7 February 2026 in The European Physical Journal C
The use of gaseous Time Projection Chambers enables the detection and the detailed study of rare events due to particles interactions with the atoms of the gas with energy releases as low as a few keV. Due to this capability, these instruments are being developed for applications in the field of astroparticle physics, such as the study of dark matter and neutrinos. To acquire events occurring in the sensitive volume with a high granularity, the Cygno collaboration is developing a solution where the light generated during the avalanche processes occurring in a multiplication stage based on Gas Electron Multiplier (GEM) is read out by optical sensors with very high sensitivity and spatial resolution. To achieve a high light output, gas gain values of the order of $$10^5\text {-}10^6$$ are needed. In this working condition, a dependence of the detector response on the spatial density of the charge collected in the GEM holes has been observed, indicating a gain-reduction effect likely caused by space-charge buildup within the multiplication channels. This paper presents data collected with a prototype featuring a sensitive volume of about two liters, together with a model developed by the collaboration to describe and predict the gain dependence on charge density. A comparison with experimental data shows that the model reproduces, with a percent-level precision, the gain behaviour over nearly one order of magnitude.
6 November 2025 in The European Physical Journal C
The CYGNO experiment is developing a high-resolution gaseous Time Projection Chamber with optical readout for directional dark matter searches. The detector uses a helium-tetrafluoromethane (He:CF $$_4$$ 60:40) gas mixture at atmospheric pressure and a triple Gas Electron Multiplier amplification stage, coupled with a scientific camera for high-resolution 2D imaging and fast photomultipliers for time-resolved scintillation light detection. This setup enables 3D event reconstruction: photomultiplier signals provide depth information, while the camera delivers high-precision transverse resolution. In this work, we present a Bayesian Network-based algorithm designed to reconstruct the events using only the photomultiplier signals, inferring a 3D description of the particle trajectories. The algorithm models the light collection process probabilistically and estimates spatial and intensity parameters on the Gas Electron Multiplier plane, where light emission occurs. It is implemented within the Bayesian Analysis Toolkit and uses Markov Chain Monte Carlo sampling for posterior inference. Validation using data from the CYGNO LIME prototype shows accurate reconstruction of localized and extended straight tracks. Results demonstrate that the Bayesian approach enables robust 3D description and, when combined with camera data, opens the way to future improvements in spatial and energy resolution. This methodology represents a significant step forward in directional dark matter detection, enhancing the identification of nuclear recoil tracks with high spatial resolution.
1 April 2026 in Machine Learning: Science and Technology
Optical-readout time projection chambers (TPCs) produce megapixel-scale images whose fine-grained topological information is essential for rare-event searches, but whose size challenges real-time data selection. We present an unsupervised, reconstruction-based anomaly-detection strategy for fast region-of-interest (ROI) extraction that operates directly on minimally processed camera frames. A convolutional autoencoder (AE) trained exclusively on pedestal images learns the detector noise morphology without labels, simulation, or fine-grained calibration. Applied to standard data-taking frames, localized reconstruction residuals identify particle-induced structures, from which compact ROIs are extracted via thresholding and spatial clustering. Using real data from the CYGNO optical TPC prototype, we compare two pedestal-trained AE configurations that differ only in their training objective, enabling a controlled study of its impact. The best configuration retains of reconstructed signal intensity while discarding of the image area, with an inference time of ∼25 ms per frame on a consumer GPU. The results demonstrate that careful design of the training objective is critical for effective reconstruction-based anomaly detection and that pedestal-trained AEs provide a transparent and detector-agnostic baseline for online data reduction in optical TPCs.
1 September 2026 in Journal of Instrumentation
Dark matter, which is considered to account for approximately the 27% of the Universe's energy-mass content, remains an open issue in modern particle physics along with its composition. The CYGNO Experiment aims to exploit an innovative approach applied to the direct detection search of low energy nuclear recoils possibly induced by cold particle-like dark matter candidates. CYGNO employs a directional detector based on a Time Projection Chamber (TPC) filled with a He:CF 4 gas mixture and equipped with an optical readout. Currently, the CYGNO Collaboration is constructing the detector demonstrator, CYGNO-04, in Hall F at Laboratori Nazionali del Gran Sasso (LNGS). This 0.4 m 3 detector has the goal of proving the scalability of the technology and assessing the physics and radiopurity capabilities. Given the low radioactivity requirements, especially in internal components such as field cage and cathode, the reduction of material while keeping the correct electrical behavior is paramount. In this paper, we present the validation of several internal components, mainly focusing on the field cage material and support structure. The tests included geometrical asymmetries in the electric field response, collection efficiency as well as measurement of known physical quantities. A preferred configuration is found with a structure based on Nylon material which supports a PET or Kapton sheet with copper strips deposited on.
24 September 2026 in Measurement Science and Technology
Time projection chambers equipped with gas electron multipliers and optical readout by scientific CMOS cameras are a promising technology for low-energy particle detection, as demonstrated by the CYGNO experiment. To help identify an optimal detector configuration, we performed a characterization of two state-of-the-art CMOS sensors focusing on dark signal behavior across different exposure times and on detection sensitivity, assessed using the x-ray emissions from a Fe radioactive source, reproducing the low-light conditions expected in the experiment. CYGNO currently employs a low-noise ORCA-Fusion sensor produced by Hamamatsu for validation of its detection system. However, Hamamatsu has introduced two new sensors that could be of interest for future upgrades. The first is an upgraded model of the current sensor, the ORCA-Fusion-BT, featuring a back-illuminated design that reaches a quantum efficiency of up to 95% at 550 nm. The second is a next-generation sensor referred to as the ORCA-Quest. While its peak quantum efficiency is not as high as that of the ORCA-Fusion-BT, it offers high sensitivity across a broader spectral range, extending into the ultraviolet region, and delivers ultra-low readout noise of 0.27 electrons, about 2.6 times lower than that of the Fusion family. These sensors therefore represent an opportunity to enhance the performance of experiments, including those conducted by the CYGNO collaboration. This document presents a characterization of these sensors to evaluate their relevance in photon-limited environments and their suitability for integration into the CYGNO detector system.
1 April 2026 in Journal of Instrumentation
The CYGNO experiment employs an optical readout to image particle interactions in a gaseous Time Projection Chamber (TPC), combining cameras and photomultiplier tubes (PMTs) to achieve high spatial resolution and timing information. This approach enables detailed track reconstruction but poses significant challenges for data acquisition, particularly in view of the next experimental phase, CYGNO-04, which will operate multiple cameras simultaneously. In this paper, we present an upgrade of the CYGNO Trigger and Data Acquisition (T-DAQ) system, developed starting from the LIME configuration and validated on the MANGO prototype. The upgrade introduces a continuous imaging acquisition mode, substantially reducing the camera dead time, together with an extended trigger time-tagging scheme that provides a robust global time reference for PMT signals. A synchronous multi-camera DAQ architecture is also implemented and tested, enabling coordinated operation of multiple optical sensors without a master camera. The performance of the upgraded system is validated through dedicated tests, demonstrating stable continuous acquisition, reliable time-tagging, and consistent synchronization across multiple cameras. These results establish a solid and scalable foundation for the CYGNO-04 DAQ and represent a key step toward efficient data acquisition in future large-scale optical TPC detectors.