fundamental and harmonic components in the frequency domain and separates the two by applying their calculated posterior probabilities. Phantom experiments with a Tx center frequency of 2 MHz are conducted to evaluate the proposed HS-based US THI schemes. The phantom images show that the proposed single-pulse THI scheme utilizing the HS technique provides not only an average improvement of 19.2% in axial resolution compared to the conventional bandpass filtering scheme but also similar image quality to that of the conventional pulse-inversion (PI) scheme which requires two Tx/Rx sequences for each scan line. Furthermore, when combined with the PI technique, the HS technique provides a uniform axial resolution over the entire 170 mm imaging depth with an average improvement of 17.1% compared to the conventional PI scheme. These results show that the proposed adaptive HS technique is capable of improving both the frame rate and the image quality of US THI.