13 June 2022 in Physics in Medicine & Biology
Objective . Dose distribution data plays a pivotal role in radiotherapy treatment planning. The data is typically represented using voxel grids, and its size ranges from 10 6 to 10 8 . A concise representation of the treatment plan is of great value in facilitating treatment planning and downstream applications. This work aims to develop an implicit neural representation of 3D dose distribution data. Approach . Instead of storing the dose values at each voxel, in the proposed approach, the weights of a multilayer perceptron (MLP) are employed to characterize the dosimetric data for plan representation and subsequent applications. We train a coordinate-based MLP with sinusoidal activations to map the voxel spatial coordinates to the corresponding dose values. We identify the best architecture for a given parameter budget and use that to train a model for each patient. The trained MLP is evaluated at each voxel location to reconstruct the dose distribution. We perform extensive experiments on dose distributions of prostate, spine, and head and neck tumor cases to evaluate the quality of the proposed representation. We also study the change in representation quality by varying model size and activation function. Main results . Using coordinate-based MLPs with sinusoidal activations, we can learn implicit representations that achieve a mean-squared error of 10 −6 and peak signal-to-noise ratio greater than 50 dB at a target bitrate of ∼1 across all the datasets, with a compression ratio of ∼32. Our results also show that model sizes with a bitrate of 1–2 achieve optimal accuracy. For smaller bitrates, performance starts to drop significantly. Significance . The proposed model provides a low-dimensional, implicit, and continuous representation of 3D dose data. In summary, given a dose distribution, we systematically show how to find a compact model to fit the data accurately. This study lays the groundwork for future applications of neural representations of dose data in radiation oncology.
3 March 2022 in Physics in Medicine & Biology
Objective . Radiation therapy treatment planning is a time-consuming process involving iterative adjustments of hyperparameters. To automate the treatment planning process, we propose a meta-optimization framework, called MetaPlanner (MP). Approach . Our MP algorithm automates planning by performing meta-optimization of treatment planning hyperparameters. The algorithm uses a derivative-free method (i.e. parallel Nelder–Mead simplex search) to search for weight configurations that minimize a meta-scoring function. Meta-scoring is performed by constructing a tier list of the relevant considerations (e.g. dose homogeneity, conformity, spillage, and OAR sparing) to mimic the clinical decision-making process. Additionally, we have made our source code publicly available via github. Main results . The proposed MP method is evaluated on two datasets (21 prostate cases and 6 head and neck cases) collected as part of clinical workflow. MP is applied to both IMRT and VMAT planning and compared to a baseline of manual VMAT plans. MP in both IMRT and VMAT scenarios has comparable or better performance than manual VMAT planning for all evaluated metrics. Significance . Our proposed MP provides a general framework for fully automated treatment planning that produces high quality treatment plans. Our MP method promises to substantially reduce the workload of treatment planners while maintaining or improving plan quality.
20 September 2021 in IEEE Transactions on Biomedical Engineering
Objective: Radiation therapy treatment planning is a time-consuming, iterative process with potentially high inter-planner variability. Fully automated treatment planning processes could reduce a planner's active treatment planning time and remove inter-planner variability, with the potential to tremendously improve patient turnover and quality of care. In developing fully automated algorithms for treatment planning, we have two main objectives: to produce plans that are 1) Pareto optimal and 2) clinically acceptable. Here, we propose the Pareto optimal projection search (POPS) algorithm, which provides a general framework for directly searching the Pareto front. Methods: Our POPS algorithm is a novel automated planning method that combines two main search processes: 1) gradient-free search in the decision variable space and 2) projection of decision variables to the Pareto front using the bisection method. We demonstrate the performance of POPS by comparing with clinical treatment plans. As one possible quantitative measure of treatment plan quality, we construct a clinical acceptability scoring function (SF) modified from the previously developed general evaluation metric (GEM). Results: On a dataset of 21 prostate cases collected as part of clinical workflow, our proposed POPS algorithm produces Pareto optimal plans that are clinically acceptable in regards to dose conformity, dose homogeneity, and sparing of organs-at-risk. Conclusion: Our proposed POPS algorithm provides a general framework for fully automated treatment planning that achieves clinically acceptable dosimetric quality without requiring active planning from human planners. Significance: Our fully automated POPS algorithm addresses many key limitations of other automated planning approaches, and we anticipate that it will substantially improve treatment planning workflow.
14 September 2021 in Medical Physics
3 May 2023 in Physics in Medicine & Biology
Objective. In this work, we propose a content-based image retrieval (CBIR) method for retrieving dose distributions of previously planned patients based on anatomical similarity. Retrieved dose distributions from this method can be incorporated into automated treatment planning workflows in order to streamline the iterative planning process. As CBIR has not yet been applied to treatment planning, our work seeks to understand which current machine learning models are most viable in this context. Approach. Our proposed CBIR method trains a representation model that produces latent space embeddings of a patient’s anatomical information. The latent space embeddings of new patients are then compared against those of previous patients in a database for image retrieval of dose distributions. All source code for this project is available on github. Main results. The retrieval performance of various CBIR methods is evaluated on a dataset consisting of both publicly available image sets and clinical image sets from our institution. This study compares various encoding methods, ranging from simple autoencoders to more recent Siamese networks like SimSiam, and the best performance was observed for the multitask Siamese network. Significance. Our current results demonstrate that excellent image retrieval performance can be obtained through slight changes to previously developed Siamese networks. We hope to integrate CBIR into automated planning workflow in future works.
1 November 2021 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)