Tina Ebert

Tina Ebert

Auto-generated profile, based on publicly available information

Tina Ebert

Lawrence Livermore National Laboratory 1 , 7000 East Avenue, Livermore, California 94551

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2022 in Nature Communications
Verified
Journal Article
Open access
PDF file
MZMarc Zimmer
Marc Zimmer
SSStefan Scheuren
Stefan Scheuren
AKAnnika Kleinschmidt
Annika Kleinschmidt
NMNikodem Mitura
Nikodem Mitura
ATAlexandra Tebartz
Alexandra Tebartz
MRMarkus Roth
Markus Roth
Neutrons are a valuable tool for non-destructive material investigation as their interaction cross sections with matter are isotope sensitive and can be used complementary to x-rays. So far, most neutron applications have been limited to large-scale facilities such as nuclear research reactors, spallation sources, and accelerator-driven neutron sources. Here we show the design and optimization of a laser-driven neutron source in the epi-thermal and thermal energy range, which is used for non-invasive material analysis. Neutron resonance spectroscopy, neutron radiography, and neutron resonance imaging with moderated neutrons are demonstrated for investigating samples in terms of isotope composition and thickness. The experimental results encourage applications in non-destructive and isotope-sensitive material analysis and pave the way for compact laser-driven neutron sources with high application potential.

24 May 2021 in High Power Laser Science and Engineering
Verified
Journal Article
Open access
PDF file
TETina Ebert
Tina Ebert
RHRené Heber
René Heber
TATorsten Abel
Torsten Abel
JBJohannes Bieker
Johannes Bieker
GSGabriel Schaumann
Gabriel Schaumann
MRMarkus Roth
Markus Roth
Targets with microstructured front surfaces have shown great potential in improving high-intensity laser–matter interaction. We present cone-shaped microstructures made out of silicon and titanium created by ultrashort laser pulse processing with different characteristics. In addition, we illustrate a process chain based on moulding to recreate the laser-processed samples out of polydimethylsiloxane, polystyrol and copper. With all described methods, samples of large sizes can be manufactured, therefore allowing time-efficient, cost-reduced and reliable ways to fabricate large quantities of identical targets.

1 April 2020 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
TETina Ebert
Tina Ebert
NNNico W. Neumann
Nico W. Neumann
LDLeonard N. K. Döhl
Leonard N. K. Döhl
JJJonathan Jarrett
Jonathan Jarrett
CBChristopher Baird
Christopher Baird
MRMarkus Roth
Markus Roth
The production of intense x-ray and particle sources is one of the most remarkable aspects of high energy laser interaction with a solid target. Wide application of these laser-driven secondary sources requires a high yield, which is partially limited by the amount of laser energy absorbed by the target. Here, we report on the enhancement of laser absorption and x-ray and particle flux by target surface modifications. In comparison to targets with flat front surfaces, our experiments show exceptional laser-to-target performance for our novel cone-shaped silicon microstructures. The structures are manufactured via laser-induced surface structuring. Spectral and spatial studies of reflectance and x-ray generation reveal significant increases of the silicon Kα line and a boost of the overall x-ray intensity, while the amount of reflected light decreases. Also, the proton and electron yields are enhanced, but both temperatures remain comparable to those of flat foil targets. We support the experimental findings with 2D particle in cell simulations to identify the mechanisms responsible for the strong enhancement. Our results demonstrate how custom surface structures can be used to engineer high power laser-plasma sources for future applications.

1 February 2024 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
GHG. N. Hall
G. N. Hall
CWC. R. Weber
C. R. Weber
VSV. A. Smalyuk
V. A. Smalyuk
OLO. L. Landen
O. L. Landen
CTC. Trosseille
C. Trosseille
JHJ. P. Holder
J. P. Holder
The interface between the capsule ablator and fuel ice layer is susceptible to hydrodynamic instabilities. The subsequent mixing of hot ablator material into the ice reduces fuel compression at stagnation and is a candidate for reduced capsule performance. The ability to diagnose ice–ablator mix is critical to understanding and improving stability at this interface. Combining the crystal backlighter imager with the single line of sight camera on the National Ignition Facility (NIF) allows direct measurement of ice–ablator mix by providing multiple quasi-monochromatic radiographs of layered capsule implosions per experiment with high spatial (∼12 μm) and temporal (∼35 ps) resolution. The narrow bandwidth of this diagnostic platform allows radiography of the inner edge of the capsule limb close to stagnation without capsule self-emission contaminating the data and removes opacity uncertainties typically associated with the spectral content of the radiograph. Analysis of radiographic data via a parameterized forward-fitting Abel inversion technique provides measurements of the distribution of mix mass inwards from the ice–ablator interface. The sensitivity of this mix measurement technique was demonstrated by applying it to layered experiments in which the stability of the ice–ablator interface was expected to vary significantly. Additional experiments suggest that high-density carbon capsules that employ a buried-layer dopant profile suffer from mixing at the innermost doped–undoped interface. Data from these experiments suggest that opacity models used in hydrodynamic simulations of NIF experiments can potentially over-predict the opacity of doped capsules. LLNL-JRNL-850535-DRAFT.

1 September 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
MHM. Hesse
M. Hesse
TET. Ebert
T. Ebert
MZM. Zimmer
M. Zimmer
SSStefan Scheuren
Stefan Scheuren
GSG. Schaumann
G. Schaumann
MRM. Roth
M. Roth
Laser-based particle accelerators have been an active field of research for over two decades moving from laser systems capable of one shot every hour to systems able to deliver repetition rates in the Hz regime. Based on the advancements in laser technology, the corresponding detection methods need to develop from single to multiple use with high readout speed. Here, we present an online compact tracker of particles using scintillators with nine resolvable energy levels and a spatial resolution of 3.6 × 3.6 mm2 over the whole active area. This paper describes the design and construction of the detector, which is based on pixellated scintillators embedded inside an absorber matrix. The scintillator pixels are fiberoptically coupled to a camera system for online readout and analysis. Calibration with a radioactive source and first experimental data measuring laser accelerated ions at the PHELIX laser at GSI, Darmstadt, Germany, are presented and discussed.

27 December 2021 in Physical Review E
Verified
Journal Article
Closed access
PDF file
SSS. Sander
S. Sander
TET. Ebert
T. Ebert
DHD. Hartnagel
D. Hartnagel
MHM. Hesse
M. Hesse
XPX. Pan
X. Pan
MRM. Roth
M. Roth
We present the usage of two-layer targets with laser-illuminated front-side microstructures for x-ray backlighter applications. The targets consisted of a silicon front layer and copper back side layer. The structured layer was irradiated by the 500-fs PHELIX laser with an intensity above 1020Wcm−2. The total emission and one-dimensional extent of the copper Kα x-ray emission as well as a wide spectral range between 7.9 and 9.0 keV were recorded with an array of crystal spectrometers. The measurements show that the front-side modifications of the silicon in the form of conical microstructures maintain the same peak brightness of the Kα emission as flat copper foils while suppressing the thermal emission background significantly. The observed Kα source sizes can be influenced by tilting the conical microstructures with respect to the laser axis. Overall, the recorded copper Kα photon yields were in the range of 1011sr−1, demonstrating the suitability of these targets for probing applications without subjecting the probed material to additional heating from thermal line emission.