This work reports the development and application of two liquid-core microstructured polymer optical fibers (LC-mPOF) with different microstructure sizes. They are used in a Fiber Enhanced Raman Spectroscopy (FERS) sensing platform, with the aim of detecting glucose in aqueous solutions in the clinically relevant range for sodium-glucose co-transporter 2 (SGLT2) inhibitor therapy. The sensing platform is tested for low concentration glucose solutions using each LC mPOF. Results confirm that a significant enhancement of the Raman signal is achieved in comparison to conventional Raman spectroscopy. Additional measurements are carried out to obtain the valid measurement range, the resolution, and the limit of detection, showing that the LC-mPOF with 66-μm-diameter central hollow core has the highest potential for future clinical applications. Finally, preliminary tests successfully demonstrate glucose identification in urine.
The characterization of the spectral emission and of the photostability of polymer optical fibers (POFs) doped with conjugated polymers has been carried out taking into account the distribution of the dopant in the fiber core. Four different conjugated polymers embedded in the matrix of the typical POF material have been analyzed. Measurements include, among others, evolutions of the emission with excitation wavelength and time, spectral changes for different excitation irradiances, and the influence of the propagation distance along the fiber.
In this work we have analyzed theoretically and experimentally the critical angle for the emission generated in doped polymer optical fibers as a function of different launching conditions by using the side-illumination fluorescence technique. A theoretical model has been developed in order to explain the experimental measurements. It is shown that both the theoretical and experimental critical angles are appreciably higher than the meridional critical angle corresponding to the maximum acceptance angle for a single source placed at the fiber axis. This increase changes the value of several important parameters in the performance of active fibers. The analysis has been performed in polymer optical fibers doped with a conjugated polymer.
One approach to overcome the poor efficiency of the Raman scattering as a sensing platform is to use microstructured optical fibers. In this type of fibers with a longitudinal holey structure, light interacts with the target sample, which is confined in the core, giving rise to a light intensity increase of the obtained Raman spectra due to the large interaction distances and the guidance of the scattered light. In this work, we present an ad-hoc fabricated liquid-core microstructured polymer optical fiber (LC-mPOF) as a bio-sensing platform for Raman Spectroscopy. Arising from an initial simulation stage, we create the desired preform using the drilling technique and afterwards the LC-mPOF is drawn in our fiber drawing tower. The guiding mechanism of the light through the solution has a major importance, being a key factor to obtain appreciable enhancements in Raman scattering. In this case, in order to optimize the Raman scattering signal of dissolved glucose (target molecule), we have filled the core with an aqueous solution of the target molecule, enabling in this way the modified total internal reflection mechanism. Experimental Raman measurements are performed and results are discussed.