1 October 1996 in Spectrochimica Acta Part B: Atomic Spectroscopy
9 August 2021 in Limnology and Oceanography: Methods
Phosphate in three seawater certified reference materials developed in previous work (NMIJ CRM 7601‐a, 7602‐a, and 7603‐a) was not certified because it was only determined by continuous flow analysis (CFA). To obtain certified values for phosphate, we developed a novel method for the analysis of phosphate in seawater via inductively coupled plasma sector field mass spectrometry (ICP‐SFMS) combined with anion exchange ion chromatography (IC). With use of a Jet‐sampler cone and an X‐skimmer cone on the ICP‐SFMS instrument, the 31P sensitivity derived from phosphate was enhanced by a factor of 18 compared to that of standard cones. To reduce the severe saline‐generated matrix effect, an IC with a switching‐valve system that separates phosphate from saline was employed. By adding an internal standard element (As) to the seawater samples, time‐dependent fluctuation of the 31P sensitivity was corrected and a better calibration curve was obtained. The developed method was applied to the analysis of three types of seawater. Although NMIJ CRM 7601‐a could not be determined because its concentration after dilution for the IC separation is lower than the detection limit (0.005 μmol kg−1), the analytical results for NMIJ CRM 7602‐a and 7603‐a are in good agreement with the values obtained via CFA, considering their expanded uncertainties with the coverage factor of 2. The developed method was validated by analyzing an existing certified reference material (MOOS‐3). This method enabled the measurement of sub‐μmol kg−1 levels of phosphate with high accuracy and sensitivity.
29 December 2021 in Bulletin of the Chemical Society of Japan
A certified reference material (CRM), i.e. NMIJ CRM 7204-a, was characterized for the analysis of 10 regulated trace elements in seawater sample, provided in 500 mL polyethylene bottle. Homogeneity and stability of the elements were investigated by inductively coupled plasma tandem quadrupole mass spectrometry after proper dilution, while mass-shift mode was applied to the measurement of trace elements except for Cd and Pb. A property value was obtained as the weighted mean of the results obtained by different methods with weights based on the reciprocal of the standard uncertainty. Combined uncertainty of a property value was obtained as the root mean square of the standard uncertainties of homogeneity, stability, analysis reproducibility, method-to-method variance, and calibrating standard. In NMIJ CRM 7204-a, the concentration of Cd is approximately 3 µg/kg, while those of other trace elements are around 10 µg/kg. Validity of the certified values was confirmed with analytical results of As and Cd by National Institute of Metrology (NIM, China) and those of Cd and Ni by Korea Research Institute of Standards and Science (KRISS, Korea). The concentrations of Na, Mg, K, and Ca along with the density values at 15, 20, and 25 degree Celsius were provided as information values.