Kyung Chul Lee

Kyung Chul Lee

Auto-generated profile, based on publicly available information

Kyung Chul Lee

Department of Mechanical Engineering, Seoul National University, Seoul, Republic of Korea

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2021 in ACS Photonics
Verified
Journal Article
Closed access
KLKyung Chul Lee
Kyung Chul Lee
KLKyungwon Lee
Kyungwon Lee
JJJaewoo Jung
Jaewoo Jung
SLSe Hee Lee
Se Hee Lee
DKDonghyun Kim
Donghyun Kim
SLSeung Ah Lee
Seung Ah Lee

1 March 2024 in Advanced Photonics
Verified
Journal Article
Open access
PDF file
SXShiqi Xu
Shiqi Xu
XYXi Yang
Xi Yang
PRPaul Ritter
Paul Ritter
XDXiang Dai
Xiang Dai
KLKyung Chul Lee
Kyung Chul Lee
RHRoarke Horstmeyer
Roarke Horstmeyer
Quantitative phase imaging (QPI) is a well-known label-free microscopy approach that can detect phase delay introduced by semitransparent cells and tissue.1 Due in part to its ability to provide quantitative information about primarily transparent biological specimens with low phototoxicity, QPI has become an invaluable tool in scientific and clinical studies, including for monitoring neuronal firing2 and cancer cell line detection,3 to name a few. Besides scalar phase contrast, transparent specimens also exhibit alternative and important endogenous optical contrast mechanisms, including anisotropic properties such as material birefringence and orientation. Indeed, the orientation of molecular arrangements in lipid membranes can now be quantitatively monitored with polarization-sensitive microscopes for studying multi-organelle interactive activities.4,5 There are naturally a variety of polarization-sensitive microscope arrangements, including early analog designs,6,7 differential interference contrast (DIC) methods,8 and contemporary digital approaches that reconstruct quantitative specimen retardance and orientation.9 – 11 These methods have been applied to study small model organisms12,13 and to assist clinical diagnosis.14 – 17

1 June 2023 in APL Photonics
Verified
Journal Article
Open access
PDF file
TKTaeyoung Kim
Taeyoung Kim
KLKyung Chul Lee
Kyung Chul Lee
NBNakkyu Baek
Nakkyu Baek
HCHyesuk Chae
Hyesuk Chae
SLSeung Ah Lee
Seung Ah Lee
We present a lensless snapshot hyperspectral camera that is capable of hyperspectral imaging over a broad spectrum using a compact and low-cost hardware configuration. We leverage the multiplexing capability of a lensless camera, a novel type of computational imaging device that replaces the lens with a thin mask. Our device utilizes a linear variable filter and a phase mask to encode spectral information onto a monochromatic image sensor, enabling recovery of hyperspectral image stacks from a single measurement by utilizing spectral information encoded in different parts of the 2D point spread function. We perform spectral calibration using a reference color chart and verify the prototype device’s spectral and spatial resolution, as well as its imaging field of view. We report on the design and construction of the device, the image reconstruction algorithm, and spectral calibration methods and present hyperspectral images ranging from 410 to 800 nm obtained with our prototype device.

1 April 2025 in Neurophotonics
Verified
Journal Article
Open access
LRLucas Kreiß Roohian
Lucas Kreiß Roohian
MWMelissa Wu
Melissa Wu
MWMichael Wayne
Michael Wayne
SXShiqi Xu
Shiqi Xu
PMPaul McKee
Paul McKee
RHRoarke Horstmeyer
Roarke Horstmeyer
SignificanceDiffuse correlation spectroscopy (DCS) allows label-free, non-invasive investigation of microvascular dynamics deep within tissue, such as cerebral blood flow (CBF). However, the signal-to-noise ratio (SNR) in DCS limits its effective cerebral sensitivity in adults, in which the depth to the brain, through the scalp and skull, is substantially larger than in infants.AimTherefore, we aim to increase its SNR and, ultimately, its sensitivity to CBF through new DCS techniques.ApproachWe present an in vivo demonstration of parallelized DCS (PDCS) to measure cerebral and muscular blood flow in healthy adults. Our setup employs an innovative array with hundreds of thousands single photon avalanche diodes (SPAD) in a 500×500 grid to boost SNR by averaging all independent pixel measurements. We tested this device on different total pixel counts and frame rates. A secondary, smaller array was used for reference measurements from shallower tissue at lower source-detector-separation (SDS).ResultsThe new system can measure pulsatile blood flow in cerebral and muscular tissue, at up to 4 cm SDS, while maintaining a similar measurement noise as compared with a previously published 32×32 PDCS system at 1.5 cm SDS. Data from a cohort of 15 adults provide strong experimental evidence for functional CBF activity during a cognitive memory task and allowed analysis of pulse markers. Additional control experiments on muscular blood flow in the forearm with a different technical configuration provide converging evidence for the efficacy of this technique.ConclusionsOur results outline successful PDCS measurements with large SPAD arrays to enable detect CBF in human adults. The ongoing development of SPAD camera technology is expected to result in larger and faster detectors in the future. In combination with new data processing techniques, tailored for the sparse signal of binary photon detection events in SPADs, this could lead to even greater SNR increase and ultimately greater depth sensitivity of PDCS.

5 May 2025 in Optica
Verified
Journal Article
Closed access
KZKevin C. Zhou
Kevin C. Zhou
CCClare Cook
Clare Cook
ACArchan Chakraborty
Archan Chakraborty
JBJennifer Bagwell
Jennifer Bagwell
JJJoakim Jönsson
Joakim Jönsson
RHRoarke Horstmeyer
Roarke Horstmeyer
Volumetric fluorescence imaging techniques, such as confocal, multiphoton, light sheet, and light field microscopy, have become indispensable tools across a wide range of cellular, developmental, and neurobiological applications. However, it is difficult to scale such techniques to the large 3D fields of view (FOV), volume rates, and synchronicity requirements for high-resolution 4D imaging of freely behaving organisms. Here, we present reflective Fourier light field computed tomography (ReFLeCT), a high-speed volumetric fluorescence computational imaging technique. ReFLeCT synchronously captures entire tomograms of multiple unrestrained, unanesthetized model organisms across multi-millimeter 3D FOVs at 120 volumes per second. In particular, we applied ReFLeCT to reconstruct 4D videos of fluorescently labeled zebrafish and Drosophila larvae, enabling us to study their heartbeat, fin and tail motion, gaze, jaw motion, and muscle contractions with nearly isotropic 3D resolution while they are freely moving. To our knowledge, as a novel approach for snapshot tomographic capture, ReFLeCT is a major advance toward bridging the gap between current volumetric fluorescence microscopy techniques and macroscopic behavioral imaging.

1 March 2025 in Applied Physics Letters
Verified
Journal Article
Open access
HYHansol Yoon
Hansol Yoon
HCHyesuk Chae
Hyesuk Chae
KLKyung Chul Lee
Kyung Chul Lee
KLKyungwon Lee
Kyungwon Lee
SLSeung Ah Lee
Seung Ah Lee
Fourier ptychography (FP) is widely adopted for label-free, high-resolution quantitative phase imaging (QPI) of biological samples. However, its imaging speed is limited by the need for multiple acquisitions. In this work, we propose a single-shot FP technique that uses linear polarizers to encode multiple illumination wavevectors and a polarization camera to capture multiple sets of information simultaneously. A multiplexed FP algorithm, utilizing both the bright-field and dark-field information, reconstructs a high-resolution quantitative phase image from the single-shot intensity image. Verified with resolution targets and a histological sample, our method achieved a resolution improvement of 2.5 times the diffraction limit of the objective lens and provided QPI over a large field-of-view. Additionally, we demonstrated high-speed FP at 75 frames per second, limited only by the sensor's readout speed, enabling QPI of fast-moving microorganisms.