Jinhui Zeng

Jinhui Zeng

Auto-generated profile, based on publicly available information

Jinhui Zeng

Hunan University of Technology

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2023 in Electronics
Verified
Journal Article
Open access
PDF file
JZJinhui Zeng
Jinhui Zeng
YWYisong Wu
Yisong Wu
JLJie Liu
Jie Liu
DHDong He
Dong He
ZLZheng Lan
Zheng Lan
Identifying critical nodes in the power grid is a crucial aspect of power system security and stability analysis. However, the current methods for identification fall short in fully accounting for the power transfer characteristics between nodes and the consequences of node removal on the security and stability of power grid operation. To enhance the effective and accurate identification of critical nodes in the power grid, a method is proposed. This method is based on improved PageRank algorithm and node-weighted power flow transfer entropy, referred to as IPRA-PFTE. Firstly, based on the power flow and equivalent impedance between nodes, and the introduction of virtual nodes, an improved PageRank algorithm is obtained. Then the node-weighted power flow transfer entropy is derived by considering the uniformity of the transfer power flow distribution in the system following the removal of a node. Finally, the importance of nodes is obtained by combining the improved PageRank algorithm with the node-weighted power flow transfer entropy. The method’s effectiveness and accuracy are validated through simulation using the IEEE 39-bus example and subsequent comparison with existing methods.

29 March 2023 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
JZJinhui Zeng
Jinhui Zeng
PWPin Wang
Pin Wang
HSHousheng Su
Housheng Su
CXChengjie Xu
Chengjie Xu
In this brief, consensus control is investigated for general linear multi-agent systems (MASs) over undirected communication topologies. Considering that the agents in MASs may have nonidentical intelligence characteristics, the concept of intelligent level is introduced to characterize the intelligence characteristics of agents. A novel dynamic event-triggered communication mechanism is developed based on periodic sampled data and the intelligent levels of agents, in which the threshold parameter of the event-triggered condition updates periodically in accordance with a prescribed dynamic law. By making use of a delayed system method and Lyapunov stability theory, some sufficient conditions are derived to guarantee the desired consensus under a novel delicately designed control protocol. Finally, the effectiveness of the proposed approach is validated by a simulation example.

2 May 2023 in International Journal of Control, Automation, and Systems
Verified
Journal Article
Closed access
PDF file
JZJinhui Zeng
Jinhui Zeng
PWPin Wang
Pin Wang
ZLZheng Lan
Zheng Lan
XLXueming Luo
Xueming Luo
JLJianghong Li
Jianghong Li
JHJiaxi Hu
Jiaxi Hu

9 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
JZJinhui Zeng
Jinhui Zeng
YRYao Rao
Yao Rao
ZLZheng Lan
Zheng Lan
DHDong He
Dong He
Fan XiaoFan Xiao
Fan Xiao
BLBei Liu
Bei Liu
To solve the problems of large current stress, difficult soft-switching of all switches, and slow dynamic response of dual active bridge converters, a multi-objective unified optimal control strategy based on triple-phase-shift control was proposed. The forward power flow global modes of triple-phase-shift control were analyzed, and three high-efficiency modes were selected to establish the analytical models of current stress and soft-switching. Combined with these models, the optimal solutions in different modes were derived by using the cost function-optimization equation to overcome the limitation of the Lagrange multiplier method, such that the DAB converter achieved the minimum current stress, and all switches operated in the soft-switching state over the entire power range. At the same time, the virtual power component was introduced in the phase-shift ratio combination, which improved the dynamic response of output voltage under the input voltage or load steps changed by power control. The theoretical analysis and experimental results show that the proposed control strategy can optimize the performance of the DAB converter from three aspects, such as current stress, soft-switching, and dynamic response, which achieves multi-objective optimization of the steady-state and dynamic performance of DAB converters.

14 August 2020 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
ZLZheng Lan
Zheng Lan
JWJunzhang Wang
Junzhang Wang
JZJinhui Zeng
Jinhui Zeng
DHDong He
Dong He
Fan XiaoFan Xiao
Fan Xiao
Fei JiangFei Jiang
Fei Jiang
In this paper, a constant frequency control strategy of a microgrid by coordinating energy router (ER) and energy storage system is proposed to solve the frequency fluctuation problem of microgrid, in which ER is the core of the energy management system. The interface converter of ER connected to the microgrid adopts the virtual synchronous generator (VSG) control, which adjusts the mechanical reference power in real time according to the state of charge (SOC) of the energy storage. The energy storage system adopts constant voltage and constant frequency (V/F) control to maintain the frequency and voltage stability of microgrid. The energy storage system with fast charge and discharge responds to the power fluctuation of the microgrid. ER maintains the stability of the energy storage capacity through bidirectional power regulation. When the energy storage system fails, the frequency and voltage droop characteristics of ER controlled by VSG will play a role in maintaining the stable operation of the microgrid. By the coordinating control strategy, the maximum efficiency of intermittent distributed energy can be guaranteed, and the stability, reliability, and grid-connection friendliness of the microgrid operation can be improved. Simulation results prove the effectiveness of the proposed control strategy.

24 September 2025 in Electronics
Verified
Journal Article
Open access
PDF file
BHBowen Huang
Bowen Huang
XXXueyuan Xie
Xueyuan Xie
JYJiangteng Yi
Jiangteng Yi
QYQian Yu
Qian Yu
YXYong Xu
Yong Xu
JLJie Liu
Jie Liu
Electrochemical energy storage technology, primarily lithium-ion batteries, has been widely applied in large-scale energy storage systems. However, differences in assembly structures, manufacturing processes, and operating environments introduce parameter inconsistencies among cells within a pack, producing complex, high-volume datasets with redundant and fragmented charge–discharge records that hinder efficient and accurate system monitoring. To address this challenge, we propose a hybrid ASW-UKF-TRF framework for the classification and compression of battery data collected from energy storage power stations. First, an adaptive sliding-window Unscented Kalman Filter (ASW-UKF) performs online data cleaning, imputation, and smoothing to ensure temporal consistency and recover missing/corrupted samples. Second, a temporally aware TRF segments the time series and applies an importance-weighted, multi-level compression that formally prioritizes diagnostically relevant features while compressing low-information segments. The novelty of this work lies in combining deployment-oriented engineering robustness with methodological innovation: the ASW-UKF provides context-aware, online consistency restoration, while the TRF compression formalizes diagnostic value in its retention objective. This hybrid design preserves transient fault signatures that are frequently removed by conventional smoothing or generic compressors, while also bounding computational overhead to enable online deployment. Experiments on real operational station data demonstrate classification accuracy above 95% and an overall data volume reduction in more than 60%, indicating that the proposed pipeline achieves substantial gains in monitoring reliability and storage efficiency compared to standard denoising-plus-generic-compression baselines. The result is a practical, scalable workflow that bridges algorithmic advances and engineering requirements for large-scale battery energy storage monitoring.