Joseph Woods

Joseph Woods

Auto-generated profile, based on publicly available information

Joseph Woods

Oxford Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences University of Oxford Oxford UK

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
LHLuis Hernandez‐Garcia
Luis Hernandez‐Garcia
VAVerónica Aramendía‐Vidaurreta
Verónica Aramendía‐Vidaurreta
DBDivya S. Bolar
Divya S. Bolar
WDWeiying Dai
Weiying Dai
MFMaría. A. Fernández-Seara
María. A. Fernández-Seara
TOThomas W. Okell
Thomas W. Okell
This review article provides an overview of a range of recent technical developments in advanced arterial spin labeling (ASL) methods that have been developed or adopted by the community since the publication of a previous ASL consensus paper by Alsop et al. It is part of a series of review/recommendation papers from the International Society for Magnetic Resonance in Medicine Perfusion Study Group. Here, we focus on advancements in readouts and trajectories, image reconstruction, noise reduction, partial volume correction, quantification of nonperfusion parameters, fMRI, fingerprinting, vessel selective ASL, angiography, deep learning, and ultrahigh field ASL. We aim to provide a high level of understanding of these new approaches and some guidance for their implementation, with the goal of facilitating the adoption of such advances by research groups and by MRI vendors. Topics outside the scope of this article that are reviewed at length in separate articles include velocity selective ASL, multiple‐timepoint ASL, body ASL, and clinical ASL recommendations.

9 April 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
JWJoseph G. Woods
Joseph G. Woods
EAEric Achten
Eric Achten
IAIris Asllani
Iris Asllani
DBDivya S. Bolar
Divya S. Bolar
WDWeiying Dai
Weiying Dai
TGthe ISMRM Perfusion Study Group
the ISMRM Perfusion Study Group
Accurate assessment of cerebral perfusion is vital for understanding the hemodynamic processes involved in various neurological disorders and guiding clinical decision‐making. This guidelines article provides a comprehensive overview of quantitative perfusion imaging of the brain using multi‐timepoint arterial spin labeling (ASL), along with recommendations for its acquisition and quantification. A major benefit of acquiring ASL data with multiple label durations and/or post‐labeling delays (PLDs) is being able to account for the effect of variable arterial transit time (ATT) on quantitative perfusion values and additionally visualize the spatial pattern of ATT itself, providing valuable clinical insights. Although multi‐timepoint data can be acquired in the same scan time as single‐PLD data with comparable perfusion measurement precision, its acquisition and postprocessing presents challenges beyond single‐PLD ASL, impeding widespread adoption. Building upon the 2015 ASL consensus article, this work highlights the protocol distinctions specific to multi‐timepoint ASL and provides robust recommendations for acquiring high‐quality data. Additionally, we propose an extended quantification model based on the 2015 consensus model and discuss relevant postprocessing options to enhance the analysis of multi‐timepoint ASL data. Furthermore, we review the potential clinical applications where multi‐timepoint ASL is expected to offer significant benefits. This article is part of a series published by the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group, aiming to guide and inspire the advancement and utilization of ASL beyond the scope of the 2015 consensus article.

12 July 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
QQQin Qin
Qin Qin
DADavid C. Alsop
David C. Alsop
DBDivya S. Bolar
Divya S. Bolar
LHLuis Hernandez‐Garcia
Luis Hernandez‐Garcia
JMJames Meakin
James Meakin
TGthe ISMRMPerfusion Study Group
the ISMRMPerfusion Study Group
This review article provides an overview of the current status of velocity‐selective arterial spin labeling (VSASL) perfusion MRI and is part of a wider effort arising from the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group. Since publication of the 2015 consensus paper on arterial spin labeling (ASL) for cerebral perfusion imaging, important advancements have been made in the field. The ASL community has, therefore, decided to provide an extended perspective on various aspects of technical development and application. Because VSASL has the potential to become a principal ASL method because of its unique advantages over traditional approaches, an in‐depth discussion was warranted. VSASL labels blood based on its velocity and creates a magnetic bolus immediately proximal to the microvasculature within the imaging volume. VSASL is, therefore, insensitive to transit delay effects, in contrast to spatially selective pulsed and (pseudo‐) continuous ASL approaches. Recent technical developments have improved the robustness and the labeling efficiency of VSASL, making it a potentially more favorable ASL approach in a wide range of applications where transit delay effects are of concern. In this review article, we (1) describe the concepts and theoretical basis of VSASL; (2) describe different variants of VSASL and their implementation; (3) provide recommended parameters and practices for clinical adoption; (4) describe challenges in developing and implementing VSASL; and (5) describe its current applications. As VSASL continues to undergo rapid development, the focus of this review is to summarize the fundamental concepts of VSASL, describe existing VSASL techniques and applications, and provide recommendations to help the clinical community adopt VSASL.

26 December 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
JWJoseph G. Woods
Joseph G. Woods
MCMichael A. Chappell
Michael A. Chappell
TOThomas W. Okell
Thomas W. Okell
Purpose: Arterial spin labeling (ASL) MRI is a non‐invasive perfusion imaging technique that is inherently SNR limited, so scan protocols ideally need to be rigorously optimized to provide the most accurate measurements. A general framework is presented for optimizing ASL experiments to achieve optimal accuracy for perfusion estimates and, if required, other hemodynamic parameters, within a fixed scan time. The effectiveness of this framework is then demonstrated by optimizing the post‐labeling delays (PLDs) of a multi‐PLD pseudo‐continuous ASL experiment and validating the improvement using simulations and in vivo data.Theory and Methods: A simple framework is proposed based on the use of the Cramér‐Rao lower bound to find the protocol design which minimizes the predicted parameter estimation errors. Protocols were optimized for cerebral blood flow (CBF) accuracy or both CBF and arterial transit time (ATT) accuracy and compared to a conventional multi‐PLD protocol, with evenly spaced PLDs, and a single‐PLD protocol, using simulations and in vivo experiments in healthy volunteers.Results: Simulations and in vivo data agreed extremely well with the predicted performance of all protocols. For the in vivo experiments, optimizing for just CBF resulted in a 48% and 15% decrease in CBF errors, relative to the reference multi‐PLD and single‐PLD protocols, respectively. Optimizing for both CBF and ATT reduced CBF errors by 37%, without a reduction in ATT accuracy, relative to the reference multi‐PLD protocol.Conclusion: The presented framework can effectively design ASL experiments to minimize measurement errors based on the requirements of the scan.

1 December 2020 in NeuroImage
Verified
Journal Article
Open access
JWJoseph G. Woods
Joseph G. Woods
MCMichael A. Chappell
Michael A. Chappell
TOThomas W. Okell
Thomas W. Okell
Arterial Spin Labeling (ASL) is a non-invasive, non-contrast, perfusion imaging technique which is inherently SNR limited. It is, therefore, important to carefully design scan protocols to ensure accurate measurements. Many pseudo-continuous ASL (PCASL) protocol designs have been proposed for measuring cerebral blood flow (CBF), but it has not yet been demonstrated which design offers the most accurate and repeatable CBF measurements. In this study, a wide range of literature PCASL protocols were first optimized for CBF accuracy and then compared using Monte Carlo simulations and in vivo experiments. The protocols included single-delay, sequential and time-encoded multi-timepoint protocols, and several novel protocol designs, which are hybrids of time-encoded and sequential multi-timepoint protocols. It was found that several multi-timepoint protocols produced more confident, accurate, and repeatable CBF estimates than the single-delay protocol, while also generating maps of arterial transit time. Of the literature protocols, the time-encoded protocol with T1-adjusted label durations gave the most confident and accurate CBF estimates in vivo (16% and 40% better than single-delay), while the sequential multi-timepoint protocol was the most repeatable (20% more repeatable than single-delay). One of the novel hybrid protocols, HybridT1-adj, was found to produce the most confident, accurate and repeatable CBF estimates out of all the protocols tested in both simulations and in vivo (24%, 47%, and 28% more confident, accurate, and repeatable than single-delay in vivo). The HybridT1-adj protocol makes use of the best aspects of both time-encoded and sequential multi-timepoint protocols and should be a useful tool for accurately and efficiently measuring CBF.

6 September 2022 in Scientific Data
Verified
Journal Article
Open access
PDF file
PCPatricia Clement
Patricia Clement
MCMarco Castellaro
Marco Castellaro
TOThomas W. Okell
Thomas W. Okell
DTDavid L. Thomas
David L. Thomas
PVPieter Vandemaele
Pieter Vandemaele
HMHenk Mutsaerts
Henk Mutsaerts
Arterial spin labeling (ASL) is a non-invasive MRI technique that allows for quantitative measurement of cerebral perfusion. Incomplete or inaccurate reporting of acquisition parameters complicates quantification, analysis, and sharing of ASL data, particularly for studies across multiple sites, platforms, and ASL methods. There is a strong need for standardization of ASL data storage, including acquisition metadata. Recently, ASL-BIDS, the BIDS extension for ASL, was developed and released in BIDS 1.5.0. This manuscript provides an overview of the development and design choices of this first ASL-BIDS extension, which is mainly aimed at clinical ASL applications. Discussed are the structure of the ASL data, focussing on storage order of the ASL time series and implementation of calibration approaches, unit scaling, ASL-related BIDS fields, and storage of the labeling plane information. Additionally, an overview of ASL-BIDS compatible conversion and ASL analysis software and ASL example datasets in BIDS format is provided. We anticipate that large-scale adoption of ASL-BIDS will improve the reproducibility of ASL research.